Preview | There are 132 results for | Relevancy |
BAMO acquires a German Company News () To confirm its activities development on fluids control, BAMO Mesures SAS acquires the First of January 2006 the well-known Company IER Mess und Regeltechnik GmbH. IER in a few words: 35 years of experience in the German Market Turn over of 2 millions... Created on 21/12/2009 17:09 and updated on 10/04/2018 16:24 |
News |
RDP 906 Pressure reducing valves Page (906-02) A pressure reducing valve RDP 906 maintains constant the pressure downstream, at the adjusted value. Pressure: Class PN 10 (at 20°C) Set up range: 1 to 9 bar Temperature limits PPH: 10 to 70°C PVC: 10 to 50°C Dimensions: ND 10 ... ND 25 Body: PPG... Created on 15/03/2011 11:10 and updated on 10/04/2018 14:36 |
906-02 Page |
VP3V S4-PPH Pneumatically actuated 3-way ball valves, single / double acting Starting Up Notice (913-05)
Created on 12/12/2011 17:33 and updated on 10/04/2018 16:03 |
913-05 Starting Up Notice |
Achema 2012 World Exhibition Congress on Chemical Engineering, Environmental Protection and Biotechnology News () 18 - 22 June Hall 11, booth G3 We show off our complete range and all our new products on our booth BAMO-IER GmbH. Relevant lines: New series MAXIMAT CX, certification acc.WHG§19 TRUBOMAT: complete line for turbidity monitoring SDD and RDP new lines of... Created on 04/04/2012 20:10 and updated on 10/04/2018 16:19 |
News |
BAMOPORT MI 415 Handheld turbidity-meter Page (448-02) • Measuring scales: 0.50 to 50 FNU 50 to 1000 FNU • Easy to use • Supplied ready-to-use with a rigid case Created on 10/12/2019 16:02 and updated on 10/12/2019 16:08 |
448-02 Page |
OPTIFLUX ECFV Flow indicator Page (719-02) • Direct view of the flow of a liquid • Vertical or horizontal mounting • Ranges up to 60 I/min • Fittings: ¼"... 1" BSP F. • Body: Nickel-plated brass Created on 17/12/2019 10:45 and updated on 17/12/2019 10:56 |
719-02 Page |
VM2V S4 FDC Manually operated 2-way ball valves and limit switches Page (934-03) • Radial mounting and dismounting • 100 % full flow • 2 limit switches Created on 18/12/2019 15:43 and updated on 18/12/2019 15:54 |
934-03 Page |
BSM 501 - BSM 515 Level switches with micro-switch Page (585-01) High power switching Reverse and bi-stable switch IP 65 housing • High switching power • Bistable switch • Protection: IP 65 Created on 10/10/2006 17:10 and updated on 11/12/2019 15:31 |
585-01 Page |
EF / EFC Level electrodes for wells Page (542-02) For well and bore-hole Compactness Material: Stainless steel • Compact electrodes • All stainless steel • For conductive liquids • Supplied with or without cable Created on 13/06/2007 14:15 and updated on 11/12/2019 13:23 |
542-02 Page |
TS 11 Temperature probe with Pt 100 Ω sensor Page (611-01) Pt 100 Ω at 0 °C Measure scale Wetted parts S.Steel Industrial head • Sensor Pt 100 Ω at 0 °C • Range from -50 to +250 °C • Stem and fitting in AISI 316 L • Head in aluminum alloy or in plastic Created on 20/12/2007 09:58 and updated on 11/12/2019 16:37 |
611-01 Page |
ES 5000 Relay for resistive level detection Starting Up Notice (544-06)
Created on 04/02/2009 18:25 and updated on 10/04/2018 15:40 |
544-06 Starting Up Notice |
J.A.R. Heavy-duty Cat & Mouse level indicator News () So many technologies such as radars, ultrasonic transmitters, are offering sophisticated measuring systems that do not answer to simple requests! This is an opportunity for BAMO to redesign a level indicator. A strong experience helped us to build up... Created on 22/12/2009 14:59 and updated on 10/04/2018 16:20 |
News |
WP7 Hydrogen peroxide sensor Page (193-25) For swimming pool water, drinkable water, cooling water, process water Range: from 0.001 up to 100.0 g/L Output signal: 4-20 mA Sensor affords surfactants Pressure limit: 1 bar as a maximum Unnecessary zero adjustment Created on 26/11/2010 16:34 and updated on 10/04/2018 13:42 |
193-25 Page |
AQUAPLUS Dissolved oxygen probe Page (451-01) Measuring up to 50 mg/l or up to 500% in saturation Numeric signal compensated in temperature and salinity Low maintenance No water flow required Interference free towards suspended solids AQUAPLUS™ Probe holder PVC tube Ø 50 Standard length 2... Created on 18/11/2011 15:43 and updated on 10/12/2019 16:14 |
451-01 Page |
NIVOSTOP SS2 W & KW Switch level floats Starting Up Notice (520-01)
Created on 21/02/2012 13:11 and updated on 10/04/2018 15:35 |
520-01 Starting Up Notice |
ClO₂⁺ Photometer for chlorine and chlorine dioxide Page (190-12) • For drinking water and hot water networks • Concentration of free chlorine, total chlorine and chlorine dioxide • Measurement ranges: Chlorine from 0.01 to 5 mg/l Chlorine dioxide from 0.02 to 10 mg/l • Supplied ready to use Created on 04/12/2019 14:21 and updated on 04/12/2019 14:33 |
190-12 Page |
GNR5 - Glass reading tube Level indicator Page (570-01) • Direct reading on the tank • Height from 300 up to 2000 mm • Materials: Glass and brass • Seals: Silicon rubber • Option: Adjustable level contacts Created on 11/12/2019 13:47 and updated on 11/12/2019 13:50 |
570-01 Page |
DUG Flow controller with indicator, metallic Page (725-02) • Operates in all positions • Indicator, plus 1 adjustable contact • Versions: Stainless steel or brass • Pressure up to 10 bar • Flow range: 0.2 ... 250 l/min Created on 17/12/2019 14:48 and updated on 17/12/2019 14:55 |
725-02 Page |
BAMOCHLOR 192 Open Cell Free chlorine assembly for swimming pools Page (192-01) Opened cell, copper / platinum For swimming pool Free active chlorine monitoring Range: 0 to 5 ppm For BAMOPHOX 192 Pressure limit: 0.2 bar Temperature limit: 0...40 °C Self cleaning Open cell amperometric method Electrochemical cell Self cleaning... Created on 09/10/2006 10:41 and updated on 10/04/2018 13:38 |
192-01 Page |
EVEREST 214 2 channels measuring amplifier for 0/4-20 mA sensors Page (232-03) 4 Limit value Relays for 1 or/and 2 input signal The forth relay may be used as a Timer Adjustable hysteresis 2 inputs 4-20 mA, scalable from 0 to 25 mA Power supply to the sensors Created on 28/06/2007 15:42 and updated on 10/04/2018 13:46 |
232-03 Page |
BamoPHOX TOR 322 E - M Conductivity meter, scales: 0 ...2 /...20 /...200 /...2000 mS Starting Up Notice (322-03)
Created on 26/06/2008 15:04 and updated on 10/04/2018 15:29 |
322-03 Starting Up Notice |
ITU 402 - ITU 412 Panel mounting indicators Page (222-03) Inputs: mA, V, Pt 100, Ni 100, TC Main power input: 21.6...253 VAC / 50-60 Hz or 19.2...300 VDC Sensor power supply: 15...25 VDC / 0...20 mA Housing: IP65, black polycarbonate, 48 x 96 mm Outputs relays: 2 change over contacts 230 VAC Analogue: 0/4-20... Created on 16/11/2009 17:26 and updated on 10/12/2019 13:20 |
222-03 Page |
SDD 911 Pressure relief valves - ND 10 to ND 25 Page (911-03) A pressure relief valve SDD 911 limits the static pressure to a maximal settled value by opening the outlet (to the discharge line) when the pressure is overriding. Pressure: Class PN 10 (at 20°C) Set up range: 0.5 to 10 bar Temperature limits PPH:... Created on 25/06/2010 15:45 and updated on 10/04/2018 14:37 |
911-03 Page |
CL4 Free chlorine sensor, at constant pH Starting Up Notice (193-02)
Created on 20/12/2010 11:04 and updated on 10/04/2018 15:25 |
193-02 Starting Up Notice |
VEP FE-PVC Electrically actuated butterfly valves Page (914-03) ND 65 to ND 200 In-line pattern Electric actuator, Position index Manual operating for immediate action • PVC Valve from ND 50 up to ND 200 • In-line pattern • Electric actuator; Position index; Manual operating for emergency Created on 08/12/2011 15:29 and updated on 18/12/2019 15:03 |
914-03 Page |
Disclaimer Page ()
Created on 29/03/2012 10:29 and updated on 29/03/2012 10:29 |
Page |
BMPC 4896 Wall mount cabinet for 48x96 mm indicators Page (222-05) • IP 55 Wall mount cabinet • Grey polycarbonate • Dimensions 159x149x151 mm • With 5 cable glands Created on 10/12/2019 13:26 and updated on 10/12/2019 13:31 |
222-05 Page |
BAMOSONIC Ultrasonic level transmitter for liquids Page (597-06) • Measuring range from 0.2 to 8 m (liquids) • Non-contact level measurement • Power supply by 4-20 mA Loop • IP67 Ingress protection • Option : Plug-in display Created on 11/12/2019 16:07 and updated on 11/12/2019 16:16 |
597-06 Page |
TP 805 Pressure transducer Page (805-04) • Compact and robust construction • Output signal: 4-20 mA; 2-wire • Pressure: 0 ... 2.5 barg up to 25 barg • AISI 316 Fitting: ½" G or ¼" G • Ceramic diaphragm Created on 18/12/2019 09:43 and updated on 18/12/2019 10:02 |
805-04 Page |
VENTURI CHANNEL DEBITFLO Flow rate measurement in open channel Page (755-01) Manufactured Venturi channels are dedicated for flow rate measurement in open flumes, and totalization on effluents Created on 09/10/2006 17:26 and updated on 10/04/2018 14:27 |
755-01 Page |
BF 1200 SERIES Conductivity measuring cell Page (361-01) • Cell factor K = 1 • Fitting PG 13.5 • Body: Glass tube Ø 12 mm • Platinum measuring elements Created on 18/05/2007 10:15 and updated on 10/12/2019 15:30 |
361-01 Page |
9054 pH Connector Accessories Starting Up Notice (160-01)
Created on 10/08/2007 10:47 and updated on 10/04/2018 15:19 |
160-01 Starting Up Notice |
Option: 4 stages regulation processor pH/mV Meter BAMOPHOX 106 Starting Up Notice (106-02)
Created on 25/11/2008 14:02 and updated on 10/04/2018 14:52 |
106-02 Starting Up Notice |
DIRECTIVE 2002/95/CE RoHS News () Dear Partners, We also are concerned with the environmental protection and the RoHS requirements 2002/95/CE. What is the objective? The directive RoHS shall limit the use of toxic and harmful materials in the manufacture of electric and electronic... Created on 21/12/2009 17:21 and updated on 21/12/2009 17:21 |
News |
RDP 906 Pressure reducing valves Starting Up Notice (906-02)
Created on 15/03/2011 11:17 and updated on 10/04/2018 16:00 |
906-02 Starting Up Notice |
VPP K4-PPH Pneumatically actuated butterfly valves, single / double acting Starting Up Notice (913-06)
Created on 12/12/2011 17:36 and updated on 10/04/2018 16:04 |
913-06 Starting Up Notice |
IFAT 2012 News () We shall be exhibiting our products in Munich at IFAT 2012, the world's leading trade fair for water, sewage, waste and raw materials management. 07 th to 11 th of May, 2012 - New Munich trade fair centre - Hall 5, booth 506. Besuchen Sie uns auf... Created on 04/04/2012 20:13 and updated on 10/04/2018 16:18 |
News |
BAMOPHAR 451 Dissolved oxygen monitor Page (451-03) • Dissolved oxygen measurement • Scales: 0.01 to 50 mg/l or 0 to 500 % • 1 Input for AQUAPLUS probe • 2 Analogue outputs 0/4-20mA • 4 Relay outputs (Thresholds and alarm) • OPTIONS: Extension terminal for 2nd measuring parameter Created on 10/12/2019 16:16 and updated on 10/12/2019 16:18 |
451-03 Page |
BV - BR Metallic flow controller & indicator Page (720-01) • Vertical mounting • 1 Indicator + 1 adjustable contact • Material: stainless steel or brass • Pressure limit 10 bar • Flow ranges within 0.1 ... 50 l/min Created on 17/12/2019 10:59 and updated on 17/12/2019 11:06 |
720-01 Page |
VM3V S4 Manually operated 3-way ball valves, industrial series Page (935-01) • Secure and lockable handle • Radial mounting and dismounting • 100% full flow Created on 18/12/2019 15:56 and updated on 18/12/2019 16:11 |
935-01 Page |
BAMOPHOX 450 Dissolved oxygen monitoring Starting Up Notice (450-02)
Created on 14/06/2007 11:35 and updated on 10/04/2018 15:33 |
450-02 Starting Up Notice |
TEMPERATURE PROBES WITH Pt 100 Ω SENSOR Page (610-02)
Created on 20/12/2007 14:02 and updated on 10/04/2018 14:23 |
610-02 Page |
NivOil® / 230 V AC Alarm system for oil-water separators Page (531-01) Designed for the monitoring of hydrocarbon fluids separators, the converter NivOil® may be connected to 1, 2, or 3 sensors. The 3 sensors may be connected to any input. Hydrocarbon fluid layer thickness sensor to detect when the maximum thickness... Created on 12/02/2009 13:51 and updated on 10/04/2018 14:02 |
531-01 Page |
NivOil® / 12 V dc Alarm system for oil-water separators Page (531-02) Low power consumption 10...27 V dc power supply input Zone 0 ATEX certified (Zone 2 for the alarm device location) Solar powered or standard electric battery Energy saving mode adjustable (control frequency adjustable from 6 min up to 9 days) 3... Created on 07/01/2010 18:07 and updated on 10/04/2018 14:03 |
531-02 Page |
PRESSURE GAUGES Starting Up Notice (812-04)
Created on 26/11/2010 16:59 and updated on 10/04/2018 15:58 |
812-04 Starting Up Notice |
BAMOPHOX 216 Data monitor – Data recorder Page (216-01) Alphanumeric back lighted LCD display Parameters and programming: Input sensor signal, scale Measuring range Displayed unit (m, cm, %, ppm, mg, g) Scale from 0.001 to 9999 Wall mounting IP 65 or panel mounting 3 relay outputs, 2 analogical outputs... Created on 18/11/2011 16:14 and updated on 10/04/2018 13:45 |
216-01 Page |
VE3V S4-PVC Electrically actuated 3-way ball valves Starting Up Notice (914-02)
Created on 28/03/2012 16:28 and updated on 10/04/2018 16:07 |
914-02 Starting Up Notice |
CL4.2 Free chlorine sensor, at constant pH Page (193-03) • Water treatment • pH must be constant • No tolerance to surfactants • Temperature 45 °C max. • Pressure 1 bar max. Created on 04/12/2019 14:40 and updated on 04/12/2019 14:53 |
193-03 Page |
GNR 6 Level indicator Page (572-01) • Direct reading on site • Measuring tube O.D. 63 mm • Wet parts: PVC and PPH • Stop valves, included • Options: Level switches, graduated ruler Created on 11/12/2019 13:58 and updated on 11/12/2019 14:01 |
572-01 Page |
DUM/A Flow controller with indicator, metallic Page (725-03) • Operates in all positions • Indicator, plus 1 adjustable contact • Versions: Stainless steel or brass • Pressure: up to 300 bar • Flow ranges: 0.2 ... 250 l/min Created on 17/12/2019 14:57 and updated on 17/12/2019 15:04 |
725-03 Page |
BAMO France BAMO Mesures () Fabricant français de capteurs et d'instruments pour contrôle et analyse des fluides Created on 30/03/2012 17:18 and updated on 30/03/2012 17:20 |
|
News Category () General Information/ Created on 23/09/2006 18:33 and updated on 27/03/2018 15:42 |
Category |
Workshops Head Office Page () Our Facilities BAMO Mesures SAS in Argenteuil: we opened our new building in July 11, 2005 West front, main entrance It is an efficient building for manufacturing, with Stores, Commercial and Development facilities. The Head office is able to afford a... Created on 01/04/2012 11:17 and updated on 10/04/2018 16:26 |
Page |
pH and ORP 100 Category (100) User Manuals/ Created on 28/09/2006 22:53 and updated on 03/04/2018 11:21 |
100 Category |
pH and ORP 100 Category (100) General Catalog/ Created on 23/09/2006 18:42 and updated on 03/04/2018 11:27 |
100 Category |
Chlorine, disinfection 190 Category (190) User Manuals/ Created on 12/10/2010 19:00 and updated on 03/04/2018 11:21 |
190 Category |
Chlorine, disinfection 190 Category (190) General Catalog/ Created on 12/10/2010 18:54 and updated on 03/04/2018 11:28 |
190 Category |
BAMO Deutschland BAMO IER () Innovative Messtechnik für Füllstand, Trübung und Analyse in Flüssigkeiten Created on 30/03/2012 17:22 and updated on 19/11/2013 16:07 |
|
About us Category () General Information/ Created on 23/09/2006 18:39 and updated on 27/03/2018 15:44 |
Category |
Data processors 200 Category (200) User Manuals/ Created on 28/09/2006 22:54 and updated on 03/04/2018 11:22 |
200 Category |
Data processors 200 Category (200) General Catalog/ Created on 23/09/2006 18:43 and updated on 03/04/2018 11:28 |
200 Category |
R&D For Your Safety Page () Product development is conducted in accordance with DIN EN ISO 9001:2000 procedures, as well as all applicable legal requirements and European standards. Testing in our own EMC lab, as well as by external approval authorities (i.e. TÜV, BIBt etc.),... Created on 10/10/2006 19:07 and updated on 10/04/2018 16:27 |
Page |
BAMO Portugal GLOBALÁGUA, LDA () Instrumentação e Controlo de Águas Created on 02/02/2016 10:12 and updated on 02/02/2016 10:13 |
|
Contact Us Category () You can contact us Via: E-mail: Phone: Fax: Post: Link to: General Information/ Created on 04/04/2012 20:35 and updated on 27/03/2018 15:49 |
Category |
Manufacturing and assembly Page () All of the necessary technologies are at our disposal - in house. This guarantees us the flexibility we need to produce custom devices for you in the shortest time. Well trained employees, as well as documented procedures and work directives wich have... Created on 10/10/2006 19:10 and updated on 10/04/2018 16:27 |
Page |
Conductivity 300 Category (300) User Manuals/ Created on 28/09/2006 22:54 and updated on 03/04/2018 11:22 |
300 Category |
BAMO International Category () General Information/ Created on 29/03/2012 09:42 and updated on 27/03/2018 15:50 |
Category |
Conductivity 300 Category (300) General Catalog/ Created on 23/09/2006 18:44 and updated on 03/04/2018 11:29 |
300 Category |
Water hardness 375 Category (375) General Catalog/ Created on 12/10/2010 18:57 and updated on 03/04/2018 11:29 |
375 Category |
Turbidity 400 Category (400) User Manuals/ Created on 06/11/2006 15:33 and updated on 03/04/2018 11:23 |
400 Category |
BAMO Polska BAMO Polska Sp. z o.o. () Europejski producent czujników oraz urządzeń do kontroli i analizy cieczy Created on 10/09/2014 14:59 and updated on 24/09/2019 14:46 |
|
Testing Page () All electrical devices are subjected to strict, individual testing. Adherence to documented inspection procedures assures flawless functioning of all subassemblies and components during production, as well as after final assembly. Additional testing... Created on 10/10/2006 19:12 and updated on 10/04/2018 16:30 |
Page |
BAMO España GlobalAgua España () Fabricante europeo de sensores e instrumentos para líquidos Created on 30/03/2012 17:29 and updated on 24/10/2013 11:30 |
|
Turbidity 400 Category (400) General Catalog/ Created on 11/10/2006 17:33 and updated on 03/04/2018 11:29 |
400 Category |
Oxygen 450 Category (450) User Manuals/ Created on 28/09/2006 22:55 and updated on 03/04/2018 11:23 |
450 Category |
Oxygen 450 Category (450) General Catalog/ Created on 23/09/2006 18:46 and updated on 03/04/2018 11:30 |
450 Category |
Level 500 Category (500) General Catalog/ Created on 23/09/2006 18:46 and updated on 03/04/2018 11:31 |
500 Category |
BAMO International BAMO Mesures () European manufacturer of sensors and instruments for liquids Created on 30/03/2012 17:25 and updated on 30/03/2012 17:26 |
|
Company History Page () BAMO MESURES SAS has been founded in 1978. Its capital is now 400 000 Euros. Since the beginning, the company has undergone a rapid development centring on industrial pH-meters and conductivity meters. BAMO is now well-known as a leader on the French... Created on 01/04/2012 11:08 and updated on 01/04/2012 11:31 |
Page |
Level 500 Category (500) User Manuals/ Created on 28/09/2006 22:55 and updated on 03/04/2018 11:24 |
500 Category |
Temperature 600 Category (600) General Catalog/ Created on 23/09/2006 18:47 and updated on 03/04/2018 11:31 |
600 Category |
Terms and Conditions of Sales Foreign Countries Page () Terms and conditions Unless otherwise stipulated in our offer or documentation, the terms and conditions of sale hereinafter apply to all services and products we commercialize. Created on 27/06/2011 17:18 and updated on 01/04/2012 11:35 |
Page |
Flow 700 Category (700) General Catalog/ Created on 23/09/2006 18:47 and updated on 03/04/2018 11:32 |
700 Category |
Flow 700 Category (700) User Manuals/ Created on 28/09/2006 22:56 and updated on 03/04/2018 11:24 |
700 Category |
Pressure 800 Category (800) User Manuals/ Created on 15/09/2009 18:56 and updated on 03/04/2018 11:25 |
800 Category |
Pressure 800 Category (800) General Catalog/ Created on 15/09/2009 18:58 and updated on 03/04/2018 11:32 |
800 Category |
Plastic Valves 900 Category (900) User Manuals/ Created on 12/10/2010 19:11 and updated on 03/04/2018 11:25 |
900 Category |
Plastic Valves 900 Category (900) General Catalog/ Created on 23/09/2006 18:48 and updated on 03/04/2018 11:32 |
900 Category |
pH and ORP Category (100) Archives/ Created on 18/12/2019 17:22 and updated on 18/12/2019 17:23 |
100 Category |
Chlorine, Disinfection Category (190) Archives/ Created on 17/12/2019 17:02 and updated on 17/12/2019 17:03 |
190 Category |
Data processors 200 Category (200) Archives/ Created on 01/04/2012 15:07 and updated on 03/04/2018 11:26 |
200 Category |
Water hardness 375 Category () Archives/ Created on 04/02/2022 12:12 and updated on 04/02/2022 12:13 |
Category |
Turbidity Category () Archives/ Created on 04/02/2022 12:16 and updated on 04/02/2022 12:16 |
Category |
Oxygen Category () Archives/ Created on 04/02/2022 12:21 and updated on 04/02/2022 12:21 |
Category |
Level 500 Category (500) Archives/ Created on 01/04/2012 15:14 and updated on 03/04/2018 11:26 |
500 Category |
NIVOSTOP® - SS2 / HYP Level controller, all in Hypalon Page (520-02) Compatibility with basic, leak acid solutions and other aggressive chemicals Restrictions: due to the cable made of HYPALON and additives Adjustable ballast Maximal pressure 5.5 bar Maximal temperature 95°C Created on 26/11/2009 12:44 and updated on 10/04/2018 16:32 |
520-02 Page |
Flow 700 Category (700) Archives/ Created on 01/04/2012 15:15 and updated on 03/04/2018 11:27 |
700 Category |
9500 In-line electrode holders under pressure Page (142-01) • pH or ORP measurement • Construction: AISI 316 L • Pressure max. 16 bar • Temperature max. 110 °C • Fittings PG13.5 or BSP 1/2'' • For electrodes with fitting PG 13.5 • Process connections ND 15 to 32 mm Created on 08/02/2007 16:03 and updated on 04/12/2019 11:46 |
142-01 Page |
BAMOPHOX 192 Free Chlorine monitoring with Open cell amperometric method Page (192-02) Alphanumeric back lighted LCD display Friendly using menu Ranges from 0 to 5 mg/l for free chlorine -20...+160°C for temperature 2 analogical outputs 0/4-20mA, galvanic insulated 3 relay outputs (Normally Open contacts) 1 relay output for system... Created on 03/01/2007 11:10 and updated on 10/04/2018 13:38 |
192-02 Page |
GA 1 – GA 2 – GA 11 – GA 5 Armatures for turbidity control Page (421-01) Sensor fixture with emitter and receiver To use with the turbidity controller TRUBOMAT GS3 DN 15 to DN 200 In-line mounting or as a by-pass Construction PVC, PPH, Stainless steel Sensor fixture with emitter and receiver To use with the turbidity... Created on 21/02/2007 17:24 and updated on 10/04/2018 13:55 |
421-01 Page |
MUDLine® TGS Portable sludge level measuring instrument Page (426-01) Battery powered Mud level detection in primary and secondary clarifier, thickener and other applications Useful also in rotten black sludge Sludge level monitoring in small sewage plants Immersion depth: 10 m as a maximum Field portable device Sludge... Created on 03/11/2006 11:22 and updated on 10/04/2018 13:56 |
426-01 Page |
MUDLine® TGS Portable sludge level measuring instrument Starting Up Notice (426-01)
Created on 03/11/2006 11:28 and updated on 10/04/2018 15:31 |
426-01 Starting Up Notice |
BAMOPHOX 106 pH-Meter and mV-Meter Starting Up Notice (106-01)
Created on 16/02/2007 10:37 and updated on 10/04/2018 14:50 |
106-01 Starting Up Notice |
9090 Temperature compensation probe Page (150-02) • For mounting on holders 9200, 9500 et 9346 • Sensor Pt 100 Ω at 0 °C • Versions: Simplex or Duplex • Fitting PG 13.5 Created on 26/02/2007 10:23 and updated on 04/12/2019 12:18 |
150-02 Page |
pH and ORP ACCESSORIES Accessories Page (160-01)
Created on 26/02/2007 11:32 and updated on 04/12/2019 13:57 |
160-01 Page |
BAMOTOP 281 Frequency converter Page (281-01) • For any pulse emitter such as: BAMOFLU, BAMOTUR, Micro-stream, FFG, DF 140, Counters M, BAMOMATIC (12 V) • Input modes to configure • Range: 1 ... 25000 Hz • Galvanic insulated output • Current: 0/4-20 mA or 0-5/10 V • Response time to set... Created on 16/05/2007 10:16 and updated on 10/12/2019 14:22 |
281-01 Page |
BAMOPHOX 319 ML-DB Resistivity Metre Page (319-02) 2 independent sensors Input 1: range 0...20 MΩ Input 2: scalable range 0...20 MΩ / 0...2 MΩ Dedicated probes and sensors With Factor probe C = 0.01, 0.1, 1 and 10 2 adjustable analog output 0/4-20 mA 3 relay outputs (NO contact) Wall mounting IP 65 Created on 28/02/2007 09:33 and updated on 10/04/2018 13:51 |
319-02 Page |
BAMOPHOX 322 Resistivity / Conductivity Page (322-01) Monitor and controller MΩ - mS Programmable scales: 0...200 Ω up to 0...20 MΩ 0...2 μS up to 0...20 mS TOR version, 0...2 mS up to 0...2000 mS Convenient probes: With cell contant, 10 ; 1 ; 0.1 ; 0.01 or with TOR sensor Automatic or manual... Created on 09/10/2006 11:09 and updated on 10/04/2018 13:52 |
322-01 Page |
TCS 3020 Series Inductive conductivity probe in NORYL Page (364-01) Process measurement on line or by immersion For waste liquids Wide range of applications Large scales: from 0-2 to 0-2000 mS Probe material: NORYL • Range: from 10 μS/cm up to 2000 mS/cm • Material: NORYL • Temperature max. 105 °C • Low... Created on 28/02/2007 10:35 and updated on 10/12/2019 15:36 |
364-01 Page |
TRUBOMAT GS 3 Turbidity controller Page (410-01) ON/OFF turbidity Controller No effect of day light Output relay Adjustable delay Dysfunction indicator Created on 22/02/2007 18:05 and updated on 04/02/2022 12:17 |
410-01 Page |
BAMOPHOX 436 Turbidity monitor Page (436-01) Alphanumeric back lighted LCD display 2 models available: Panel mounting 72 x 144 (436E) Wall mounting IP 65 (436M) 3 relay outputs (Normally Open contacts) 1 relay output for system alarm 2 analogical outputs 0/4-20mA Scales NTU, FAU, mg/L, g/L, FNU ... Created on 15/02/2007 11:26 and updated on 04/02/2022 12:18 |
436-01 Page |
TURBICUBE In line turbidity transmitter Page (444-01) Drinking water plants Raw and waste water Phase separation, filtration Measuring range: 0.01...1000 FNU Output signal: 0/4-20 mA Immediate connection to BAMOPHOX monitor, data logger and regulator Flow-through in-line turbidimeter acc. ISO 7027... Created on 15/02/2007 11:05 and updated on 10/04/2018 13:57 |
444-01 Page |
MNR 7 Magnetic float level controller Page (550-01) Available in PVC – PPH - PVDF Up to 4 bi-stable change over contacts High switch power capacity Independent from density. Foam or vapors do not interfere Option for a continuous measurement Specific documentation: 586 = RTM/MNR7 Available in PVC –... Created on 26/02/2007 11:15 and updated on 10/04/2018 14:09 |
550-01 Page |
MNR 7 - 316L Stainless steel magnetic float level controller Page (550-02) Construction: stainless steel 316 Up to 4 bi-stable change over contacts High switch power capacity Independent from density. Foam or vapors do not interfere Option for a continuous measurement, see our specific documentation 586 about RTM/MNR7 Created on 26/02/2007 10:58 and updated on 10/04/2018 14:09 |
550-02 Page |
MNR 7 Ex Magnetic float level controller Page (550-03) Construction: stainless steel 1.4571 (316 Ti – AISI) Up to 4 bi-stable change over contacts ATEX II 1/2 G - EEx ib IIC T4 Construction: stainless steel 1.4571 (316 Ti – AISI) Up to 4 bi-stable change over contacts ATEX II 1/2 G - EEx ib IIC T4 Created on 26/02/2007 10:47 and updated on 10/04/2018 14:10 |
550-03 Page |
MAXIMAT LW CN-SDR Leakage detection transmitter Page (555-04) Capacitive, high frequency, fail-safe detection For aggressive and conductive liquids Two sensors Positive active alarm Auto diagnostic system and LED indicator WHG §19, approval DIBt-No.: Z-65.40-316 Created on 13/02/2007 15:13 and updated on 10/04/2018 14:11 |
555-04 Page |
MAXIMAT LWC-B Leakage detection sensor Page (555-05) Floor standing leakage detector Capacitive, high frequency, fail-safe detection For aggressive and electrically conductive liquids Positive active alarm Auto diagnostic system and LED indicator Created on 13/02/2007 15:47 and updated on 10/04/2018 14:12 |
555-05 Page |
MAXIMAT SHR CS Measuring transducer Page (555-06) Alarm signal relay for leakage or overfill transmitters Designed for overfill and leakage sensors MAXIMAT®C, MAXIMAT®VK.., MAXIMAT®LW.., CAPSYTRON SFL DIBT Approval Designed for overfill and leakage sensors MAXIMAT®C, ... Created on 13/02/2007 16:05 and updated on 10/04/2018 14:12 |
555-06 Page |
MAXIMAT TC4 Signaling device 4 sensor inputs Page (555-07) 4 surveying channels for leakage or overfill transmitters 4 surveying channels For compact overfill or leakage sensors MAXIMAT® C, MAXIMAT® VK..., MAXIMAT® LW... Microprocessor controlled Automatic sensor detection and survey Sensors and... Created on 26/02/2007 11:22 and updated on 10/04/2018 14:12 |
555-07 Page |
MAXIMAT LW VK Leakage detection sensor Page (555-08) Float level fail-safe detection For aggressive and non electrically conductive liquids Positive active alarm Auto diagnostic system and LED indication when in use with a SHR C transducer Approvals: DIBT Z-65.40-272, for leakage detection,... Created on 13/02/2007 17:48 and updated on 10/04/2018 14:13 |
555-08 Page |
CST / KRC Relays for maximat and capsytron Page (555-09) Relays for compact overfill sensors MAXIMAT C.., leakage sensors , MAXIMAT LW-C... and CAPSYTRON… level switches, pumps protection Created on 26/02/2007 09:58 and updated on 10/04/2018 14:13 |
555-09 Page |
BRK 60 - BRT 60 Magnetic level contacts Page (585-02) Switching power of 60 VA Bistable switch, NC either NO, 3 wires IP 55 Housing in ABS For tubes of diameter 32, 40 and 63 mm High temperature version up to 200°C • Switching power: 60 VA • Bi-stable, change-over contact • IP 55 casing, in ABS •... Created on 27/03/2007 14:12 and updated on 11/12/2019 15:37 |
585-02 Page |
SFA Cable and pulleys level indicator Page (583-01) Easy to install Convenient to viscous, aggressive and waste liquids High, long or small tanks Adjustable level switches Kits for ordering • Easy to install • Convenient to viscous, aggressive, waste liquids • Up to 6 m high tanks • Adjustable... Created on 14/03/2007 17:13 and updated on 11/12/2019 14:40 |
583-01 Page |
SFA/E Cable and pulleys , gastight level indicator Page (583-02) Gas tight cable operated level indicator Vapours confining Fluid protection from contamination Convenient to viscous, aggressive, wasted liquids Adjustable on site, easy to install Even for high tanks • For storage tanks • Gastight indicator •... Created on 15/03/2007 18:17 and updated on 11/12/2019 14:43 |
583-02 Page |
SFA series Parts Page (583-03) Unit: %, height, Volume, Mass/Weight Any ruler with a length over 4.6 m is delivered in 2 parts. (the fitting for assemble is included) . A drawing for acceptance is submitted before we manufacture the ruler. A complete set for your level... Created on 15/03/2007 18:25 and updated on 11/12/2019 14:50 |
583-03 Page |
SFA / CR Level indicator, reduced path Page (583-04) • Convenient to a wide range of liquids • Easy to install; Simple to use • Reduced graduated ruler • Guided float • Adjustable level switches Created on 15/03/2007 18:34 and updated on 11/12/2019 14:52 |
583-04 Page |
FLOATS – COUNTERWEIGHTS Actuators for level switches Page (585-03)
Created on 28/03/2007 08:53 and updated on 11/12/2019 15:49 |
585-03 Page |
BAMOPHOX 759 Venturi channel flow calculator Page (759-02) Programmable for level, instantaneous flow, daily volume, permanent cumulated volume Also within memorized curves for VENTURI, V or U overflow weir Input signal: 0/4-20 mA Output signal: 0/4-20 mA 4 adjustable limit relays Wall mounting housing IP... Created on 22/03/2007 18:01 and updated on 10/04/2018 14:28 |
759-02 Page |
BAMOFLU 100 Flowsensor Page (780-01) The flowing fluid maintains in rotation the five blades rotor and each blade has a built-in magnet, not in contact with the fluid Created on 09/10/2006 16:01 and updated on 10/04/2018 14:34 |
780-01 Page |
100/150 P 600 Bourdon tube pressure gauge “all stainless steel” acc. EN 837.1 Page (812-05) CASE DIAMETER 100 or 150 mm ACCURACY Class 1 SCALE RANGES From 0...0.6 bar to 0...1600 bar PRESSURE LIMITS DURING OPERATION Continuously: steady pressure up to F.S. value Fluctuating pressure: 90% of F.S. value Temporarily: 1.3 x F.S. value for... Created on 15/06/2010 15:32 and updated on 10/04/2018 14:35 |
812-05 Page |
DP800 Differential pressure gauge Page (812-14) Case diameter: 100 or 150 mm Accuracy: Class 1.6 Scale ranges: From 0...60 mbar to 600 mbar...25 bar Overpressure: 100 bar on one input at a time Static pressure limit: 200 bar as a maximum, all scales Temperature limits Ambient: -25 to +65°C Process:... Created on 09/09/2010 11:40 and updated on 10/04/2018 14:35 |
812-14 Page |
SWITCHES FOR GAUGES Page (812-17)
Created on 23/06/2010 10:58 and updated on 10/04/2018 14:36 |
812-17 Page |