Preview | There are 150 results for | Relevancy |
![]() |
EchoTREK Ultrasonic Level Transmitter on open channel ![]() Compact level transmitter Measuring height up to 6 m Dead zone of 25 cm Adjustable range for the 4-20 mA output signal Programmable relay output (autodiagnostic or alarm) Created on 09/10/2006 17:08 and updated on 10/04/2018 14:27 |
755-03![]() Page |
![]() |
BAMOPHOX 450 Dissolved oxygen monitoring ![]() Alphanumeric back lighted LCD display Friendly using menu Scales: 0...100% or mg/L through configuration Temperature compensation: automatic or manual 2 analogical outputs 0/4-20mA galvanic insulated 3 independent relay outputs (N.O. contacts) 1 alarm... Created on 10/05/2007 13:40 and updated on 04/02/2022 12:21 |
450-02![]() Page |
![]() |
9360 Auto cleaning probe ![]()
Created on 07/08/2007 17:21 and updated on 10/04/2018 15:18 |
145-01![]() Starting Up Notice |
![]() |
SFA Cable and pulley level system ![]()
Created on 06/11/2008 18:42 and updated on 10/04/2018 15:47 |
583-01![]() Starting Up Notice |
![]() |
BAMOPHOX New pH-metre from BAMO ![]() - pH/ORP programmable monitor and regulator - Alphanumeric back lighted LCD display - Friendly using menu - Scales: 0 - 14 pH and ± 1000 mV through configuration - Temperature compensation automatic or manual - 2 analogical outputs 0/4-20mA galvanic... Created on 21/12/2009 17:00 and updated on 10/04/2018 16:25 |
![]() News |
![]() |
BAMOPHOX 194 Amperometric sensors signal monitor ![]() Amperometric signal monitor Parameters according to the sensor in use: Free chlorine, Total chlorine, Chlorine dioxide, Ozone, Hydrogen peroxide, Peracetic acid Alphanumeric back lighted LCD display Friendly using menu 1 sensor input (4-20 mA or 0/-2... Created on 27/09/2010 17:18 and updated on 10/04/2018 13:44 |
194-01![]() Page |
![]() |
VORTEX Flow sensor for water ![]() Flow rate on hot industrial water, drinkable water, demineralised water Measuring independent from temperature Nominal diameters from ND 8 to 25 mm No moving parts Output signal: Analogue 4-20 mA or pulses Drinking water approval: KTW, W270, WRAS Created on 19/01/2011 14:11 and updated on 10/04/2018 14:34 |
777-01![]() Page |
![]() |
VP2V S4-PPH Pneumatically actuated 2-way ball valves, single / double acting ![]()
Created on 12/12/2011 17:30 and updated on 10/04/2018 16:03 |
913-04![]() Starting Up Notice |
![]() |
TCL S50 series Inductive conductivity, PEEK probe ![]() - Measuring range from 10 μS/cm up to 2000 mS/cm - Construction: PEEK - Wide chemical compatibility - Temperature max. 125 °C - Low fouling probe - Built-in Pt100 sensor Created on 10/12/2019 15:41 and updated on 10/12/2019 15:43 |
364-05![]() Page |
![]() |
OPTIFLUX Flow indicator ![]() • Indication of flow with a rotor • Mounting in all positions • Up to 16 bar; Up to 100 °C • Cleaning without dismounting • For liquids • Fittings: BSP ¼'' ... 1 ½'' female threads • Brass version or stainless steel Created on 17/12/2019 10:39 and updated on 17/12/2019 10:43 |
719-01![]() Page |
![]() |
VVDV Angle seat valve ![]() • Mounting in any position • Direct maintenance in-line • Fine adjustment of flow rate Created on 18/12/2019 15:36 and updated on 18/12/2019 15:41 |
930-01![]() Page |
![]() |
MNR 6 Magnetic level controllers ![]() Available in PVC-PPH, PPH, PVDF and stainless steel 316 L 1 or 2 bi-stable change over contacts Small dimensions Lightly affected by specific weight variations 4-20 mA continuous transmitter (option RTM MNR6) • Versions: PVC, PPH, PVDF or AISI 316 •... Created on 10/10/2006 16:50 and updated on 11/12/2019 13:35 |
551-01![]() Page |
![]() |
ES 2001 Amplifier relay ![]() - Protection of Reed contact - Outputs: 2 change over contacts, voltage free; 5A / 250 V AC / 500 VA - Status relay display - Regulation between two trigger points - Adjustable time delay Created on 13/06/2007 10:38 and updated on 10/12/2019 14:03 |
250-02![]() Page |
![]() |
Pt 100 Ω PROBES OVERVIEW![]()
Created on 20/12/2007 09:46 and updated on 10/04/2018 14:23 |
610-01![]() Page |
![]() |
ES 5000 Relay for resistive level detection ![]() For all electrical conductive liquids Suitable for level or leakage detection Adjustable sensitivity and timer, selection of action mode Self diagnostic with instant alarm (LED) for: Short circuit on the loop detection, Loop detection cable break off... Created on 26/01/2009 14:13 and updated on 10/04/2018 14:08 |
544-06![]() Page |
![]() |
ACHEMA 2009 - Hall 10.1 - Stand B38 Frankfurt am Main, May 11 to 15 ![]() We show off our complete range and all our new products on our booth BAMO-IER GmbH Relevant lines: - MAXIMAT: certification acc.WHG§19 - TRUBOMAT: complete line for turbidity monitoring - NIVOMAT: level measurement with float, high resolution -... Created on 22/12/2009 14:56 and updated on 10/04/2018 16:21 |
![]() News |
![]() |
AS2/ AS3 Free chlorine and chlorine dioxide sensors ![]() Opened cell, 3 electrodes For industrial hot water, drinkable water, cooling water, process water Without diaphragm Range: 0.01 to 5 ppm Output signal: 4-20 mA Pressure limit: 8 bar Temperature limit: 5...70 °C • For hot sanitary water, drinkable... Created on 25/11/2010 18:16 and updated on 04/12/2019 16:31 |
193-13![]() Page |
![]() |
MAXITOP LW C Leakage detection probe ![]()
Created on 09/11/2011 16:39 and updated on 10/04/2018 15:45 |
556-03![]() Starting Up Notice |
![]() |
NIVOSTOP SG2 Level controller ![]()
Created on 03/02/2012 12:23 and updated on 10/04/2018 15:35 |
520-03![]() Starting Up Notice |
![]() |
BMW 102 Hand held pH-meter ![]() • Portable, ergonomic and lightweight model • Display of pH and Temperature • Replaceable pH and temperature sensors • Supplied ready to use Created on 04/12/2019 14:00 and updated on 04/12/2019 14:08 |
180-01![]() Page |
![]() |
MAGTOP D Level indicator - ATEX or/ and P.E.D. ![]() • Version ATEX or complying to Pressure Equipment Directive • Direct reading on two-color ruler • Temperature up to 450 °C • Pressure up to 250 bar • Options: Level switches, Analogue signal transmitter, graduated ruler in % Created on 11/12/2019 13:43 and updated on 11/12/2019 13:46 |
560-03![]() Page |
![]() |
DUM Flow controllers, metallic ![]() • Operates in all positions • Blind controller, 1 contact • Independent of pressure • Pressure up to 300 bar • Flow ranges from 0.2 up to 250 l/min Created on 17/12/2019 14:39 and updated on 17/12/2019 14:47 |
725-01![]() Page |
![]() |
pH - ORP Industrial type electrodes ![]() Combined electrodes Universal S7-head, Connection: 13.5 Pg thread • Suitable with mainly all pH-meters • Combined electrodes (measurement + reference) • For connectors type S7 • Electrolyte: gel type Created on 09/10/2006 10:26 and updated on 04/12/2019 12:09 |
150-01![]() Page |
![]() |
NIVOSTOP SS2 Float switches ![]() Large range For waste water and sewage pumping systems, sumps shafts etc... With built-in ballast With different cables With different shapes • Mercury-free • Fair cost • Easy to install • Compatible with chemicals • Switching current 1 mA... Created on 21/03/2007 08:47 and updated on 11/12/2019 10:40 |
520-01![]() Page |
![]() |
TURBISENS Turbidity transmitter, Immersion Probe ![]()
Created on 26/06/2007 18:29 and updated on 10/04/2018 15:32 |
443-01![]() Starting Up Notice |
![]() |
LAS Resistivity monitor ![]() Easy to use for demineralised water monitoring Expanded scale from 0 to 2 MΩ Contact output Adjustable sound alarm Created on 25/06/2008 16:45 and updated on 10/04/2018 13:51 |
315-02![]() Page |
![]() |
MW10 & MW11 Pocket photometers for chlorine ![]()
Created on 15/12/2010 12:06 and updated on 10/04/2018 15:23 |
190-11![]() Starting Up Notice |
![]() |
VPP K4-PVDF Pneumatically actuated butterfly valves, single / double acting ![]() ND 65 to ND 200 In-line pattern Pneumatic actuator Single or double acting, Position index Status NC or NO Standard compatibility: NAMUR VDI/VDE 3845 and ISO 5211 OPTIONS Limit switch box Pilot valve Created on 08/12/2011 14:33 and updated on 10/04/2018 14:41 |
913-09![]() Page |
Archives![]()
Created on 29/03/2012 10:07 and updated on 27/03/2018 16:09 |
![]() Category |
![]() |
BAMOWIZ Digital and graphical display ![]() • Graphic color touch-sensitive screen • Multilingual end-user interface • 2 (3) Inputs 4-20 mA • Setting of 8 thresholds for 2 (3) relays • Units: set on keyboard • 1 (0) Output 4-20 mA • 1 (0) Serial interface RS485 MODBUS • Graphic... Created on 10/12/2019 13:13 and updated on 04/02/2022 12:09 |
217-01![]() Page |
![]() |
BAMONIV TPS Hydrostatic level transmitter ![]() • Level measurement of aggressive liquids • Measuring cell: ceramic (99.9 %) • Accuracy: 0.35 % (option: 0.25 %) • Measuring ranges up to 50 m Water Column • Body: PVDF or PP Created on 11/12/2019 16:00 and updated on 11/12/2019 16:05 |
591-03![]() Page |
![]() |
DEBITBAC V-notch weir systems ![]() Overflow weir Standard: ISO 1438/1-1980 Measuring range: 1 m 3 /h to 400 m 3 /h V-angle from 20° to 90° Materials: PVC or PE • Flow-rate from 1 to 80 m³/h • V-notch angle from 20° to 100° • Custom made on request • Ready to use • In... Created on 09/10/2006 17:19 and updated on 17/12/2019 16:24 |
755-02![]() Page |
![]() |
pH & ORP electrodes Industrial application electrodes ![]()
Created on 07/08/2007 17:25 and updated on 10/04/2018 15:19 |
150-01![]() Starting Up Notice |
![]() |
Option: 4 stages regulation processor pH/mV Meter BAMOPHOX 106 ![]() For pH or ORP (mV) process operation Up to 4 regulation stages Scales: 0-14 pH and ± 1000 mV Temperature compensation: Manual from menu configuration Automatic with a Pt 100 Ohm 2 analog outputs as 0/4-20 mA, galvanic insulated 4 relay outputs: S1 /... Created on 19/11/2008 09:49 and updated on 18/12/2019 17:23 |
106-02![]() Page |
![]() |
BAMO acquires a German Company ![]() To confirm its activities development on fluids control, BAMO Mesures SAS acquires the First of January 2006 the well-known Company IER Mess und Regeltechnik GmbH. IER in a few words: 35 years of experience in the German Market Turn over of 2 millions... Created on 21/12/2009 17:09 and updated on 10/04/2018 16:24 |
![]() News |
![]() |
RDP 906 Pressure reducing valves ![]() A pressure reducing valve RDP 906 maintains constant the pressure downstream, at the adjusted value. Pressure: Class PN 10 (at 20°C) Set up range: 1 to 9 bar Temperature limits PPH: 10 to 70°C PVC: 10 to 50°C Dimensions: ND 10 ... ND 25 Body: PPG... Created on 15/03/2011 11:10 and updated on 10/04/2018 14:36 |
906-02![]() Page |
![]() |
VP3V S4-PPH Pneumatically actuated 3-way ball valves, single / double acting ![]()
Created on 12/12/2011 17:33 and updated on 10/04/2018 16:03 |
913-05![]() Starting Up Notice |
![]() |
Achema 2012 World Exhibition Congress on Chemical Engineering, Environmental Protection and Biotechnology ![]() 18 - 22 June Hall 11, booth G3 We show off our complete range and all our new products on our booth BAMO-IER GmbH. Relevant lines: New series MAXIMAT CX, certification acc.WHG§19 TRUBOMAT: complete line for turbidity monitoring SDD and RDP new lines of... Created on 04/04/2012 20:10 and updated on 10/04/2018 16:19 |
![]() News |
![]() |
BAMOPORT MI 415 Handheld turbidity-meter ![]() • Measuring scales: 0.50 to 50 FNU 50 to 1000 FNU • Easy to use • Supplied ready-to-use with a rigid case Created on 10/12/2019 16:02 and updated on 10/12/2019 16:08 |
448-02![]() Page |
![]() |
OPTIFLUX ECFV Flow indicator ![]() • Direct view of the flow of a liquid • Vertical or horizontal mounting • Ranges up to 60 I/min • Fittings: ¼"... 1" BSP F. • Body: Nickel-plated brass Created on 17/12/2019 10:45 and updated on 17/12/2019 10:56 |
719-02![]() Page |
![]() |
VM2V S4 FDC Manually operated 2-way ball valves and limit switches ![]() • Radial mounting and dismounting • 100 % full flow • 2 limit switches Created on 18/12/2019 15:43 and updated on 18/12/2019 15:54 |
934-03![]() Page |
![]() |
BSM 501 - BSM 515 Level switches with micro-switch ![]() High power switching Reverse and bi-stable switch IP 65 housing • High switching power • Bistable switch • Protection: IP 65 Created on 10/10/2006 17:10 and updated on 11/12/2019 15:31 |
585-01![]() Page |
![]() |
EF / EFC Level electrodes for wells ![]() For well and bore-hole Compactness Material: Stainless steel • Compact electrodes • All stainless steel • For conductive liquids • Supplied with or without cable Created on 13/06/2007 14:15 and updated on 11/12/2019 13:23 |
542-02![]() Page |
![]() |
TS 11 Temperature probe with Pt 100 Ω sensor ![]() Pt 100 Ω at 0 °C Measure scale Wetted parts S.Steel Industrial head • Sensor Pt 100 Ω at 0 °C • Range from -50 to +250 °C • Stem and fitting in AISI 316 L • Head in aluminum alloy or in plastic Created on 20/12/2007 09:58 and updated on 11/12/2019 16:37 |
611-01![]() Page |
![]() |
ES 5000 Relay for resistive level detection ![]()
Created on 04/02/2009 18:25 and updated on 10/04/2018 15:40 |
544-06![]() Starting Up Notice |
![]() |
J.A.R. Heavy-duty Cat & Mouse level indicator ![]() So many technologies such as radars, ultrasonic transmitters, are offering sophisticated measuring systems that do not answer to simple requests! This is an opportunity for BAMO to redesign a level indicator. A strong experience helped us to build up... Created on 22/12/2009 14:59 and updated on 10/04/2018 16:20 |
![]() News |
![]() |
WP7 Hydrogen peroxide sensor ![]() For swimming pool water, drinkable water, cooling water, process water Range: from 0.001 up to 100.0 g/L Output signal: 4-20 mA Sensor affords surfactants Pressure limit: 1 bar as a maximum Unnecessary zero adjustment Created on 26/11/2010 16:34 and updated on 10/04/2018 13:42 |
193-25![]() Page |
![]() |
AQUAPLUS Dissolved oxygen probe ![]() Measuring up to 50 mg/l or up to 500% in saturation Numeric signal compensated in temperature and salinity Low maintenance No water flow required Interference free towards suspended solids AQUAPLUS™ Probe holder PVC tube Ø 50 Standard length 2... Created on 18/11/2011 15:43 and updated on 10/12/2019 16:14 |
451-01![]() Page |
![]() |
NIVOSTOP SS2 W & KW Switch level floats ![]()
Created on 21/02/2012 13:11 and updated on 10/04/2018 15:35 |
520-01![]() Starting Up Notice |
![]() |
ClO₂⁺ Photometer for chlorine and chlorine dioxide ![]() • For drinking water and hot water networks • Concentration of free chlorine, total chlorine and chlorine dioxide • Measurement ranges: Chlorine from 0.01 to 5 mg/l Chlorine dioxide from 0.02 to 10 mg/l • Supplied ready to use Created on 04/12/2019 14:21 and updated on 04/12/2019 14:33 |
190-12![]() Page |
![]() |
GNR5 - Glass reading tube Level indicator ![]() • Direct reading on the tank • Height from 300 up to 2000 mm • Materials: Glass and brass • Seals: Silicon rubber • Option: Adjustable level contacts Created on 11/12/2019 13:47 and updated on 11/12/2019 13:50 |
570-01![]() Page |
![]() |
DUG Flow controller with indicator, metallic ![]() • Operates in all positions • Indicator, plus 1 adjustable contact • Versions: Stainless steel or brass • Pressure up to 10 bar • Flow range: 0.2 ... 250 l/min Created on 17/12/2019 14:48 and updated on 17/12/2019 14:55 |
725-02![]() Page |
![]() |
BAMOCHLOR 192 Open Cell Free chlorine assembly for swimming pools ![]() Opened cell, copper / platinum For swimming pool Free active chlorine monitoring Range: 0 to 5 ppm For BAMOPHOX 192 Pressure limit: 0.2 bar Temperature limit: 0...40 °C Self cleaning Open cell amperometric method Electrochemical cell Self cleaning... Created on 09/10/2006 10:41 and updated on 10/04/2018 13:38 |
192-01![]() Page |
![]() |
EVEREST 214 2 channels measuring amplifier for 0/4-20 mA sensors ![]() 4 Limit value Relays for 1 or/and 2 input signal The forth relay may be used as a Timer Adjustable hysteresis 2 inputs 4-20 mA, scalable from 0 to 25 mA Power supply to the sensors Created on 28/06/2007 15:42 and updated on 10/04/2018 13:46 |
232-03![]() Page |
![]() |
BamoPHOX TOR 322 E - M Conductivity meter, scales: 0 ...2 /...20 /...200 /...2000 mS ![]()
Created on 26/06/2008 15:04 and updated on 10/04/2018 15:29 |
322-03![]() Starting Up Notice |
![]() |
ITU 402 - ITU 412 Panel mounting indicators ![]() Inputs: mA, V, Pt 100, Ni 100, TC Main power input: 21.6...253 VAC / 50-60 Hz or 19.2...300 VDC Sensor power supply: 15...25 VDC / 0...20 mA Housing: IP65, black polycarbonate, 48 x 96 mm Outputs relays: 2 change over contacts 230 VAC Analogue: 0/4-20... Created on 16/11/2009 17:26 and updated on 10/12/2019 13:20 |
222-03![]() Page |
![]() |
SDD 911 Pressure relief valves - ND 10 to ND 25 ![]() A pressure relief valve SDD 911 limits the static pressure to a maximal settled value by opening the outlet (to the discharge line) when the pressure is overriding. Pressure: Class PN 10 (at 20°C) Set up range: 0.5 to 10 bar Temperature limits PPH:... Created on 25/06/2010 15:45 and updated on 10/04/2018 14:37 |
911-03![]() Page |
![]() |
CL4 Free chlorine sensor, at constant pH ![]()
Created on 20/12/2010 11:04 and updated on 10/04/2018 15:25 |
193-02![]() Starting Up Notice |
![]() |
VEP FE-PVC Electrically actuated butterfly valves ![]() ND 65 to ND 200 In-line pattern Electric actuator, Position index Manual operating for immediate action • PVC Valve from ND 50 up to ND 200 • In-line pattern • Electric actuator; Position index; Manual operating for emergency Created on 08/12/2011 15:29 and updated on 18/12/2019 15:03 |
914-03![]() Page |
Disclaimer![]()
Created on 29/03/2012 10:29 and updated on 29/03/2012 10:29 |
![]() Page |
![]() |
BMPC 4896 Wall mount cabinet for 48x96 mm indicators ![]() • IP 55 Wall mount cabinet • Grey polycarbonate • Dimensions 159x149x151 mm • With 5 cable glands Created on 10/12/2019 13:26 and updated on 10/12/2019 13:31 |
222-05![]() Page |
![]() |
BAMOSONIC Ultrasonic level transmitter for liquids ![]() • Measuring range from 0.2 to 8 m (liquids) • Non-contact level measurement • Power supply by 4-20 mA Loop • IP67 Ingress protection • Option : Plug-in display Created on 11/12/2019 16:07 and updated on 11/12/2019 16:16 |
597-06![]() Page |
![]() |
TP 805 Pressure transducer ![]() • Compact and robust construction • Output signal: 4-20 mA; 2-wire • Pressure: 0 ... 2.5 barg up to 25 barg • AISI 316 Fitting: ½" G or ¼" G • Ceramic diaphragm Created on 18/12/2019 09:43 and updated on 18/12/2019 10:02 |
805-04![]() Page |
![]() |
VENTURI CHANNEL DEBITFLO Flow rate measurement in open channel ![]() Manufactured Venturi channels are dedicated for flow rate measurement in open flumes, and totalization on effluents Created on 09/10/2006 17:26 and updated on 10/04/2018 14:27 |
755-01![]() Page |
![]() |
BF 1200 SERIES Conductivity measuring cell ![]() • Cell factor K = 1 • Fitting PG 13.5 • Body: Glass tube Ø 12 mm • Platinum measuring elements Created on 18/05/2007 10:15 and updated on 10/12/2019 15:30 |
361-01![]() Page |
![]() |
9054 pH Connector Accessories ![]()
Created on 10/08/2007 10:47 and updated on 10/04/2018 15:19 |
160-01![]() Starting Up Notice |
![]() |
Option: 4 stages regulation processor pH/mV Meter BAMOPHOX 106 ![]()
Created on 25/11/2008 14:02 and updated on 10/04/2018 14:52 |
106-02![]() Starting Up Notice |
DIRECTIVE 2002/95/CE RoHS![]() Dear Partners, We also are concerned with the environmental protection and the RoHS requirements 2002/95/CE. What is the objective? The directive RoHS shall limit the use of toxic and harmful materials in the manufacture of electric and electronic... Created on 21/12/2009 17:21 and updated on 21/12/2009 17:21 |
![]() News |
![]() |
RDP 906 Pressure reducing valves ![]()
Created on 15/03/2011 11:17 and updated on 10/04/2018 16:00 |
906-02![]() Starting Up Notice |
![]() |
VPP K4-PPH Pneumatically actuated butterfly valves, single / double acting ![]()
Created on 12/12/2011 17:36 and updated on 10/04/2018 16:04 |
913-06![]() Starting Up Notice |
![]() |
IFAT 2012![]() We shall be exhibiting our products in Munich at IFAT 2012, the world's leading trade fair for water, sewage, waste and raw materials management. 07 th to 11 th of May, 2012 - New Munich trade fair centre - Hall 5, booth 506. Besuchen Sie uns auf... Created on 04/04/2012 20:13 and updated on 10/04/2018 16:18 |
![]() News |
![]() |
BAMOPHAR 451 Dissolved oxygen monitor ![]() • Dissolved oxygen measurement • Scales: 0.01 to 50 mg/l or 0 to 500 % • 1 Input for AQUAPLUS probe • 2 Analogue outputs 0/4-20mA • 4 Relay outputs (Thresholds and alarm) • OPTIONS: Extension terminal for 2nd measuring parameter Created on 10/12/2019 16:16 and updated on 10/12/2019 16:18 |
451-03![]() Page |
![]() |
BV - BR Metallic flow controller & indicator ![]() • Vertical mounting • 1 Indicator + 1 adjustable contact • Material: stainless steel or brass • Pressure limit 10 bar • Flow ranges within 0.1 ... 50 l/min Created on 17/12/2019 10:59 and updated on 17/12/2019 11:06 |
720-01![]() Page |
![]() |
VM3V S4 Manually operated 3-way ball valves, industrial series ![]() • Secure and lockable handle • Radial mounting and dismounting • 100% full flow Created on 18/12/2019 15:56 and updated on 18/12/2019 16:11 |
935-01![]() Page |
![]() |
BAMOPHOX 450 Dissolved oxygen monitoring ![]()
Created on 14/06/2007 11:35 and updated on 10/04/2018 15:33 |
450-02![]() Starting Up Notice |
![]() |
TEMPERATURE PROBES WITH Pt 100 Ω SENSOR![]()
Created on 20/12/2007 14:02 and updated on 10/04/2018 14:23 |
610-02![]() Page |
![]() |
NivOil® / 230 V AC Alarm system for oil-water separators ![]() Designed for the monitoring of hydrocarbon fluids separators, the converter NivOil® may be connected to 1, 2, or 3 sensors. The 3 sensors may be connected to any input. Hydrocarbon fluid layer thickness sensor to detect when the maximum thickness... Created on 12/02/2009 13:51 and updated on 10/04/2018 14:02 |
531-01![]() Page |
![]() |
NivOil® / 12 V dc Alarm system for oil-water separators ![]() Low power consumption 10...27 V dc power supply input Zone 0 ATEX certified (Zone 2 for the alarm device location) Solar powered or standard electric battery Energy saving mode adjustable (control frequency adjustable from 6 min up to 9 days) 3... Created on 07/01/2010 18:07 and updated on 10/04/2018 14:03 |
531-02![]() Page |
![]() |
PRESSURE GAUGES![]()
Created on 26/11/2010 16:59 and updated on 10/04/2018 15:58 |
812-04![]() Starting Up Notice |
![]() |
BAMOPHOX 216 Data monitor – Data recorder ![]() Alphanumeric back lighted LCD display Parameters and programming: Input sensor signal, scale Measuring range Displayed unit (m, cm, %, ppm, mg, g) Scale from 0.001 to 9999 Wall mounting IP 65 or panel mounting 3 relay outputs, 2 analogical outputs... Created on 18/11/2011 16:14 and updated on 10/04/2018 13:45 |
216-01![]() Page |
![]() |
VE3V S4-PVC Electrically actuated 3-way ball valves ![]()
Created on 28/03/2012 16:28 and updated on 10/04/2018 16:07 |
914-02![]() Starting Up Notice |
![]() |
CL4.2 Free chlorine sensor, at constant pH ![]() • Water treatment • pH must be constant • No tolerance to surfactants • Temperature 45 °C max. • Pressure 1 bar max. Created on 04/12/2019 14:40 and updated on 04/12/2019 14:53 |
193-03![]() Page |
![]() |
GNR 6 Level indicator ![]() • Direct reading on site • Measuring tube O.D. 63 mm • Wet parts: PVC and PPH • Stop valves, included • Options: Level switches, graduated ruler Created on 11/12/2019 13:58 and updated on 11/12/2019 14:01 |
572-01![]() Page |
![]() |
DUM/A Flow controller with indicator, metallic ![]() • Operates in all positions • Indicator, plus 1 adjustable contact • Versions: Stainless steel or brass • Pressure: up to 300 bar • Flow ranges: 0.2 ... 250 l/min Created on 17/12/2019 14:57 and updated on 17/12/2019 15:04 |
725-03![]() Page |
![]() |
BS - BC Conductivity and resistivity probes ![]() Resistivity and Conductivity probes Cell factors 0.1 and 0.01 Reliability and sturdiness Construction: Stainless Steel and PTFE, PVC Also to be use with the BAMOPHOX • Conductivity and resistivity probes • Cell factors 0.1 and 0.01 • Reliability... Created on 09/10/2006 10:55 and updated on 10/12/2019 15:24 |
360-01![]() Page |
![]() |
TRUBOMAT GAB In-line turbidity system ![]() • Continuous turbidity measurement according to ISO 7027: 90° Scattered light, 180° Attenuated light • 2 emitters, 1 receiver • Measuring ranges: 0.01 ... 20 FNU 0.1 ... 1000 FNU / FAU • Output signal: 4-20 mA (4-wire) • Fitting: Flanges DIN... Created on 23/03/2007 13:32 and updated on 10/12/2019 16:01 |
446-01![]() Page |
![]() |
EVERETS 214 2 channels measuring amplifier for 0/4-20 mA sensors ![]()
Created on 28/06/2007 15:54 and updated on 10/04/2018 15:20 |
232-03![]() Starting Up Notice |
![]() |
GNR 5 / PVC Level indicator controller ![]()
Created on 26/06/2008 15:14 and updated on 10/04/2018 15:46 |
571-01![]() Starting Up Notice |
![]() |
MEMPRO S6 Hydrostatic level controller ![]() Convenient for level controls on non-pressurised tank 4 switching points, adjustable over all the measuring range Convenient for aggressive and loaded fluids even viscous or / and sticky fluids Range: up to 10 m Water Column Reliable, without mobile... Created on 19/11/2009 16:36 and updated on 10/04/2018 14:22 |
592-03![]() Page |
![]() |
CS2.3 Free chlorine sensor, without effect from pH changes ![]()
Created on 22/12/2010 14:03 and updated on 10/04/2018 15:25 |
193-04![]() Starting Up Notice |
![]() |
VE2V S4-PPH Electrically actuated 2-way ball valves ![]() ND 10 to ND 100 In-line pattern Electric actuator, Position index Manual operating for immediate action Created on 08/12/2011 15:38 and updated on 10/04/2018 14:43 |
914-04![]() Page |
![]() |
BXNT Intrinsic safety converter ![]() • Approval IIC ATEX II (1) G/D • Main power 230 V AC • Input and output: 4-20 mA • DIN rail mounting Created on 10/12/2019 13:33 and updated on 10/12/2019 13:40 |
235-01![]() Page |
![]() |
EasyTREK Ultrasonic level transmitter ![]() • Height range 0.15 to 18 m, for liquids • Non-contact level measurement • HART® 7 protocole • Output signal 4-20 mA • IP 68 (allows accidental immersion) Created on 11/12/2019 16:17 and updated on 11/12/2019 16:29 |
598-01![]() Page |
![]() |
A32 Needle valve ![]() • Made from metal bar stock • Operating pressure: 413 bar Max. • Temperature: 240 °C Max. Created on 18/12/2019 10:04 and updated on 18/12/2019 10:11 |
816-01![]() Page |
![]() |
BAMOBUL Air bubbling level transmitter ![]() BAMOBUL is designed for Venturi channel or Weir plates (documentation 755-01) water level measurements up to 500 mm Created on 09/10/2006 17:43 and updated on 10/04/2018 14:28 |
758-02![]() Page |
![]() |
BIR 7110 Panel mounting indicator ![]() Inputs: Thermocouples, Pt 100 Ohm Easy configuration Display 5 digits Housing 48 x 96 mm Front IP65 Main power 95…265 V AC Min. / Max. memory Programmable ramp: 9 segments Options: Output for signal as a 4-20 mA Supplementary relay... Created on 18/05/2007 10:49 and updated on 10/04/2018 16:31 |
221-02![]() Page |
![]() |
DEBITFLO Flow rate measurement in open channel ![]()
Created on 29/08/2007 10:57 and updated on 10/04/2018 15:53 |
755-01![]() Starting Up Notice |
![]() |
MNR 7 Magnetic float level controller ![]()
Created on 18/12/2008 10:18 and updated on 10/04/2018 15:41 |
550-01![]() Starting Up Notice |
![]() |
New terminal heads for BAMO![]() This year 2006, are appearing new perspectives for BAMO and part of them are some red head housings, the most visible changes. They will fit at least all our field instrumentation: flow, turbidity, ph, conductivity probes and more... Thanks to these red... Created on 21/12/2009 17:23 and updated on 10/04/2018 16:24 |
![]() News |
![]() |
SDD 912 Pressure relief valves - ND 32 to ND 50 ![]() Pressure relief valves SDD 912 limits the static pressure to a maximal settled value by opening the outlet (to the discharge line) when the pressure is overriding. All wetted parts in plastic Protection of pumps and process lines Affordable cost... Created on 20/05/2011 10:46 and updated on 10/04/2018 14:37 |
912-02![]() Page |
![]() |
VP2V S4-PVDF Pneumatically actuated 2-way ball valves, single / double acting ![]()
Created on 12/12/2011 17:39 and updated on 10/04/2018 16:04 |
913-07![]() Starting Up Notice |
![]() |
NIVASWITCH Vibrating fork level detector ![]() • Detection of level for liquids • Continuous monitoring • Operating even with turbulences • Unnecessary calibration routine • Operating even with suspended solids Created on 11/12/2019 10:27 and updated on 11/12/2019 10:32 |
513-03![]() Page |
![]() |
BR Metallic flow controllers ![]() • Vertical mounting • 1 adjustable contact • Material: stainless steel or brass • Pressure limit: up to 300 bar • Flow ranges within 0.1 ... 50 l/min Created on 17/12/2019 11:07 and updated on 17/12/2019 11:15 |
720-02![]() Page |
![]() |
VM2V CR Manually operated 2-way ball valves, water series ![]() • Radial mounting and dismounting • 100% full flow • Maintenance free Created on 18/12/2019 16:13 and updated on 18/12/2019 16:20 |
938-03![]() Page |
![]() |
BAMOPHOX 106 pH-Meter and mV-Meter ![]() The BAMOPHOX 106 offers high flexibility on use mixing different built-in programmes for regulation, thresholds, temperature compensation, and alarms Created on 02/10/2006 12:11 and updated on 18/12/2019 17:23 |
106-01![]() Page |
![]() |
9400 On-line holder for pH or ORP electrode ![]() • On-line holders for 1 electrode • For full piping • Materials: PPH or PVDF • Mounting: screw fitting 3/4" G • Version for inserting and removing the electrode (PG 13.5) with full pipe Created on 15/06/2007 14:35 and updated on 04/12/2019 11:34 |
141-01![]() Page |
![]() |
TS 12 Temperature probe with Pt 100 Ω sensor ![]() - Sensor: Pt 100 Ω at 0 °C - Range from -50 °C up to +250 °C - Stem in AISI 316 L - Water-tight cable output Created on 20/12/2007 14:20 and updated on 11/12/2019 16:42 |
612-01![]() Page |
![]() |
JAR Level gauge ![]() Stainless steel Cat & Mouse Level indicator with metallic parts Wide scale Graduated in %, m3, L Long height possible Protected pulleys with a no jump system Sections of 1500 mm, adjustable total length • Metallic level indicator • Height up... Created on 12/02/2009 14:25 and updated on 11/12/2019 14:17 |
582-01![]() Page |
![]() |
BAMOBOX SOLAR (BBS) Solar powered alarm unit for oil-water separators ![]() A complete system BBS will power an alarm unit NivOil® 10...27 V DC when no main power supply exists in the field. Autonomous complete system Field installation Solar panel powered and battery Pole clamp fitting or wall mounting Battery protection... Created on 11/02/2010 15:47 and updated on 11/12/2019 12:56 |
531-03![]() Page |
![]() |
SDD 911 Pressure relief valves - ND 10 to ND 25 ![]()
Created on 26/11/2010 17:06 and updated on 10/04/2018 16:00 |
911-03![]() Starting Up Notice |
![]() |
BAMOPHOX 451 Dissolved oxygen monitor ![]() Display and control Logger included Recording on memory card (up to 150 000 records) Phoxlog software included Alphanumeric back lighted LCD display Friendly using menu Data-logger on MMC card 1 input for sensor AQUAPLUS Scales: 0 to 500% or in mg/L 2... Created on 25/11/2011 17:48 and updated on 04/02/2022 12:22 |
451-02![]() Page |
![]() |
VEP K4-PVC Electrically actuated butterfly valves ![]()
Created on 28/03/2012 16:38 and updated on 10/04/2018 16:07 |
914-03![]() Starting Up Notice |
![]() |
CS4 Free chlorine sensor ![]() - Treatments of Fresh water and sea-water - Surfactants: partial tolerance - Low incidence of pH changes - Temperature: 45 °C max. - Pressure: 3 bar max. Created on 04/12/2019 15:32 and updated on 04/12/2019 15:45 |
193-07![]() Page |
![]() |
GNR 5 / INOX Level indicator - Controller ![]() • Direct reading • Construction: AISI 316 L and glass • C to C: Up to 2000 mm Created on 11/12/2019 14:02 and updated on 11/12/2019 14:05 |
575-01![]() Page |
![]() |
IDP / PDP Fittings - Flanges - Seals ![]()
Created on 17/12/2019 15:05 and updated on 17/12/2019 15:22 |
730-04![]() Page |
![]() |
BIR 9000 Panel mounting indicator ![]() Inputs: 4-20 mA, 0-10 mA, 0-10 V, 1-5 V Easy configuration Display 5 digits Housing 48 x 96 mm Front IP65 Main power 95…265 V AC Integrated sensor supply Min. / Max. values in memory Programmable ramp: 9 segments Created on 29/06/2007 11:54 and updated on 10/04/2018 16:31 |
222-02![]() Page |
![]() |
BIR 4000 Panel mounting indicator ![]() Analogic signal input, mA or V, DC Display 3 1⁄2 digits, red LED 14 mm height Small sized housing, 48x96x60 mm Front protection IP65 Removable screw connectors Main power supply 115 to 230 V – 50/60 Hz Power supply to sensor 24 V DC Optional 2 alarm... Created on 30/06/2008 13:44 and updated on 10/04/2018 16:30 |
220-01![]() Page |
![]() |
MEMPRO S6 Hydrostatic level controller ![]()
Created on 19/11/2009 16:47 and updated on 10/04/2018 15:51 |
592-03![]() Starting Up Notice |
![]() |
AMPEROMETRIC SENSORS![]() • Free chlorine • Total chlorine • Chlorine dioxide • Hydrogen peroxide • Peracetic acid - Wide measuring ranges - Limits up to 70 °C and 8 bar - Unnecessary zero adjustment - Reliable measuring signal - Built-in temperature compensation... Created on 27/09/2010 16:07 and updated on 04/12/2019 14:38 |
193-01![]() Page |
![]() |
CP 2.1 Total chlorine sensor, measuring free from pH changes ![]()
Created on 27/12/2010 15:15 and updated on 10/04/2018 15:25 |
193-05![]() Starting Up Notice |
![]() |
VE3V S4-PPH Electrically actuated 3-way ball valves ![]() ND 10 to ND 50 In-line pattern Electric actuator, Position index Manual operating for immediate action Created on 08/12/2011 15:47 and updated on 10/04/2018 14:43 |
914-05![]() Page |
![]() |
GsM 25e Modem GSM / GPRS ![]() • Remote information report • 2G enclosure for supervision and alarm • 3 Inputs / 1 Output • Set up software included Created on 10/12/2019 13:45 and updated on 10/12/2019 13:50 |
248-02![]() Page |
![]() |
MUDSENS Sludge level probe ![]() • Ultrasonic probe • Level monitoring of sludge in sedimentation tanks • Advanced algorithm • Output 4-20 mA: representative of sludge level • Cleaning with compressed air • User-friendly menu Created on 11/12/2019 16:31 and updated on 11/12/2019 16:34 |
599-02![]() Page |
![]() |
V182 – V82 Pressure reducing valves ![]() • Body : PVC, PP or PVDF • Diaphragm: in EPDM with PTFE coat • V182: Spigot ends from ND 10 up to ND 50 • V 82 : Spigot ends from ND 65 up to ND 100 • Gauge 0-10 bar, with built-in gauge guard Created on 18/12/2019 10:24 and updated on 18/12/2019 10:31 |
906-03![]() Page |
![]() |
BIR 8004 SERIE Numerical Indicator 4 Normaly Open Contacts ![]() Imput 4 - 20 mA 4 setting NO contacts Supply 230 V - 50/60 Hz Simplified setting Display +/- 2000 pts Display 3 1/2 digits LCD 12,5 mm Pannel mounting IP 55 Removable wiring connectors Sensor supply 230 V Output NO relays contacts Adjustable hyteresis... Created on 09/10/2006 18:01 and updated on 10/04/2018 16:31 |
222-01![]() Page |
![]() |
BAMOPHOX 436 Turbidity monitor ![]()
Created on 23/05/2007 18:04 and updated on 10/04/2018 15:31 |
436-02![]() Starting Up Notice |
![]() |
BCP 48 Programmable counter ![]() Universal and simple Double back-lighted LCD display Main counter 8 digits Totalizer Second counter 6 digits Batch counter with two pre-setting 4 programming mode Supply sensor 24 V DIN 48 x 48 enclosure box Created on 06/09/2007 09:29 and updated on 10/04/2018 13:49 |
289-01![]() Page |
![]() |
MNR 7 Stainless steel Stainless steel magnetic float level controller ![]()
Created on 19/12/2008 17:12 and updated on 10/04/2018 15:41 |
550-02![]() Starting Up Notice |
![]() |
MUDLINE Sludge level controller ![]() Perfect control of sludge level in sedimentation basin. Easy, quick and accurate measurement New answers for operators of WWTP to their needs of reliable information on sludge levels. The MUDLINE is an innovation on these applications: - Autonomous -... Created on 21/12/2009 17:28 and updated on 10/04/2018 16:23 |
![]() News |
![]() |
VP3V S4-PVDF Pneumatically actuated 3-way ball valves, single / double acting ![]()
Created on 12/12/2011 17:41 and updated on 10/04/2018 16:05 |
913-08![]() Starting Up Notice |
![]() |
NIVOSTOP® / C Float level detector ![]() • For aggressive liquids • Cable in FEP, seal in FPM, body in PP • Temperature max. 100 °C • Built-in counterweight • Standard cable lengths: 5, 10 & 20 m Created on 11/12/2019 10:41 and updated on 11/12/2019 10:48 |
520-04![]() Page |
![]() |
SIG 4.0 Analogue transmitter for flow controllers ![]() • For flow controllers • Output: 4 ... 20 mA or 0 ... 10 V • Accuracy: ±10 % FS • Already set in factory Created on 17/12/2019 11:17 and updated on 17/12/2019 11:23 |
720-10![]() Page |
![]() |
BV 91 - BV 95 Vent valves ![]() • Air inlet and outlet controls • Body: PVC, PP or PVDF • From ND 10 up to ND 80 • BV 91 free ball valve, for tank ventilation • BV 95 ball valve, spring assistance, for tank ventilation & vacuum breaking Created on 18/12/2019 16:21 and updated on 18/12/2019 16:25 |
949-02![]() Page |
![]() |
9200 In-line holders for 1 to 3 electrodes, pH or ORP ![]() pH or ORP continuous flow cells For 1 to 3 electrodes pH, mV PVC or PPH material Various process connections available • Holder for 1, 2 or 3 electrodes • Construction: PVC or PPH • Process fitting: Union ND 20, diam. 25 mm Created on 05/10/2006 17:31 and updated on 04/12/2019 11:17 |
140-01![]() Page |
![]() |
9423 In-line probe electrode holder ![]()
Created on 15/06/2007 17:26 and updated on 10/04/2018 15:18 |
141-01![]() Starting Up Notice |
![]() |
TS 16 Temperature sensor ![]() Pt 100 Ω at 0 °C Measurement range -200 ...+600 °C Stainless steel stem Waterproof cable output Created on 20/12/2007 14:29 and updated on 10/04/2018 14:25 |
616-01![]() Page |
![]() |
MAXITOP Compact overfill sensor ![]() Universal use for electrically conductive, non-flammable water endangering liquids According WHG § 19 in Germany, the series is called MAXIMAT® C. No moving parts Process connection BSP 2", PVC, sliding Stem PEHD: Ø 40 mm Adjustable immersion... Created on 25/03/2009 14:56 and updated on 10/04/2018 14:15 |
556-01![]() Page |
![]() |
MAXITOP LWC Leakage detection probe ![]() Leakage sensor Universal use for electrically conductive, non-flammable water endangering liquids According WHG § 19 in Germany, the series is called MAXIMAT® LW-C. Stem: PEHD, Ø 40 mm (Ø 25 on request) With fastening angle and adjustable... Created on 10/03/2010 15:12 and updated on 10/04/2018 14:15 |
556-03![]() Page |
![]() |
Pooltest 3 Photometer for chlorine and isocyanuric acid ![]() • For swimming pools • Measuring ranges Chlorine from 0.01 to 5 & 10 mg/l Isocyanuric acid from 2 to 200 mg/l pH from 6.5 to 8.4 • Delivered ready to use Created on 06/12/2010 15:06 and updated on 04/12/2019 14:19 |
190-10![]() Page |
![]() |
VP3V S4-PVC Pneumatic 3-way ball valves single or double acting ![]() ND 10 to ND 50 In-line pattern Pneumatic actuator Single or double acting Position index Status NC or NO • PVC Valves from ND 10 up to ND 50 • Pneumatic actuator Single or double acting • Position pointer • Options: Limit switches box Pilot... Created on 07/12/2011 11:38 and updated on 18/12/2019 11:21 |
913-02![]() Page |
![]() |
VE2V S4-PPH Electrically actuated 2-way ball valves ![]()
Created on 28/03/2012 16:42 and updated on 10/04/2018 16:08 |
914-04![]() Starting Up Notice |
![]() |
OZ7 Ozone sensor ![]() - Drinkable water, sea water - Surfactants: partial tolerance - Temperature: 45 °C max. - Pressure: 1 bar max. Created on 04/12/2019 16:33 and updated on 04/12/2019 16:44 |
193-21![]() Page |
![]() |
JEPA 580 Level gauge Electro-pneumatic, autonomous ![]() • For compatible liquids (diesel, water, ...) • Displays in cm or Volume • For any kind of tanks • Battery operated • Height max.: Diesel 3 m; Water 2.5 m Created on 11/12/2019 14:06 and updated on 11/12/2019 14:08 |
580-02![]() Page |
![]() |
IDP Plastic flow indicator ![]() • Direct reading • All wet parts in plastics • Measuring tubes: PVC or Polysulfone • Ranges: Up to 60 m³/h Specific scales for Air, HCl, NaOH, etc. • Options: Adjustable contacts, ruler with 4-20 mA transmitter Created on 17/12/2019 15:24 and updated on 17/12/2019 15:35 |
730-05![]() Page |
![]() |
RTM Continuous level transmitter ![]() Signal output: 4-20 mA Step: 10 mm The RTM is adapted to our level indicators MAGTOP, SFA, MNR 6 and MNR 7. Continuous level transmitter Output 4-20 mA or Ohm Accuracy: 10 mm Direct mounting above the tank Available for MAGTOP and SFA Created on 27/03/2007 14:20 and updated on 10/04/2018 14:20 |
586-01![]() Page |
![]() |
TRUBOMAT GS3 Turbidity controller ![]()
Created on 30/07/2007 16:51 and updated on 10/04/2018 15:31 |
410-01![]() Starting Up Notice |
![]() |
RXM 2851 Resistive amplifier relay ![]() For highly resistive medium Input adjustable from 4.7 to 100 MΩ Adjustable sensitivity from the front Selectable mode function Function: ON/OFF detection between 2 electrodes Created on 04/08/2008 09:34 and updated on 10/04/2018 14:04 |
533-01![]() Page |
![]() |
CS2.3 Free chlorine sensor, without effect from pH changes ![]() For drinkable water monitoring Range: from 0.01 up to 10 ppm Output signal: 4-20 mA Pressure limit: 0.5 bar as a maximum Unnecessary zero adjustment Created on 27/09/2010 16:15 and updated on 10/04/2018 13:40 |
193-04![]() Page |
![]() |
CC1 Free chlorine sensor, with isocyanuric acid ![]()
Created on 27/12/2010 15:18 and updated on 10/04/2018 15:26 |
193-06![]() Starting Up Notice |
![]() |
VEP K4-PPH Electrically actuated butterfly valves ![]() ND 65 to ND 200 In-line pattern Electric actuator, Position index Manual operating for immediate action Created on 08/12/2011 15:57 and updated on 10/04/2018 14:43 |
914-06![]() Page |