Preview There are 150 results for Relevancy
EVERETS 214
2 channels measuring amplifier for 0/4-20 mA sensors 1E Starting Up Notice (232-03)

Created on 28/06/2007 15:54 and updated on 10/04/2018 15:20

232-03

1E

Starting Up Notice
GNR 5 / PVC
Level indicator controller 1E Starting Up Notice (571-01)

Created on 26/06/2008 15:14 and updated on 10/04/2018 15:46

571-01

1E

Starting Up Notice
MEMPRO S6
Hydrostatic level controller 1E Page (592-03)

Convenient for level controls on non-pressurised tank 4 switching points, adjustable over all the measuring range Convenient for aggressive and loaded fluids even viscous or / and sticky fluids Range: up to 10 m Water Column Reliable, without mobile...

Created on 19/11/2009 16:36 and updated on 10/04/2018 14:22

592-03

1E

Page
CS2.3
Free chlorine sensor, without effect from pH changes 1E Starting Up Notice (193-04)

Created on 22/12/2010 14:03 and updated on 10/04/2018 15:25

193-04

1E

Starting Up Notice
VE2V S4-PPH
Electrically actuated 2-way ball valves 1E Page (914-04)

ND 10 to ND 100 In-line pattern Electric actuator, Position index Manual operating for immediate action

Created on 08/12/2011 15:38 and updated on 10/04/2018 14:43

914-04

1E

Page
BXNT
Intrinsic safety converter 1E Page (235-01)

• Approval IIC ATEX II (1) G/D • Main power 230 V AC • Input and output: 4-20 mA • DIN rail mounting

Created on 10/12/2019 13:33 and updated on 10/12/2019 13:40

235-01

1E

Page
EasyTREK
Ultrasonic level transmitter 1E Page (598-01)

• Height range 0.15 to 18 m, for liquids • Non-contact level measurement • HART® 7 protocole • Output signal 4-20 mA • IP 68 (allows accidental immersion)

Created on 11/12/2019 16:17 and updated on 11/12/2019 16:29

598-01

1E

Page
A32
Needle valve 1E Page (816-01)

• Made from metal bar stock • Operating pressure: 413 bar Max. • Temperature: 240 °C Max.

Created on 18/12/2019 10:04 and updated on 18/12/2019 10:11

816-01

1E

Page
BAMOBUL
Air bubbling level transmitter 1E Page (758-02)

BAMOBUL is designed for Venturi channel or Weir plates (documentation 755-01) water level measurements up to 500 mm

Created on 09/10/2006 17:43 and updated on 10/04/2018 14:28

758-02

1E

Page
BIR 7110
Panel mounting indicator 1E Page (221-02)

Inputs: Thermocouples, Pt 100 Ohm  Easy configuration  Display 5 digits  Housing 48 x 96 mm  Front IP65  Main power 95…265 V AC  Min. / Max. memory  Programmable ramp: 9 segments  Options:  Output for signal as a 4-20 mA  Supplementary relay...

Created on 18/05/2007 10:49 and updated on 10/04/2018 16:31

221-02

1E

Page
DEBITFLO
Flow rate measurement in open channel 1E Starting Up Notice (755-01)

Created on 29/08/2007 10:57 and updated on 10/04/2018 15:53

755-01

1E

Starting Up Notice
MNR 7
Magnetic float level controller 1E Starting Up Notice (550-01)

Created on 18/12/2008 10:18 and updated on 10/04/2018 15:41

550-01

1E

Starting Up Notice
New terminal heads for BAMO
1E News ()

This year 2006, are appearing new perspectives for BAMO and part of them are some red head housings, the most visible changes. They will fit at least all our field instrumentation: flow, turbidity, ph, conductivity probes and more... Thanks to these red...

Created on 21/12/2009 17:23 and updated on 10/04/2018 16:24



1E

News
SDD 912
Pressure relief valves - ND 32 to ND 50 1E Page (912-02)

Pressure relief valves SDD 912 limits the static pressure to a maximal settled value by opening the outlet (to the discharge line) when the pressure is overriding. All wetted parts in plastic Protection of pumps and process lines Affordable cost...

Created on 20/05/2011 10:46 and updated on 10/04/2018 14:37

912-02

1E

Page
VP2V S4-PVDF
Pneumatically actuated 2-way ball valves, single / double acting 1E Starting Up Notice (913-07)

Created on 12/12/2011 17:39 and updated on 10/04/2018 16:04

913-07

1E

Starting Up Notice
NIVASWITCH
Vibrating fork level detector 1E Page (513-03)

• Detection of level for liquids • Continuous monitoring • Operating even with turbulences • Unnecessary calibration routine • Operating even with suspended solids

Created on 11/12/2019 10:27 and updated on 11/12/2019 10:32

513-03

1E

Page
BR
Metallic flow controllers 1E Page (720-02)

• Vertical mounting • 1 adjustable contact • Material: stainless steel or brass • Pressure limit: up to 300 bar • Flow ranges within 0.1 ... 50 l/min

Created on 17/12/2019 11:07 and updated on 17/12/2019 11:15

720-02

1E

Page
VM2V CR
Manually operated 2-way ball valves, water series 1E Page (938-03)

• Radial mounting and dismounting • 100% full flow • Maintenance free

Created on 18/12/2019 16:13 and updated on 18/12/2019 16:20

938-03

1E

Page
BAMOPHOX 106
pH-Meter and mV-Meter 1E Page (106-01)

The BAMOPHOX 106 offers high flexibility on use mixing different built-in programmes for regulation, thresholds, temperature compensation, and alarms

Created on 02/10/2006 12:11 and updated on 18/12/2019 17:23

106-01

1E

Page
9400
On-line holder for pH or ORP electrode 1E Page (141-01)

• On-line holders for 1 electrode • For full piping • Materials: PPH or PVDF • Mounting: screw fitting 3/4" G • Version for inserting and removing the electrode (PG 13.5) with full pipe

Created on 15/06/2007 14:35 and updated on 04/12/2019 11:34

141-01

1E

Page
TS 12
Temperature probe with Pt 100 Ω sensor 1E Page (612-01)

- Sensor: Pt 100 Ω at 0 °C - Range from -50 °C up to +250 °C - Stem in AISI 316 L - Water-tight cable output

Created on 20/12/2007 14:20 and updated on 11/12/2019 16:42

612-01

1E

Page
JAR
Level gauge 1E Page (582-01)

Stainless steel Cat & Mouse Level indicator with metallic parts Wide scale Graduated in %, m3, L Long height possible Protected pulleys with a no jump system Sections of 1500 mm, adjustable total length • Metallic level indicator • Height up...

Created on 12/02/2009 14:25 and updated on 11/12/2019 14:17

582-01

1E

Page
BAMOBOX SOLAR (BBS)
Solar powered alarm unit for oil-water separators 1E Page (531-03)

A complete system BBS will power an alarm unit NivOil® 10...27 V DC when no main power supply exists in the field. Autonomous complete system Field installation Solar panel powered and battery Pole clamp fitting or wall mounting Battery protection...

Created on 11/02/2010 15:47 and updated on 11/12/2019 12:56

531-03

1E

Page
SDD 911
Pressure relief valves - ND 10 to ND 25 1E Starting Up Notice (911-03)

Created on 26/11/2010 17:06 and updated on 10/04/2018 16:00

911-03

1E

Starting Up Notice
BAMOPHOX 451
Dissolved oxygen monitor 1E Page (451-02)

Display and control Logger included Recording on memory card (up to 150 000 records) Phoxlog software included Alphanumeric back lighted LCD display Friendly using menu Data-logger on MMC card 1 input for sensor AQUAPLUS Scales: 0 to 500% or in mg/L 2...

Created on 25/11/2011 17:48 and updated on 04/02/2022 12:22

451-02

1E

Page
VEP K4-PVC
Electrically actuated butterfly valves 1E Starting Up Notice (914-03)

Created on 28/03/2012 16:38 and updated on 10/04/2018 16:07

914-03

1E

Starting Up Notice
CS4
Free chlorine sensor 1E Page (193-07)

- Treatments of Fresh water and sea-water - Surfactants: partial tolerance - Low incidence of pH changes - Temperature: 45 °C max. - Pressure: 3 bar max.

Created on 04/12/2019 15:32 and updated on 04/12/2019 15:45

193-07

1E

Page
GNR 5 / INOX
Level indicator - Controller 1E Page (575-01)

• Direct reading • Construction: AISI 316 L and glass • C to C: Up to 2000 mm

Created on 11/12/2019 14:02 and updated on 11/12/2019 14:05

575-01

1E

Page
IDP / PDP
Fittings - Flanges - Seals 1E Page (730-04)

Created on 17/12/2019 15:05 and updated on 17/12/2019 15:22

730-04

1E

Page
BIR 9000
Panel mounting indicator 1E Page (222-02)

Inputs: 4-20 mA, 0-10 mA, 0-10 V, 1-5 V  Easy configuration  Display 5 digits  Housing 48 x 96 mm  Front IP65  Main power 95…265 V AC  Integrated sensor supply Min. / Max. values in memory  Programmable ramp: 9 segments

Created on 29/06/2007 11:54 and updated on 10/04/2018 16:31

222-02

1E

Page
BIR 4000
Panel mounting indicator 1E Page (220-01)

Analogic signal input, mA or V, DC Display 3 1⁄2 digits, red LED 14 mm height Small sized housing, 48x96x60 mm Front protection IP65 Removable screw connectors Main power supply 115 to 230 V – 50/60 Hz Power supply to sensor 24 V DC Optional 2 alarm...

Created on 30/06/2008 13:44 and updated on 10/04/2018 16:30

220-01

1E

Page
MEMPRO S6
Hydrostatic level controller 1E Starting Up Notice (592-03)

Created on 19/11/2009 16:47 and updated on 10/04/2018 15:51

592-03

1E

Starting Up Notice
AMPEROMETRIC SENSORS
1E Page (193-01)

• Free chlorine • Total chlorine • Chlorine dioxide • Hydrogen peroxide • Peracetic acid - Wide measuring ranges - Limits up to 70 °C and 8 bar - Unnecessary zero adjustment - Reliable measuring signal - Built-in temperature compensation...

Created on 27/09/2010 16:07 and updated on 04/12/2019 14:38

193-01

1E

Page
CP 2.1
Total chlorine sensor, measuring free from pH changes 1E Starting Up Notice (193-05)

Created on 27/12/2010 15:15 and updated on 10/04/2018 15:25

193-05

1E

Starting Up Notice
VE3V S4-PPH
Electrically actuated 3-way ball valves 1E Page (914-05)

ND 10 to ND 50 In-line pattern Electric actuator, Position index Manual operating for immediate action

Created on 08/12/2011 15:47 and updated on 10/04/2018 14:43

914-05

1E

Page
GsM 25e
Modem GSM / GPRS 1E Page (248-02)

• Remote information report • 2G enclosure for supervision and alarm • 3 Inputs / 1 Output • Set up software included

Created on 10/12/2019 13:45 and updated on 10/12/2019 13:50

248-02

1E

Page
MUDSENS
Sludge level probe 1E Page (599-02)

• Ultrasonic probe • Level monitoring of sludge in sedimentation tanks • Advanced algorithm • Output 4-20 mA: representative of sludge level • Cleaning with compressed air • User-friendly menu

Created on 11/12/2019 16:31 and updated on 11/12/2019 16:34

599-02

1E

Page
V182 – V82
Pressure reducing valves 1E Page (906-03)

• Body : PVC, PP or PVDF • Diaphragm: in EPDM with PTFE coat • V182: Spigot ends from ND 10 up to ND 50 • V 82 : Spigot ends from ND 65 up to ND 100 • Gauge 0-10 bar, with built-in gauge guard

Created on 18/12/2019 10:24 and updated on 18/12/2019 10:31

906-03

1E

Page
BIR 8004 SERIE
Numerical Indicator 4 Normaly Open Contacts 1E Page (222-01)

Imput 4 - 20 mA 4 setting NO contacts Supply 230 V - 50/60 Hz Simplified setting Display +/- 2000 pts Display 3 1/2 digits LCD 12,5 mm Pannel mounting IP 55 Removable wiring connectors Sensor supply 230 V Output NO relays contacts Adjustable hyteresis...

Created on 09/10/2006 18:01 and updated on 10/04/2018 16:31

222-01

1E

Page
BAMOPHOX 436
Turbidity monitor 1E Starting Up Notice (436-02)

Created on 23/05/2007 18:04 and updated on 10/04/2018 15:31

436-02

1E

Starting Up Notice
BCP 48
Programmable counter 1E Page (289-01)

Universal and simple Double back-lighted LCD display Main counter 8 digits Totalizer Second counter 6 digits Batch counter with two pre-setting 4 programming mode Supply sensor 24 V DIN 48 x 48 enclosure box

Created on 06/09/2007 09:29 and updated on 10/04/2018 13:49

289-01

1E

Page
MNR 7 Stainless steel
Stainless steel magnetic float level controller 1E Starting Up Notice (550-02)

Created on 19/12/2008 17:12 and updated on 10/04/2018 15:41

550-02

1E

Starting Up Notice
MUDLINE
Sludge level controller 1E News ()

Perfect control of sludge level in sedimentation basin. Easy, quick and accurate measurement New answers for operators of WWTP to their needs of reliable information on sludge levels. The MUDLINE is an innovation on these applications: - Autonomous -...

Created on 21/12/2009 17:28 and updated on 10/04/2018 16:23



1E

News
VP3V S4-PVDF
Pneumatically actuated 3-way ball valves, single / double acting 1E Starting Up Notice (913-08)

Created on 12/12/2011 17:41 and updated on 10/04/2018 16:05

913-08

1E

Starting Up Notice
NIVOSTOP® / C
Float level detector 1E Page (520-04)

• For aggressive liquids • Cable in FEP, seal in FPM, body in PP • Temperature max. 100 °C • Built-in counterweight • Standard cable lengths: 5, 10 & 20 m

Created on 11/12/2019 10:41 and updated on 11/12/2019 10:48

520-04

1E

Page
SIG 4.0
Analogue transmitter for flow controllers 1E Page (720-10)

• For flow controllers • Output: 4 ... 20 mA or 0 ... 10 V • Accuracy: ±10 % FS • Already set in factory

Created on 17/12/2019 11:17 and updated on 17/12/2019 11:23

720-10

1E

Page
BV 91 - BV 95
Vent valves 1E Page (949-02)

• Air inlet and outlet controls • Body: PVC, PP or PVDF • From ND 10 up to ND 80 • BV 91 free ball valve, for tank ventilation • BV 95 ball valve, spring assistance, for tank ventilation & vacuum breaking

Created on 18/12/2019 16:21 and updated on 18/12/2019 16:25

949-02

1E

Page
9200
In-line holders for 1 to 3 electrodes, pH or ORP 1E Page (140-01)

pH or ORP continuous flow cells For 1 to 3 electrodes pH, mV PVC or PPH material Various process connections available • Holder for 1, 2 or 3 electrodes • Construction: PVC or PPH • Process fitting: Union ND 20, diam. 25 mm

Created on 05/10/2006 17:31 and updated on 04/12/2019 11:17

140-01

1E

Page
9423
In-line probe electrode holder 1E Starting Up Notice (141-01)

Created on 15/06/2007 17:26 and updated on 10/04/2018 15:18

141-01

1E

Starting Up Notice
TS 16
Temperature sensor 1E Page (616-01)

Pt 100 Ω at 0 °C Measurement range -200 ...+600 °C Stainless steel stem Waterproof cable output

Created on 20/12/2007 14:29 and updated on 10/04/2018 14:25

616-01

1E

Page
MAXITOP
Compact overfill sensor 1E Page (556-01)

Universal use for electrically conductive, non-flammable water endangering liquids According  WHG § 19  in Germany,  the series is called MAXIMAT® C. No moving parts Process connection BSP 2", PVC, sliding Stem PEHD: Ø 40 mm Adjustable immersion...

Created on 25/03/2009 14:56 and updated on 10/04/2018 14:15

556-01

1E

Page
MAXITOP LWC
Leakage detection probe 1E Page (556-03)

Leakage sensor Universal use for electrically conductive, non-flammable water endangering liquids According  WHG § 19  in Germany,  the series is called MAXIMAT® LW-C. Stem: PEHD, Ø 40 mm  (Ø 25 on request) With fastening angle and adjustable...

Created on 10/03/2010 15:12 and updated on 10/04/2018 14:15

556-03

1E

Page
Pooltest 3
Photometer for chlorine and isocyanuric acid 1E Page (190-10)

• For swimming pools • Measuring ranges Chlorine from 0.01 to 5 & 10 mg/l Isocyanuric acid from 2 to 200 mg/l pH from 6.5 to 8.4 • Delivered ready to use

Created on 06/12/2010 15:06 and updated on 04/12/2019 14:19

190-10

1E

Page
VP3V S4-PVC
Pneumatic 3-way ball valves single or double acting 1E Page (913-02)

ND 10 to ND 50 In-line pattern Pneumatic actuator Single or double acting Position index Status NC or NO • PVC Valves from ND 10 up to ND 50 • Pneumatic actuator Single or double acting • Position pointer • Options: Limit switches box Pilot...

Created on 07/12/2011 11:38 and updated on 18/12/2019 11:21

913-02

1E

Page
VE2V S4-PPH
Electrically actuated 2-way ball valves 1E Starting Up Notice (914-04)

Created on 28/03/2012 16:42 and updated on 10/04/2018 16:08

914-04

1E

Starting Up Notice
OZ7
Ozone sensor 1E Page (193-21)

- Drinkable water, sea water - Surfactants: partial tolerance - Temperature: 45 °C max. - Pressure: 1 bar max.

Created on 04/12/2019 16:33 and updated on 04/12/2019 16:44

193-21

1E

Page
JEPA 580
Level gauge Electro-pneumatic, autonomous 1E Page (580-02)

• For compatible liquids (diesel, water, ...) • Displays in cm or Volume • For any kind of tanks • Battery operated • Height max.: Diesel 3 m; Water 2.5 m

Created on 11/12/2019 14:06 and updated on 11/12/2019 14:08

580-02

1E

Page
IDP
Plastic flow indicator 1E Page (730-05)

• Direct reading • All wet parts in plastics • Measuring tubes: PVC or Polysulfone • Ranges: Up to 60 m³/h Specific scales for Air, HCl, NaOH, etc. • Options: Adjustable contacts, ruler with 4-20 mA transmitter

Created on 17/12/2019 15:24 and updated on 17/12/2019 15:35

730-05

1E

Page
RTM
Continuous level transmitter 1E Page (586-01)

Signal output: 4-20 mA Step: 10 mm The RTM is adapted to our level indicators MAGTOP, SFA, MNR 6 and MNR 7. Continuous level transmitter Output 4-20 mA or Ohm Accuracy: 10 mm Direct mounting above the tank Available for MAGTOP and SFA

Created on 27/03/2007 14:20 and updated on 10/04/2018 14:20

586-01

1E

Page
TRUBOMAT GS3
Turbidity controller 1E Starting Up Notice (410-01)

Created on 30/07/2007 16:51 and updated on 10/04/2018 15:31

410-01

1E

Starting Up Notice
RXM 2851
Resistive amplifier relay 1E Page (533-01)

For highly resistive medium Input adjustable from 4.7 to 100 MΩ Adjustable sensitivity from the front Selectable mode function Function: ON/OFF detection between 2 electrodes

Created on 04/08/2008 09:34 and updated on 10/04/2018 14:04

533-01

1E

Page
CS2.3
Free chlorine sensor, without effect from pH changes 1E Page (193-04)

For drinkable water monitoring Range: from 0.01 up to 10 ppm Output signal: 4-20 mA Pressure limit: 0.5 bar as a maximum Unnecessary zero adjustment

Created on 27/09/2010 16:15 and updated on 10/04/2018 13:40

193-04

1E

Page
CC1
Free chlorine sensor, with isocyanuric acid 1E Starting Up Notice (193-06)

Created on 27/12/2010 15:18 and updated on 10/04/2018 15:26

193-06

1E

Starting Up Notice
VEP K4-PPH
Electrically actuated butterfly valves 1E Page (914-06)

ND 65 to ND 200 In-line pattern Electric actuator, Position index Manual operating for immediate action

Created on 08/12/2011 15:57 and updated on 10/04/2018 14:43

914-06

1E

Page
GSM module WITH CABINET
GSM and Wall mounting housing 1E Page (248-03)

• Compact cabinet IP 67 • Mains Power supply • Screw terminals

Created on 10/12/2019 13:51 and updated on 10/12/2019 13:56

248-03

1E

Page
TS 13
Plastic temperature probe, Pt 100 Ω 1E Page (613-01)

• Plastic probe • Materials: PVC, PP, PVDF • Sensor: Pt 100 Ω at 0 °C • Range: from -20 °C up to 140 °C

Created on 11/12/2019 16:45 and updated on 11/12/2019 16:46

613-01

1E

Page
SDD 910
Pressure relief valves 1E Page (910-01)

• All wet parts in plastic • Protection of pumps and piping • Body: PPG or PVDF • Unions: PVC, PP or PVDF • ND 10 and ND 15 • Adjustable trigger point: 0.5 ... 6 bar

Created on 18/12/2019 10:33 and updated on 18/12/2019 10:39

910-01

1E

Page
FS4
Tank top level indicator 1E Page (584-01)

Local indicator, Tank top fitting For liquids, with or without particles Materials: PVC or PP • Direct reading • Materials PVC, PPH • Magnetic pointer for level switches • For tanks and drums

Created on 10/10/2006 15:14 and updated on 11/12/2019 15:06

584-01

1E

Page
BAMOFLU 100
Flowsensor 1E Starting Up Notice (780-01)

Created on 28/05/2007 14:40 and updated on 10/04/2018 15:57

780-01

1E

Starting Up Notice
BCP 48
Programmable counter 1E Starting Up Notice (289-01)

Created on 06/09/2007 09:54 and updated on 10/04/2018 15:22

289-01

1E

Starting Up Notice
MNR 7 Ex
Magnetic float level controller 1E Starting Up Notice (550-03)

Created on 19/12/2008 17:53 and updated on 10/04/2018 15:41

550-03

1E

Starting Up Notice
BAMOBUL
Bubbling... state of the art for level measurement! 1E News ()

BAMOBUL is designed for a reliable and accurate measurement The bubbling measuring method is a non-age technique. It is still today, a serious alternative to ultra sonic transmitter, offering a trouble free use with foaming process and a long-term high...

Created on 21/12/2009 17:35 and updated on 10/04/2018 16:23



1E

News
CL4.1
Free chlorine sensor, at constant pH 1E Page (193-02)

For process water Range: 0.5 to 200 ppm Output signal: 4-20 mA Pressure limit: 1 bar as a maximum Unnecessary zero adjustment

Created on 15/10/2010 12:55 and updated on 17/12/2019 17:03

193-02

1E

Page
NIVOSTOP® / ACS
Level controller, drinkable water agreement 1E Page (523-01)

For use in drinkable water , Food industry applications ACS Certificate = sanitary certification For use in drinkable water Food industry applications Built-in ballast Standard cable lengths 5, 10 and 20 m ACS Certificate = sanitary certification

Created on 07/07/2011 09:49 and updated on 10/04/2018 14:01

523-01

1E

Page
VPP K4-PVDF
Pneumatically actuated butterfly valves, single / double acting 1E Starting Up Notice (913-09)

Created on 12/12/2011 17:43 and updated on 10/04/2018 16:05

913-09

1E

Starting Up Notice
NIVOSTOP® PR2
Heavy duty float level detector 1E Page (522-05)

• For sewage pumping/ lifting stations • Built-in counterweight • Robust design • High grade Neoprene cable • Cable length: 6, 10, 15, 20 m

Created on 11/12/2019 10:49 and updated on 11/12/2019 10:55

522-05

1E

Page
BMV
Metallic flow controllers with sided indicator 1E Page (721-01)

• Vertical mounting • Flow indicator with 1 adjustable contact • Material: Brass or AISI • Pressure limit up to 300 bar • Flow ranges within 0.1 ... 50 l/min

Created on 17/12/2019 11:25 and updated on 17/12/2019 11:32

721-01

1E

Page
CBT
Check valves 1E Page (950-03)

• Only one possible flow direction • Vertical or horizontal mounting • From ND 32 up to ND 300 With or without spring, Versions: Wafer or with loose flanges

Created on 18/12/2019 16:29 and updated on 18/12/2019 16:33

950-03

1E

Page
ATEX certified's products
for installation in dangerous zone 1E News ()

ATEX Certification's products implies a certification in the ISO model. We lay out via our deutch subsidiary company this capacity. All a range in your disposition.

Created on 08/10/2006 19:12 and updated on 11/04/2012 17:05



1E

News
BIF 6040
Ratemeter Totaliser 1E Starting Up Notice (282-01)

Created on 11/10/2006 17:28 and updated on 10/04/2018 15:21

282-01

1E

Starting Up Notice
MAXIMAT LW C
Leakage detection sensor 1E Starting Up Notice (555-03)

Created on 12/03/2007 14:29 and updated on 10/04/2018 15:42

555-03

1E

Starting Up Notice
TURBICUBE
In line turbidity transmitter 1E Starting Up Notice (444-01)

Created on 20/06/2007 14:19 and updated on 10/04/2018 15:32

444-01

1E

Starting Up Notice
TWS
Thermowells, welded body 1E Page (635-01)

• Body: welded tube • AISI 316 L, PVC, PPH, PVDF • Fittings: Threads: BSP or NPT ½'' ; NPT ¾'' Flanges: DN 32, 40 or 50

Created on 20/12/2007 14:35 and updated on 11/12/2019 16:55

635-01

1E

Page
LISA
Liquid Intrusion Safe Alarming System 1E Starting Up Notice (544-03)

Created on 10/04/2009 18:31 and updated on 10/04/2018 15:39

544-03

1E

Starting Up Notice
MAXIMAT LW VK
Leakage detection sensor 1E Starting Up Notice (555-08)

Created on 24/03/2010 10:38 and updated on 10/04/2018 15:44

555-08

1E

Starting Up Notice
PALINTEST POOLTEST 3
Photometer for chlorine and isocyanuric acid 1E Starting Up Notice (190-10)

Created on 06/12/2010 15:15 and updated on 10/04/2018 15:22

190-10

1E

Starting Up Notice
VPP K4-PVC
Pneumatically actuated butterfly valves, single / double acting 1E Page (913-03)

ND 65 to ND 200 In-line pattern Pneumatic actuator Single or double acting Position index Status NC or NO Standard compatibility: NAMUR VDI/VDE 3845 and ISO 5211  OPTIONS: Limit switch box Pilot valve

Created on 07/12/2011 11:51 and updated on 10/04/2018 14:38

913-03

1E

Page
VE3V S4-PPH
Electrically actuated 3-way ball valves 1E Starting Up Notice (914-05)

Created on 28/03/2012 16:46 and updated on 10/04/2018 16:08

914-05

1E

Starting Up Notice
OZ10
Ozone sensor 1E Page (193-22)

- For clear water or sea water - Highly resistant to surfactants - Temperature : up to 45 °C - Pressure: up to 1 bar

Created on 04/12/2019 16:46 and updated on 04/12/2019 16:56

193-22

1E

Page
LINEAR GRADUATED RULERS
1E Page (581-01)

- Metallic rulers for level indication - Mounting or vertical, or slope at 45° - Easy reading on large scale - Resistant to corrosion, climate strengths and seawater - Easy cleaning

Created on 11/12/2019 14:10 and updated on 11/12/2019 14:14

581-01

1E

Page
IDP SERIES
SPECIAL SCALES 1E Page (730-06)

Created on 17/12/2019 15:39 and updated on 17/12/2019 15:41

730-06

1E

Page
General Information
1E Category ()

Created on 23/09/2006 18:33 and updated on 27/03/2018 15:34



1E

Category
BAMOMATIC
Electromagnetic flow-meter 1E Page (775-01)

Electromagnetic Flowmeter independent of fluid density, temperature or pressure, the most competitive on the market

Created on 09/10/2006 16:13 and updated on 17/12/2019 16:43

775-01

1E

Page
MAXIMAT C
Compact overfill sensor 1E Page (555-01)

Capacitive, high frequency, fail-safe detection  For aggressive and conductive liquids  Positive active alarm  Auto diagnostic system and LED  Approvals: DIBT Z-65.13-294, for overfillingdetection WHG§19, and VLAREM II

Created on 13/02/2007 11:52 and updated on 10/04/2018 14:10

555-01

1E

Page
TRUBOMAT GAB
In line turbidity transmitter 1E Starting Up Notice (446-01)

Created on 31/07/2007 14:20 and updated on 10/04/2018 15:32

446-01

1E

Starting Up Notice
MAXIMAT SHRC
Measuring transducer 1E Starting Up Notice (555-06)

Created on 10/09/2008 16:01 and updated on 10/04/2018 15:43

555-06

1E

Starting Up Notice
MEMPRO Ex C
Hydrostatic level transmitter 1E Page (592-02)

Fill level monitoring in ATEX Ex area For flammable liquids No moving parts Accurate and reliable measurement Output signal 4-20 mA, 2 wires Free from fluid viscosity or conductivity Scales: up to 4000 mm ATEX certification

Created on 27/11/2009 10:59 and updated on 10/04/2018 14:22

592-02

1E

Page
CP2.1
Total chlorine sensor 1E Page (193-05)

- Water treatment, drinkable quality and sea water - Low incidence of pH changes - Surfactants: partial tolerance - Operating temperature 45 °C max. - Operating pressure 0.5 bar max.

Created on 27/09/2010 16:33 and updated on 04/12/2019 15:05

193-05

1E

Page
CD 7
Chlorine dioxide sensor 1E Starting Up Notice (193-11)

Created on 27/12/2010 15:25 and updated on 10/04/2018 15:26

193-11

1E

Starting Up Notice
VE2V S4-PVDF
Electrically actuated 2-way ball valves 1E Page (914-07)

ND 10 to ND 100 In-line pattern Electric actuator, Position index Manual operating for immediate action

Created on 08/12/2011 17:14 and updated on 10/04/2018 14:44

914-07

1E

Page
RDN 11
Intrinsic safety relay 1E Page (251-01)

• Intrinsic safety relay • Galvanic insulation • Protection for 1 contact or proximity sensor • Change over relay output

Created on 10/12/2019 14:05 and updated on 10/12/2019 14:12

251-01

1E

Page
TW
Thermowells 1E Page (635-02)

• Machined integral or welded • Large choice of materials • Process connections: Process: ½'', ¾''", 1" Welded fittings Flanges

Created on 11/12/2019 16:56 and updated on 11/12/2019 16:58

635-02

1E

Page
V186 – V86
Pressure relief valves 1E Page (911-04)

• Body in PVC, PP or PVDF • Diaphragm: in EPDM with PTFE coat • V186: Spigot ends from ND 10 up to ND 50 • V 18 : Spigot ends from ND 65 up to ND 100

Created on 18/12/2019 10:40 and updated on 18/12/2019 10:56

911-04

1E

Page
GNR 5 PVC
Level indicator 1E Page (571-01)

Local indicator, Level control Glass or transparent PVC tube Magnetic float: PP Connections: Flange or BSP threaded • Direct reading on site • Height: 40 to 500 cm • Wet parts: PVC, PPH • Seals: EPDM • Adjustable level switches

Created on 10/10/2006 15:32 and updated on 11/12/2019 13:56

571-01

1E

Page
BAMOPHOX 322
Resistivity / Conductivity 1E Starting Up Notice (322-01)

Created on 28/05/2007 14:45 and updated on 10/04/2018 15:28

322-01

1E

Starting Up Notice
RTM
Continuous level transmitter 1E Starting Up Notice (586-01)

Created on 14/09/2007 10:11 and updated on 10/04/2018 15:50

586-01

1E

Starting Up Notice
CONDUCTIVITY
Typical measuring ranges 1E Page (300-99)

Created on 22/12/2008 14:53 and updated on 10/04/2018 13:51

300-99

1E

Page
PHOXLOG: version 2.16
1E News ()

The software dedicated to the data logger BAMOPHOX is yet downloadable. Among new details, the inductive conductivity metre BAMOPHOX 322 TOR is included. Downloading: from the instructions manual page BAMOPHOX 106

Created on 21/12/2009 17:39 and updated on 10/04/2018 16:23



1E

News
GsM 24e
Modem GSM / GPRS 1E Page (248-01)

Compact module M2M applications Supply required: 5.5....32 V dc 3 Inputs, 1 output Including: Serial cable Antenna Software

Created on 28/10/2010 16:01 and updated on 10/04/2018 13:47

248-01

1E

Page
VP2V S4-PVC
Pneumatically actuated 2-way ball valves, single / double acting 1E Page (913-01)

• PVC Valves from ND 10 up to ND 100 • Pneumatic actuator Single or double acting • Position pointer • OPTIONS: Limit switches box Pilot valve

Created on 07/07/2011 13:07 and updated on 18/12/2019 11:14

913-01

1E

Page
SV61- BE41
Accessories for pneumatic actuators 1E Page (913-10)

• Pilot solenoid valves • Limit switches Box • Exhaust silencers • Exhaust dampers

Created on 27/12/2011 18:05 and updated on 18/12/2019 11:37

913-10

1E

Page
BAMOPHAR 107
BAMOPHAR 107 1E Page (107-01)

• Color touch screen • 2 existing scales: 0... 14 pH or ±1000 mV • Temperature compensation: Automatic or manual • 2 outputs 0/4-20mA (pH and T °C) • 4 relays (Thresholds, alarm and/or regulation) • Options: RS 422 /J-BUS + LOGGER...

Created on 04/12/2019 10:33 and updated on 11/03/2020 14:57

107-01

1E

Page
NIVOSTOP® - MEZZO
Float level regulator 1E Page (522-06)

• Regulation between two trigger points • Change-over microswitch • High switching power • Switching angle 120° • Cable lengths: 5, 10 and 20 m

Created on 11/12/2019 10:57 and updated on 11/12/2019 11:01

522-06

1E

Page
CDA
Flow controllers, metallic 1E Page (722-01)

• Operates in all positions • With 1 adjustable contact • Versions: Stainless steel or brass • Pressure: Up to 350 bar • Ranges: between 0.005 ...150 l/min

Created on 17/12/2019 11:34 and updated on 17/12/2019 11:42

722-01

1E

Page
PM 958
Liquid dosing tube 1E Page (958-01)

• Liquid dosing tube • Tube in transparent PVC • Dimensions: Custom made • Option: Manual valves

Created on 18/12/2019 16:35 and updated on 18/12/2019 16:38

958-01

1E

Page
Short Programme
1E Category ()

The company BAMO Mesures SAS: European manufacturer of sensors and instruments for the monitoring and analysis of liquids BAMO has expertise in: Analysis and measuring of fluids, pH, chlorine, conductivity water hardness, turbidity and dissolved oxygen...

Created on 08/10/2006 19:48 and updated on 12/04/2018 09:56



1E

Category
BAMOPHOX 759
Venturi channel flow calculator 1E Starting Up Notice (759-02)

Created on 22/06/2007 16:15 and updated on 10/04/2018 15:56

759-02

1E

Starting Up Notice
MEMPRO
Hydrostatic level transmitter 1E Starting Up Notice (592-01)

Created on 26/12/2007 15:30 and updated on 10/04/2018 15:51

592-01

1E

Starting Up Notice
NIVOIL
Alarm system for oil-water separators 1E Starting Up Notice (531-01)

Created on 21/04/2009 14:11 and updated on 10/04/2018 15:37

531-01

1E

Starting Up Notice
Achemasia 2010
8th International Exhibition-Congress on Chemical Engineering and Biotechnology 1E News ()

We shall exhibit between the 1 and 4 June 2010 in Beijing, our products in Achemasia 2010, the 8th International Exhibition-Congress on Chemical Engineering and Biotechnology

Created on 26/04/2010 11:41 and updated on 10/04/2018 16:20



1E

News
BAMOSOFT Smart
Water hardness monitor 1E Page (375-01)

Water hardness controller for water softening systems Preset limit value at 10% of raw water hardness BAMOSOFT Smart monitors a preset residual water hardness threshold value from the outlet of the water softener system. Threshold value is fixed at...

Created on 06/12/2010 15:21 and updated on 10/12/2019 15:47

375-01

1E

Page
VP2V S4-PPH
Pneumatically actuated 2-way ball valves, single / double acting 1E Page (913-04)

ND 10 to ND 100  In-line pattern  Pneumatic actuator  Single or double acting, Position index Status NC or NO Standard compatibility: NAMUR VDI/VDE 3845 and ISO 5211  OPTIONS : Limit switch box Pilot valve

Created on 08/12/2011 09:52 and updated on 10/04/2018 14:39

913-04

1E

Page
VEP K4-PPH
Electrically actuated butterfly valves 1E Starting Up Notice (914-06)

Created on 28/03/2012 16:49 and updated on 10/04/2018 16:09

914-06

1E

Starting Up Notice
BAMOPHAR 194
Disinfectant monitoring and control 1E Page (194-02)

• Color touch screen • Input for 1 sensor 4-20 mA or 0-2 V • Existing scales: Free & total chlorine, chlorine dioxide Ozone, hydrogen peroxide, peracetic acid • 1 Input for Pt100 sensor • 2 Outputs 0/4-20mA (ppm or g/l and °C) • 4...

Created on 10/12/2019 12:42 and updated on 10/12/2019 12:45

194-02

1E

Page
SFA, modular series
Sets and kits 1E Page (583-05)

• For tanks with large heights • Easy carriage • Short delivery time • Level indicator protected by PVC tube • All sets and kits for assembly on site

Created on 11/12/2019 14:54 and updated on 11/12/2019 14:55

583-05

1E

Page
Z60 / IDP-A
Flow transmitter for IDP-A 1E Page (730-07)

• Flow-rate transmitter • For IDP-A, with magnetic diver • Output signal: 4-20 mA (3-wire) • Already set in factory • Plug in connector

Created on 17/12/2019 15:43 and updated on 17/12/2019 15:57

730-07

1E

Page
FFG
Turbine Flowmeter 1E Page (784-01)

Totalization and low flow measure  Compact equipment  PVDF, Polysulfon and arnite execution  Easy dismantling  Measure range: 6 to 720 l/h  Accuracy ±1%  Frequency output: high resolution  Connection 1/4" GM

Created on 09/10/2006 16:20 and updated on 10/04/2018 14:35

784-01

1E

Page
MAXIMAT VK C
Compact overfill sensor 1E Page (555-02)

Float level detection  For aggressive and non electrically conductive liquids  Positive active alarm  Auto diagnostic system and LED indication  Approvals: DIBT Z-65.13-294, for overfilling detection WHG§19, and VLAREM II

Created on 13/02/2007 14:31 and updated on 10/04/2018 14:11

555-02

1E

Page
CP1
Immersion probe for turbidity control 1E Page (425-01)

ON/OFF turbidity control PVC probe, IP68 Optical measurement in Infra Red wavelengths Detection: from 50 to 1300 FAU or from 600 to 3000 FAU  Immersion depth of 10 m as a maximum Fitting and configuration easy with our TRUBOMAT GS3 controller

Created on 30/03/2007 13:37 and updated on 10/04/2018 13:56

425-01

1E

Page
9336
pH - ORP Immersion probes 1E Starting Up Notice (130-01)

Created on 06/08/2007 17:34 and updated on 10/04/2018 15:15

130-01

1E

Starting Up Notice
BAMOMATIC
Electromagnetic Flowmeter 1E Starting Up Notice (775-01)

Created on 14/10/2008 18:04 and updated on 10/04/2018 15:57

775-01

1E

Starting Up Notice
MEMPRO Ex C
Hydrostatic level transmitter 1E Starting Up Notice (592-02)

Created on 27/11/2009 11:11 and updated on 10/04/2018 15:51

592-02

1E

Starting Up Notice
CC1
Sensor for free chlorine with stabilizers 1E Page (193-06)

Closed cell with diaphragm, 3 electrodes For swimming pool water monitoring Water sample may not content surface-active additives. Range: 0.01 to 10 ppm Output signal: 4-20 mA Pressure limit: 0.5 bar Temperature limit: 1...45 °C - For swimming pools...

Created on 27/09/2010 16:53 and updated on 04/12/2019 15:30

193-06

1E

Page
AS2 & AS3
Chlorine dioxide and free chlorine sensors 1E Starting Up Notice (193-13)

Created on 27/12/2010 15:58 and updated on 10/04/2018 15:27

193-13

1E

Starting Up Notice
VE3V S4-PVDF
Electrically actuated 3-way PVDF ball valves 1E Page (914-08)

• PVDF valves from ND10 up to ND50 • Radial mounting and dismounting • Electric actuator with position pointer and manual operating for emergency

Created on 08/12/2011 17:32 and updated on 18/12/2019 15:12

914-08

1E

Page
PKK
Multitask relay 1E Page (251-02)

• Galvanic isolation • input 4-20 mA or potential free contact • Intrinsic safety • Settings on relay outputs • Power supply to sensor

Created on 10/12/2019 14:14 and updated on 10/12/2019 14:17

251-02

1E

Page
CDP
Paddle flow controller 1E Page (710-01)

• 1 Reed contact N.O. / N.C. • Stainless steel or brass versions • Low pressure drop • Fittings: On tee up to ND50 or BSP ½''

Created on 17/12/2019 09:58 and updated on 17/12/2019 10:09

710-01

1E

Page
DHV 712-R
Pressure relief valve 1E Page (911-05)

• Protection of pumps and pipings • Body: PVC-U, PP or PVDF • Diaphragm: EPDM coated with PTFE • Fittings from ND 10 to ND 50

Created on 18/12/2019 10:58 and updated on 18/12/2019 11:03

911-05

1E

Page
User Manuals
1E Category ()

Created on 28/09/2006 22:50 and updated on 27/03/2018 16:27



1E

Category
MAGTOP
Level indicator 1E Page (560-01)

Indicators allow an instantaneous level liquid reading in a tank, even if this one is opaque

Created on 10/10/2006 15:41 and updated on 11/12/2019 13:41

560-01

1E

Page
MEMPRO
Hydrostatic level transmitter 1E Page (592-01)

Universal use in open tanks Reliable operation, even with aggressive, viscous, contaminated and crystallising liquids. The measuring cell is not in contact with the medium. Range: up to 10 m WC Wetted parts: PVC, PP, EPDM or stainless steel Measuring...

Created on 29/05/2007 15:47 and updated on 10/04/2018 14:21

592-01

1E

Page
BAMOPHOX 319 ML-DB
Resistivity Metre 1E Starting Up Notice (319-02)

Created on 17/09/2007 17:38 and updated on 10/04/2018 15:28

319-02

1E

Starting Up Notice
WM24
Floor leakage alarm device 1E Page (544-05)

Floor standing detector , compact unit Without moving parts Built-in relay Cable output, 5 m long PVC cable

Created on 22/12/2008 18:30 and updated on 10/04/2018 14:08

544-05

1E

Page
IFAT 2008 - Munich 5-9 May 2008
15th International Trade Fair for Water - Sewage - Refuse - Recycling 1E News ()

It was once more a successful exhibition "Environmental solutions" with 120000 visitors for 2560 exhibitors. Our booth BAMO-IER in the middle of numerous and talented manufacturers received congratulations from them as well as from visitors. The 2/3 of...

Created on 21/12/2009 17:45 and updated on 10/04/2018 16:22



1E

News
GsM 24e
Modem GSM / GPRS 1E Starting Up Notice (248-01)

Created on 28/10/2010 16:25 and updated on 10/04/2018 15:21

248-01

1E

Starting Up Notice
VP2V S4-PVC
Pneumatically actuated 2-way ball valves, single / double acting 1E Starting Up Notice (913-01)

Created on 07/07/2011 14:34 and updated on 10/04/2018 16:01

913-01

1E

Starting Up Notice
Accessories for pneumatic actuators
1E Starting Up Notice (913-10)

Created on 27/12/2011 18:18 and updated on 10/04/2018 16:06

913-10

1E

Starting Up Notice
9337
Immersion probe with built-in temperature sensor 1E Page (130-02)

• Protective holder • Built-in temperature sensor Pt100 • Simplified calibration routine • For 1 electrode (PG 13.5 sealing) • Adjustable immersion depth • Fastening by flange or collar • PVC construction

Created on 04/12/2019 10:45 and updated on 04/12/2019 10:51

130-02

1E

Page
NIVOSTOP® ECO
Float level regulator 1E Page (522-07)

• For clear, non-aggressive liquids • Economic model, easy to install • Switching angle: 45° • Regulation between 2 levels • PVC cable, 10 m long

Created on 11/12/2019 11:04 and updated on 11/12/2019 11:09

522-07

1E

Page
CDV
Flow controllers & indicators, metallic 1E Page (722-02)

• Operates in all positions • Flow indicators, plus 1 flow contact • Versions: Stainless steel or brass • Pressure max. 16 bar • Flow ranges from 0.005 up to 150 l/min

Created on 17/12/2019 11:48 and updated on 17/12/2019 11:57

722-02

1E

Page

« 1 2 3 »

Technical & Commercial support's main contacts
Ask a QUOTATION online
BAMO Mesures SAS
22 Rue de la Voie des Bans
Parc d'activités de la Gare
95100 ARGENTEUIL France
Tel : +33 (0)130 258 332
Fax : +33 (0)134 101 605

Email : info@bamo.fr
Company n° 314 055 864
SIC : 2651 B

URL : http://www.bamocontrol.co.uk
Designed and hosted by CARIMEDIA since 1998
© 1998-2024 All rights reserved - Disclaimer