Preview | There are 42 results for | Relevancy |
![]() |
Data processors 200 ![]() Archives/ Created on 01/04/2012 15:07 and updated on 03/04/2018 11:26 |
200![]() Category |
![]() |
Water hardness 375 ![]() Archives/ Created on 04/02/2022 12:12 and updated on 04/02/2022 12:13 |
![]() Category |
![]() |
Turbidity![]() Archives/ Created on 04/02/2022 12:16 and updated on 04/02/2022 12:16 |
![]() Category |
![]() |
Oxygen![]() Archives/ Created on 04/02/2022 12:21 and updated on 04/02/2022 12:21 |
![]() Category |
![]() |
Level 500 ![]() Archives/ Created on 01/04/2012 15:14 and updated on 03/04/2018 11:26 |
500![]() Category |
![]() |
NIVOSTOP® - SS2 / HYP Level controller, all in Hypalon ![]() Compatibility with basic, leak acid solutions and other aggressive chemicals Restrictions: due to the cable made of HYPALON and additives Adjustable ballast Maximal pressure 5.5 bar Maximal temperature 95°C Created on 26/11/2009 12:44 and updated on 10/04/2018 16:32 |
520-02![]() Page |
![]() |
Flow 700 ![]() Archives/ Created on 01/04/2012 15:15 and updated on 03/04/2018 11:27 |
700![]() Category |
![]() |
9500 In-line electrode holders under pressure ![]() • pH or ORP measurement • Construction: AISI 316 L • Pressure max. 16 bar • Temperature max. 110 °C • Fittings PG13.5 or BSP 1/2'' • For electrodes with fitting PG 13.5 • Process connections ND 15 to 32 mm Created on 08/02/2007 16:03 and updated on 04/12/2019 11:46 |
142-01![]() Page |
![]() |
BAMOPHOX 192 Free Chlorine monitoring with Open cell amperometric method ![]() Alphanumeric back lighted LCD display Friendly using menu Ranges from 0 to 5 mg/l for free chlorine -20...+160°C for temperature 2 analogical outputs 0/4-20mA, galvanic insulated 3 relay outputs (Normally Open contacts) 1 relay output for system... Created on 03/01/2007 11:10 and updated on 10/04/2018 13:38 |
192-02![]() Page |
![]() |
GA 1 – GA 2 – GA 11 – GA 5 Armatures for turbidity control ![]() Sensor fixture with emitter and receiver To use with the turbidity controller TRUBOMAT GS3 DN 15 to DN 200 In-line mounting or as a by-pass Construction PVC, PPH, Stainless steel Sensor fixture with emitter and receiver To use with the turbidity... Created on 21/02/2007 17:24 and updated on 10/04/2018 13:55 |
421-01![]() Page |
![]() |
MUDLine® TGS Portable sludge level measuring instrument ![]() Battery powered Mud level detection in primary and secondary clarifier, thickener and other applications Useful also in rotten black sludge Sludge level monitoring in small sewage plants Immersion depth: 10 m as a maximum Field portable device Sludge... Created on 03/11/2006 11:22 and updated on 10/04/2018 13:56 |
426-01![]() Page |
![]() |
MUDLine® TGS Portable sludge level measuring instrument ![]()
Created on 03/11/2006 11:28 and updated on 10/04/2018 15:31 |
426-01![]() Starting Up Notice |
![]() |
BAMOPHOX 106 pH-Meter and mV-Meter ![]()
Created on 16/02/2007 10:37 and updated on 10/04/2018 14:50 |
106-01![]() Starting Up Notice |
![]() |
9090 Temperature compensation probe ![]() • For mounting on holders 9200, 9500 et 9346 • Sensor Pt 100 Ω at 0 °C • Versions: Simplex or Duplex • Fitting PG 13.5 Created on 26/02/2007 10:23 and updated on 04/12/2019 12:18 |
150-02![]() Page |
![]() |
pH and ORP ACCESSORIES Accessories ![]()
Created on 26/02/2007 11:32 and updated on 04/12/2019 13:57 |
160-01![]() Page |
![]() |
BAMOTOP 281 Frequency converter ![]() • For any pulse emitter such as: BAMOFLU, BAMOTUR, Micro-stream, FFG, DF 140, Counters M, BAMOMATIC (12 V) • Input modes to configure • Range: 1 ... 25000 Hz • Galvanic insulated output • Current: 0/4-20 mA or 0-5/10 V • Response time to set... Created on 16/05/2007 10:16 and updated on 10/12/2019 14:22 |
281-01![]() Page |
![]() |
BAMOPHOX 319 ML-DB Resistivity Metre ![]() 2 independent sensors Input 1: range 0...20 MΩ Input 2: scalable range 0...20 MΩ / 0...2 MΩ Dedicated probes and sensors With Factor probe C = 0.01, 0.1, 1 and 10 2 adjustable analog output 0/4-20 mA 3 relay outputs (NO contact) Wall mounting IP 65 Created on 28/02/2007 09:33 and updated on 10/04/2018 13:51 |
319-02![]() Page |
![]() |
BAMOPHOX 322 Resistivity / Conductivity ![]() Monitor and controller MΩ - mS Programmable scales: 0...200 Ω up to 0...20 MΩ 0...2 μS up to 0...20 mS TOR version, 0...2 mS up to 0...2000 mS Convenient probes: With cell contant, 10 ; 1 ; 0.1 ; 0.01 or with TOR sensor Automatic or manual... Created on 09/10/2006 11:09 and updated on 10/04/2018 13:52 |
322-01![]() Page |
![]() |
TCS 3020 Series Inductive conductivity probe in NORYL ![]() Process measurement on line or by immersion For waste liquids Wide range of applications Large scales: from 0-2 to 0-2000 mS Probe material: NORYL • Range: from 10 μS/cm up to 2000 mS/cm • Material: NORYL • Temperature max. 105 °C • Low... Created on 28/02/2007 10:35 and updated on 10/12/2019 15:36 |
364-01![]() Page |
![]() |
TRUBOMAT GS 3 Turbidity controller ![]() ON/OFF turbidity Controller No effect of day light Output relay Adjustable delay Dysfunction indicator Created on 22/02/2007 18:05 and updated on 04/02/2022 12:17 |
410-01![]() Page |
![]() |
BAMOPHOX 436 Turbidity monitor ![]() Alphanumeric back lighted LCD display 2 models available: Panel mounting 72 x 144 (436E) Wall mounting IP 65 (436M) 3 relay outputs (Normally Open contacts) 1 relay output for system alarm 2 analogical outputs 0/4-20mA Scales NTU, FAU, mg/L, g/L, FNU ... Created on 15/02/2007 11:26 and updated on 04/02/2022 12:18 |
436-01![]() Page |
![]() |
TURBICUBE In line turbidity transmitter ![]() Drinking water plants Raw and waste water Phase separation, filtration Measuring range: 0.01...1000 FNU Output signal: 0/4-20 mA Immediate connection to BAMOPHOX monitor, data logger and regulator Flow-through in-line turbidimeter acc. ISO 7027... Created on 15/02/2007 11:05 and updated on 10/04/2018 13:57 |
444-01![]() Page |
![]() |
MNR 7 Magnetic float level controller ![]() Available in PVC – PPH - PVDF Up to 4 bi-stable change over contacts High switch power capacity Independent from density. Foam or vapors do not interfere Option for a continuous measurement Specific documentation: 586 = RTM/MNR7 Available in PVC –... Created on 26/02/2007 11:15 and updated on 10/04/2018 14:09 |
550-01![]() Page |
![]() |
MNR 7 - 316L Stainless steel magnetic float level controller ![]() Construction: stainless steel 316 Up to 4 bi-stable change over contacts High switch power capacity Independent from density. Foam or vapors do not interfere Option for a continuous measurement, see our specific documentation 586 about RTM/MNR7 Created on 26/02/2007 10:58 and updated on 10/04/2018 14:09 |
550-02![]() Page |
![]() |
MNR 7 Ex Magnetic float level controller ![]() Construction: stainless steel 1.4571 (316 Ti – AISI) Up to 4 bi-stable change over contacts ATEX II 1/2 G - EEx ib IIC T4 Construction: stainless steel 1.4571 (316 Ti – AISI) Up to 4 bi-stable change over contacts ATEX II 1/2 G - EEx ib IIC T4 Created on 26/02/2007 10:47 and updated on 10/04/2018 14:10 |
550-03![]() Page |
![]() |
MAXIMAT LW CN-SDR Leakage detection transmitter ![]() Capacitive, high frequency, fail-safe detection For aggressive and conductive liquids Two sensors Positive active alarm Auto diagnostic system and LED indicator WHG §19, approval DIBt-No.: Z-65.40-316 Created on 13/02/2007 15:13 and updated on 10/04/2018 14:11 |
555-04![]() Page |
![]() |
MAXIMAT LWC-B Leakage detection sensor ![]() Floor standing leakage detector Capacitive, high frequency, fail-safe detection For aggressive and electrically conductive liquids Positive active alarm Auto diagnostic system and LED indicator Created on 13/02/2007 15:47 and updated on 10/04/2018 14:12 |
555-05![]() Page |
![]() |
MAXIMAT SHR CS Measuring transducer ![]() Alarm signal relay for leakage or overfill transmitters Designed for overfill and leakage sensors MAXIMAT®C, MAXIMAT®VK.., MAXIMAT®LW.., CAPSYTRON SFL DIBT Approval Designed for overfill and leakage sensors MAXIMAT®C, ... Created on 13/02/2007 16:05 and updated on 10/04/2018 14:12 |
555-06![]() Page |
![]() |
MAXIMAT TC4 Signaling device 4 sensor inputs ![]() 4 surveying channels for leakage or overfill transmitters 4 surveying channels For compact overfill or leakage sensors MAXIMAT® C, MAXIMAT® VK..., MAXIMAT® LW... Microprocessor controlled Automatic sensor detection and survey Sensors and... Created on 26/02/2007 11:22 and updated on 10/04/2018 14:12 |
555-07![]() Page |
![]() |
MAXIMAT LW VK Leakage detection sensor ![]() Float level fail-safe detection For aggressive and non electrically conductive liquids Positive active alarm Auto diagnostic system and LED indication when in use with a SHR C transducer Approvals: DIBT Z-65.40-272, for leakage detection,... Created on 13/02/2007 17:48 and updated on 10/04/2018 14:13 |
555-08![]() Page |
![]() |
CST / KRC Relays for maximat and capsytron ![]() Relays for compact overfill sensors MAXIMAT C.., leakage sensors , MAXIMAT LW-C... and CAPSYTRON… level switches, pumps protection Created on 26/02/2007 09:58 and updated on 10/04/2018 14:13 |
555-09![]() Page |
![]() |
BRK 60 - BRT 60 Magnetic level contacts ![]() Switching power of 60 VA Bistable switch, NC either NO, 3 wires IP 55 Housing in ABS For tubes of diameter 32, 40 and 63 mm High temperature version up to 200°C • Switching power: 60 VA • Bi-stable, change-over contact • IP 55 casing, in ABS •... Created on 27/03/2007 14:12 and updated on 11/12/2019 15:37 |
585-02![]() Page |
![]() |
SFA Cable and pulleys level indicator ![]() Easy to install Convenient to viscous, aggressive and waste liquids High, long or small tanks Adjustable level switches Kits for ordering • Easy to install • Convenient to viscous, aggressive, waste liquids • Up to 6 m high tanks • Adjustable... Created on 14/03/2007 17:13 and updated on 11/12/2019 14:40 |
583-01![]() Page |
![]() |
SFA/E Cable and pulleys , gastight level indicator ![]() Gas tight cable operated level indicator Vapours confining Fluid protection from contamination Convenient to viscous, aggressive, wasted liquids Adjustable on site, easy to install Even for high tanks • For storage tanks • Gastight indicator •... Created on 15/03/2007 18:17 and updated on 11/12/2019 14:43 |
583-02![]() Page |
![]() |
SFA series Parts ![]() Unit: %, height, Volume, Mass/Weight Any ruler with a length over 4.6 m is delivered in 2 parts. (the fitting for assemble is included) . A drawing for acceptance is submitted before we manufacture the ruler. A complete set for your level... Created on 15/03/2007 18:25 and updated on 11/12/2019 14:50 |
583-03![]() Page |
![]() |
SFA / CR Level indicator, reduced path ![]() • Convenient to a wide range of liquids • Easy to install; Simple to use • Reduced graduated ruler • Guided float • Adjustable level switches Created on 15/03/2007 18:34 and updated on 11/12/2019 14:52 |
583-04![]() Page |
![]() |
FLOATS – COUNTERWEIGHTS Actuators for level switches ![]()
Created on 28/03/2007 08:53 and updated on 11/12/2019 15:49 |
585-03![]() Page |
![]() |
BAMOPHOX 759 Venturi channel flow calculator ![]() Programmable for level, instantaneous flow, daily volume, permanent cumulated volume Also within memorized curves for VENTURI, V or U overflow weir Input signal: 0/4-20 mA Output signal: 0/4-20 mA 4 adjustable limit relays Wall mounting housing IP... Created on 22/03/2007 18:01 and updated on 10/04/2018 14:28 |
759-02![]() Page |
![]() |
BAMOFLU 100 Flowsensor ![]() The flowing fluid maintains in rotation the five blades rotor and each blade has a built-in magnet, not in contact with the fluid Created on 09/10/2006 16:01 and updated on 10/04/2018 14:34 |
780-01![]() Page |
![]() |
100/150 P 600 Bourdon tube pressure gauge “all stainless steel” acc. EN 837.1 ![]() CASE DIAMETER 100 or 150 mm ACCURACY Class 1 SCALE RANGES From 0...0.6 bar to 0...1600 bar PRESSURE LIMITS DURING OPERATION Continuously: steady pressure up to F.S. value Fluctuating pressure: 90% of F.S. value Temporarily: 1.3 x F.S. value for... Created on 15/06/2010 15:32 and updated on 10/04/2018 14:35 |
812-05![]() Page |
![]() |
DP800 Differential pressure gauge ![]() Case diameter: 100 or 150 mm Accuracy: Class 1.6 Scale ranges: From 0...60 mbar to 600 mbar...25 bar Overpressure: 100 bar on one input at a time Static pressure limit: 200 bar as a maximum, all scales Temperature limits Ambient: -25 to +65°C Process:... Created on 09/09/2010 11:40 and updated on 10/04/2018 14:35 |
812-14![]() Page |
![]() |
SWITCHES FOR GAUGES![]()
Created on 23/06/2010 10:58 and updated on 10/04/2018 14:36 |
812-17![]() Page |