Preview There are 150 results for Relevancy
DKM
Viscosity compensated flow controller, metallic 1E Page (723-01)

• Operates in all positions • Blind controller, 1 contact • Versions: Stainless steel and brass • Pressure up to 350 bar • Viscosity: 30 ... 600 cSt • Flow ranges from 0.5 up to 90 l/min

Created on 17/12/2019 11:59 and updated on 17/12/2019 12:07

723-01

1E

Page
9336
ph and ORP immersion probe 1E Page (130-01)

Electrode holder and protection Easy calibration: buffer flask grips on Flange or PE collar fitting For any KCl gel type electrodes For PG 13.5 electrode threaded connection PVC, PPH or stainless steel construction Wire outlet through a PG 9 •...

Created on 09/10/2006 00:07 and updated on 04/12/2019 10:44

130-01

1E

Page
BSM 501 & BSM 515 English - Deutsch - Castellano
Level switch 1E Starting Up Notice (585-01)

Created on 11/10/2006 17:46 and updated on 10/04/2018 15:49

585-01

1E

Starting Up Notice
BAMOTOP 239
Converter RS 232 / RS 422 - 485 1E Starting Up Notice (239-01)

Created on 22/06/2007 17:46 and updated on 10/04/2018 15:21

239-01

1E

Starting Up Notice
MAXIMAT VK C
Compact overfill sensor 1E Starting Up Notice (555-02)

Created on 28/12/2007 13:59 and updated on 10/04/2018 15:42

555-02

1E

Starting Up Notice
MAXITOP
Compact overfill sensor 1E Starting Up Notice (556-01)

Created on 14/05/2009 14:03 and updated on 10/04/2018 15:44

556-01

1E

Starting Up Notice
NIVOIL 12 V dc
Alarm system for oil-water separators 1E Starting Up Notice (531-02)

Created on 06/05/2010 17:53 and updated on 10/04/2018 15:38

531-02

1E

Starting Up Notice
BAMOPHOX 194
Amperometric sensors signal monitor 1E Starting Up Notice (194-01)

Created on 10/12/2010 09:25 and updated on 10/04/2018 15:27

194-01

1E

Starting Up Notice
VPP K4-PPH
Pneumatically actuated butterfly valves, single / double acting 1E Page (913-06)

ND 65 to ND 200 In-line pattern Pneumatic actuator Single or double acting, Position index Status NC or NO Standard compatibility: NAMUR VDI/VDE 3845 and ISO 5211 OPTIONS Limit switch box Pilot valve

Created on 08/12/2011 10:13 and updated on 10/04/2018 14:40

913-06

1E

Page
VE3V S4-PVDF
Electrically actuated 3-way ball valves 1E Starting Up Notice (914-08)

Created on 28/03/2012 16:57 and updated on 10/04/2018 16:15

914-08

1E

Starting Up Notice
BMG 72
Wall mount galvanometric indicator 1E Page (206-01)

• Wall mount box IP 55 • Dial 72 x 72 • 1 Analogue input • 1 Analogue output 0/4-20 mA • 2 Relay outputs

Created on 10/12/2019 12:52 and updated on 10/12/2019 12:59

206-01

1E

Page
SECURICUVE
LeveL controller 1E Page (584-02)

• Lack of liquid detection (drop of level) • Positive active detection • Compact • Easy to test its integrity on site • Material: Or PPH or PVDF

Created on 11/12/2019 15:08 and updated on 11/12/2019 15:12

584-02

1E

Page
SPEICAL SCALES FOR PDP SERIES
Specific scales for PDP flow indicators 1E Page (731-04)

Created on 17/12/2019 16:11 and updated on 17/12/2019 16:15

731-04

1E

Page
General Catalog
1E Category ()

Created on 23/09/2006 18:41 and updated on 12/04/2018 09:12



1E

Category
DEBIX serie
Flow rate measuring probes 1E Page (760-01)

Suitable for pipes from ND 15 to 3000 mm Low pressure drop Designed for liquids and gases Reliable, accuracy ± 1% Excellent repeatability Fast and economical installation

Created on 09/10/2006 16:36 and updated on 10/04/2018 14:29

760-01

1E

Page
BAMOCHLORE 192
Free chlorine assembly for swimming pools 1E Starting Up Notice (192-01)

Created on 23/04/2007 17:20 and updated on 10/04/2018 15:24

192-01

1E

Starting Up Notice
BRK 60 - BRT 60
Bistable level switch 1E Starting Up Notice (585-02)

Created on 06/08/2007 17:57 and updated on 10/04/2018 15:49

585-02

1E

Starting Up Notice
MAXIMAT TC4
Signaling device 4 sensor inputs 1E Starting Up Notice (555-07)

Created on 22/10/2008 15:57 and updated on 10/04/2018 15:44

555-07

1E

Starting Up Notice
BAMOMATIC
An accurate and tiny little flow rate metre 1E News (news bamomatic)

Since we launched the BAMOMATIC (in 2004), its success is increasing with more than a few thousands of units in use. They are still new applications to discover for this electromagnetic and small metre; the most well known are dosage and flow-rate...

Created on 21/12/2009 16:12 and updated on 10/04/2018 16:26

news bamomatic

1E

News
P9
Peracetic acid sensor 60°C 1E Page (193-32)

CIP disinfection monitoring in Food Industry Range: from 0.001 up to 20.00 g /L Output signal: 0/-2 V With surface-active additives proofed diaphragme Pressure limit: 1 bar as a maximum Unnecessary zero adjustment

Created on 27/09/2010 17:06 and updated on 10/04/2018 13:43

193-32

1E

Page
T 500
Bimetal thermometers 1E Page (696-01)

Case diameter: 100 mm, 125 mm, 150 mm Accuracy: Class 1 (according to EN 13190) Scale ranges: -70...+30°C up to 0...500°C Case and ring: Stainless steel, AISI 304 Bayonet type ring IP65 - EN 60529 /IEC Measuring element: Helicoidal bimetal sensor...

Created on 04/01/2011 17:59 and updated on 10/04/2018 14:26

696-01

1E

Page
VP3V S4-PVC
Pneumatically actuated 3-way ball valves, single / double acting 1E Starting Up Notice (913-02)

Created on 12/12/2011 17:14 and updated on 10/04/2018 16:02

913-02

1E

Starting Up Notice
BAMOPHAR 323
Conductivity 1E Page (323-01)

• Color touch screen • Programmable ranges: From 0-200 Ω .cm up to 0-200 MΩ .cm From 0-2 μS/cm up to 0-20 mS/cm • Associated measuring cells: Cell factors: 10 - 1 - 0.1 - 0.01 • Temperature compensation Automatic or manual compensation • 2...

Created on 10/12/2019 15:19 and updated on 10/12/2019 15:21

323-01

1E

Page
CDP-P
Paddle flow controller 1E Page (710-03)

• For clear liquids • Body in PPO, paddle in polypropylene • For pipes ND 25 up to ND 65 • Mounting: On tee, or on-line with BSP ½'' thread

Created on 17/12/2019 10:23 and updated on 17/12/2019 10:29

710-03

1E

Page
VP2V M1
Pneumatically actuated 2-way ball valves 1E Page (913-21)

• PVC-U or PPH or PVDF valves From ND 10 up to ND 100 • Pneumatic actuator Single or double acting • OPTIONS: Limit switches box Pilot valves

Created on 18/12/2019 11:44 and updated on 18/12/2019 11:50

913-21

1E

Page
TVI & MINITEV
Resistive level probes 1E Page (541-01)

1 up to 4 electrodes Metal - PTFE Process connection: Gas or NPT Head housing: Cast aluminium • For all electrically conductive liquids. • 1 to 4 electrodes • Materials: Metals - PTFE • Pressure: 200 bar Max. • Temperature: 220 °C Max. •...

Created on 10/10/2006 16:34 and updated on 11/12/2019 13:16

541-01

1E

Page
BAMOX 7200
Dissolved oxygen sensor 1E Starting Up Notice (460-02)

Created on 08/06/2007 13:48 and updated on 10/04/2018 15:34

460-02

1E

Starting Up Notice
SFA / E
Gas tight cable operated level indicator 1E Starting Up Notice (583-02)

Created on 01/10/2007 17:23 and updated on 10/04/2018 15:47

583-02

1E

Starting Up Notice
STE
Level control with resistive probes 1E Starting Up Notice (540-01)

Created on 26/12/2008 14:55 and updated on 10/04/2018 15:39

540-01

1E

Starting Up Notice
POLLUTEC 2008
The 23rd International Exhibition 1E News ()

For equipments, technologies and services For environmental matters. Pollutec 2008, 23ème Salon International des équipements, des technologies et des services de l'environnement

Created on 22/12/2009 14:46 and updated on 10/04/2018 16:22



1E

News
CD7
Chlorine dioxide sensor 1E Page (193-11)

- Drinkable water, sea water - Surfactants: partial tolerance - Temperature: 50 °C max. - Pressure: 1 bar max.

Created on 25/11/2010 17:57 and updated on 04/12/2019 16:17

193-11

1E

Page
VE2V S4-PVC
Electrically actuated 2-way PVC ball valves 1E Page (914-01)

ND 10 to ND 100 In-line pattern Electric actuator, Position index Manual operating for immediate action • PVC Valves, from ND 10 up to ND 100 • Radial mounting and dismounting • Electric actuator with position index and manual operating for...

Created on 14/09/2011 09:16 and updated on 18/12/2019 14:41

914-01

1E

Page
VE2V S4-PVC
Electrically actuated 2-way ball valves 1E Starting Up Notice (914-01)

Created on 05/01/2012 17:41 and updated on 10/04/2018 16:06

914-01

1E

Starting Up Notice
9410
On-line holder for pH and ORP electrodes 1E Page (141-02)

• Holder for 1 electrode • For stainless steel piping • Pipe from ND 50 mm • Wet parts: AISI 316 L; FPM • Fitting: Adaptor to weld on pipe

Created on 04/12/2019 11:36 and updated on 04/12/2019 11:40

141-02

1E

Page
NIVOMAG
Magnetic float level switch 1E Page (524-01)

• For level of liquid on any kind of tanks • Versions for neutrals, alkali or acidic fluids • Versions for side or top mounted • Max. 250°C medium temperature • Explosion proof version available

Created on 11/12/2019 11:19 and updated on 11/12/2019 11:30

524-01

1E

Page
DKM/A
Viscosity compensated flow controller/ indicator, metallic 1E Page (723-02)

• Operates in all positions • Indicator, plus 1 adjustable contact • Versions: Stainless steel and brass • Pressure up to 300 bar • Viscosity: 30 ... 600 cSt • Flow ranges from 0.5 up to 90 l/min

Created on 17/12/2019 14:11 and updated on 17/12/2019 14:20

723-02

1E

Page
9346
Immersion probe for pH and ORP measurements 1E Page (135-01)

Electrodes holder and protection  2 or 3 electrodes, thread PG 13.5  PVC or PPH construction  Flange or PE collar fitting  Wire outlet through a cable gland  Easy mounting on site • Electrode holder and protector • Easy calibration routine •...

Created on 09/10/2006 00:16 and updated on 04/12/2019 11:10

135-01

1E

Page
FS4
Top mounting level indicator 1E Starting Up Notice (584-01)

Created on 11/10/2006 17:50 and updated on 10/04/2018 15:48

584-01

1E

Starting Up Notice
8306
Probe holder poles 1E Page (143-01)

• For immersion probes 9336, 9337 or 9346 • Totally modular • Protecting roof for monitor • Rotation on 360° • Translation on both axes • Stainless steel and aluminium

Created on 26/06/2007 13:51 and updated on 04/12/2019 11:54

143-01

1E

Page
MAXIMAT LW CN-SDR
Leakage detection transmitter 1E Starting Up Notice (555-04)

Created on 28/12/2007 15:31 and updated on 10/04/2018 15:43

555-04

1E

Starting Up Notice
SPM 903
Plastic gauge guards 1E Page (903-02)

The pressure gauge guards SPM 903, are suitable to protect the pressure sensors against the destroying effects of aggressive fluids Upper cover: PPG, glass fibre reinforced Polypropylene Base plate: PVC-U, PP, PVDF Diaphragm: EPDM, PTFE coated Process...

Created on 08/09/2009 18:20 and updated on 18/12/2019 10:22

903-02

1E

Page
BAMOBOX BBS
Autonomous system for oil-water separators 1E Starting Up Notice (531-03)

Created on 06/05/2010 17:57 and updated on 10/04/2018 15:38

531-03

1E

Starting Up Notice
MW Line
Pocket photometers for chlorine 1E Page (190-11)

Easy to use: 1 touch button Free chlorine (MW10) or total chlorine (MW11) For Drinkable water and swimming pool water Range: 0.05 to 2.5 ppm Ready to use for DPD tests Battery powered

Created on 15/12/2010 08:46 and updated on 10/04/2018 13:38

190-11

1E

Page
VP2V S4-PVDF
Pneumatically actuated 2-way ball valves, single / double acting 1E Page (913-07)

ND 10 to ND 100 In-line pattern Pneumatic actuator Single or double acting, Position index Status NC or NO Standard compatibility: NAMUR VDI/VDE 3845 and ISO 5211  OPTIONS Limit switch box Pilot valve

Created on 08/12/2011 14:15 and updated on 10/04/2018 14:40

913-07

1E

Page
VEP K4-PVDF
Electrically actuated butterfly valves 1E Starting Up Notice (914-09)

Created on 28/03/2012 17:07 and updated on 10/04/2018 16:16

914-09

1E

Starting Up Notice
NANODAC
Recorder - Digital and Graphic indicator 1E Page (212-02)

• 3.5'' TFT color display, 320x240 resolution • 4 Inputs: TC, RTD, mA, mV and V • 1 Logic data input / output • 2 potential free contact Inputs • 4 Relay outputs • 14 Virtual channels: Calculations, totalisers, counters ... • Modbus Slave...

Created on 10/12/2019 13:02 and updated on 10/12/2019 13:06

212-02

1E

Page
NIVAPRESS SGE-25
Hydrostatic level transmitter 1E Page (590-03)

• Measuring ranges up to 500 m H₂O • Probe: AISI 316 L • Diaphragm: Hastelloy • Protection against overloads • ATEX or DNV certification

Created on 11/12/2019 15:51 and updated on 11/12/2019 15:53

590-03

1E

Page
BAMOFLONIC - PFA
Ultrasonic flow-meter 1E Page (776-02)

• 4 models ND 7 to ND 20 • Measuring ranges from 0.09 up to 120 l/min • Wet parts in PFA; Casing in PP • 1 Analogue output 0/4-20 mA • 1 Digital output, to set up

Created on 17/12/2019 16:45 and updated on 17/12/2019 16:52

776-02

1E

Page
DB Series
Orifice plate, flow-meters 1E Page (765-01)

• For agressive liquids • Direct reading indicator on pipes from ND 50 up to 200 • Mounting in all positions • According standard NF X 10-102 • Options: Flow contact; Output signal

Created on 09/10/2006 16:55 and updated on 17/12/2019 16:35

765-01

1E

Page
BAMOPHOX 192
Free Chlorine monitoring with Open cell amperometric method 1E Starting Up Notice (192-02)

Created on 26/04/2007 11:12 and updated on 10/04/2018 15:24

192-02

1E

Starting Up Notice
9240
pH or ORP in-line electrode holder 1E Starting Up Notice (140-02)

Created on 07/08/2007 17:16 and updated on 10/04/2018 15:18

140-02

1E

Starting Up Notice
LISA
Leakage detection: Liquid Intrusion Safety Alarm 1E Page (544-03)

LISA system or “ Liquid Intrusion Safe Alarming”, is designed for alarming as soon as humidity or a drop of water is detected on a ribbon like sensor. The fail safe alarming system LISA includes, as a minimum, one ribbon sensor or one-point...

Created on 23/10/2008 10:25 and updated on 11/12/2019 13:28

544-03

1E

Page
BAMO implements its WEB site
New appearance and dynamic show room for a better understanding 1E News ()

Beginning of 2003, BAMO implements its WEB site with the version 2 of CARIBASE, newest software from CARIMEDIA. End of 2004, we wish a dynamic interface with our visitors: it is done with the last version 3! On time up-dates and easy downloads are the...

Created on 21/12/2009 16:30 and updated on 10/04/2018 16:25



1E

News
MEASURING CELLS
Amperometric sensors 1E Page (193-95)

For sanitary, drinkable, cooling, water processed Dedicated holder for up to 5 sensors: Amperometric sensors, pH and ORP electrodes Flow limit controller, flow rate adjustment Stainless steel pin as liquid reference potential Outlet valve for sampling...

Created on 27/09/2010 17:11 and updated on 04/12/2019 17:19

193-95

1E

Page
ITU 404 - ITU 414
Panel mounting indicators 1E Page (222-04)

• Versatile display indicator, programmable • Inputs: mA, V, Pt 100, Ni 100, TC, Potentiometric input • Power supply: 21.6 to 253 V AC 50/60 Hz and 19.2 to 300 V DC • 4 digits display / LED 14 segments • Power supply to sensor: 15 to 25 V DC /...

Created on 19/01/2011 13:42 and updated on 10/12/2019 13:25

222-04

1E

Page
VPP K4-PVC
Pneumatically actuated butterfly valves, single / double acting 1E Starting Up Notice (913-03)

Created on 12/12/2011 17:27 and updated on 10/04/2018 16:02

913-03

1E

Starting Up Notice
BAMOPHAR 364
Conductivity meter for inductive probe 1E Page (364-04)

• Color touch screen • Measuring range, 4 scales: 0- 2 mS/cm up to 0 - 2000 mS/cm • Automatic temperature compensation • 2 Outputs 0/4-20mA • 4 Relays (Thresholds, alarm and/or regulation) • OPTIONS : RS 422 /J-BUS + LOGGER Extension...

Created on 10/12/2019 15:38 and updated on 10/12/2019 15:40

364-04

1E

Page
CDSP 25
Adjustable paddle flow controller 1E Page (712-01)

• For clear liquids • On-line mounting; ND 25 to ND 200 • Stainless steel or brass versions • Up to 11 bar: brass; Up to 30 bar: AISI 316 • Adjustable trigger point • Liquid temperature: -40 ... +120 °C • Ambient temperature: Max. 85 °C...

Created on 17/12/2019 10:31 and updated on 17/12/2019 10:36

712-01

1E

Page
EV160
PILOT OPERATED SOLENOID VALVES 1E Page (920-01)

• PVC or PP, female fittings from ND 15 up to ND 50 PTFE, BSPF from ½'' up to 2'' • Pilot operated, with the liquid pressure • Pressure from 0.3 to 6 bar • 2-way valves • Diaphragm EPDM or FPM

Created on 18/12/2019 15:26 and updated on 18/12/2019 15:34

920-01

1E

Page
HE / HS
Cable suspended resistive level probes 1E Page (542-01)

2 types: for aggressive or neutral fluids Materials: Stainless steel, 1.4571 Carbon-glass For electrically conductive liquids Detection height up to 25 m 2 types: for aggressive or neutral fluids

Created on 10/10/2006 16:40 and updated on 10/04/2018 14:06

542-01

1E

Page
BNC
Resistivity and conductivity 1E Starting Up Notice (360-01)

Created on 11/06/2007 18:33 and updated on 10/04/2018 15:30

360-01

1E

Starting Up Notice
T2FR 5333
Programmable 2 wires transmitter 1E Page (601-05)

PT100 ohm and resistance input Programmable by computeur 4/20mA or 20/4 mA SI EEx ia IIC, T1 -T6 in option

Created on 20/12/2007 09:30 and updated on 10/04/2018 14:23

601-05

1E

Page
B E S
Floor leakage monitoring 1E Page (540-02)

Floor water detection Entirely static Conductive sensor, stainless steel electrodes Cable output, 5 m long Built-in device for detection loop monitoring

Created on 26/01/2009 13:55 and updated on 10/04/2018 14:05

540-02

1E

Page
LISA
Water traces and leakage detector 1E News ()

LISA will detect immediately the presence of unexpected water in systems and buildings 1 drop of water is sufficient for alarming and sending you the information. The signal alarm occurs before the flood affects the monitored area. A self-test of the...

Created on 22/12/2009 14:50 and updated on 10/04/2018 16:21



1E

News
CCK
Chlorine dioxide and free chlorine sensor 1E Page (193-12)

Opened cell, 3 electrodes For industrial hot water, drinkable water, cooling water Range: 0.01 to 4 ppm Output signal: 4-20 mA Pressure limit: 6 bar Temperature limit: 5...70 °C With automatic cleaning system For industrial hot water, drinkable...

Created on 25/11/2010 18:05 and updated on 10/04/2018 13:41

193-12

1E

Page
VE3V S4-PVC
Electrically actuated 3-way ball valves 1E Page (914-02)

• PVC ball valves ND 10 to ND 50 • In-line pattern • Electric actuator, position index, manual emergency action

Created on 14/09/2011 09:31 and updated on 18/12/2019 14:50

914-02

1E

Page
VM2V S4
Manually operated 2-way ball valves 1E Page (934-02)

Secured handle, lockable In-line pattern 100% free way Secured handle, lockable In-line pattern 100% free way

Created on 12/01/2012 18:00 and updated on 10/04/2018 14:45

934-02

1E

Page
2000 series
Combined pH electrodes without liquid junction 1E Page (150-03)

• High chemical resistance • Pressure limit: up to 20 bar • Long lifetime • Without liquid bridge • No KCl leaking

Created on 04/12/2019 12:19 and updated on 04/12/2019 12:27

150-03

1E

Page
VAFLO
Level controller with stop valve 1E Page (527-01)

• Self-sufficient system • Level controller • Adjustable height • Float in Polyester or in PPH

Created on 11/12/2019 11:32 and updated on 11/12/2019 12:45

527-01

1E

Page
DKG
Viscosity compensated flow controller/ indicator 1E Page (724-01)

• Operates in all positions • Indicator, plus 1 adjustable contact • Stainless steel and brass versions • Pressure up to 16 bar • Viscosity: 30 ... 600 cSt • Flow ranges from 0.1 up to 90 l/min

Created on 17/12/2019 14:21 and updated on 17/12/2019 14:31

724-01

1E

Page
9360
Auto-cleaning probe 1E Page (145-01)

• Chemical and mechanical cleaning • For one pH electrode PG 13.5 • Easy to install • Accessory added to the pH probe

Created on 09/10/2006 10:14 and updated on 04/12/2019 11:58

145-01

1E

Page
BAMOBUL
Air bubbling level transmitter 1E Starting Up Notice (758-02)

Created on 11/10/2006 17:53 and updated on 10/04/2018 15:55

758-02

1E

Starting Up Notice
STS
Resistive level probes 1E Page (543-01)

For aggressive and electrically conductive liquids Construction: PVC or PVDF Manufacture on request upon drawings Fixed alarm distances 4 contacts as a maximum

Created on 20/03/2007 18:43 and updated on 10/04/2018 14:07

543-01

1E

Page
TURBISENS
Turbidity transmitter, Immersion Probe 1E Page (443-01)

Compact transmitter 4-20 mA High resolution from 0.01 FNU Integrated 4 digits display for: Actual value Programming Settings Compact transmitter 4-20 mA Measurement according to ISO 7027, infrared light source 860 nm Selectable Ranges in FNU 0...50...

Created on 26/06/2007 15:20 and updated on 10/04/2018 13:57

443-01

1E

Page
NIVOSTOP® - SG2
Level controller 1E Page (520-03)

Built in ballast Potential-free micro-switch High switching rating Quick and easy to install PVC or TPK cables, length 5 m, 10 m ... Built in ballast Potential-free micro-switch High switching rating Quick and easy to install PVC or TPK cables, length 5...

Created on 19/02/2008 18:00 and updated on 10/04/2018 14:01

520-03

1E

Page
DOSAControl DCW 100
Monitor for CCK sensors 1E Page (194-05)

AUTO-CLEANING SENSOR by reverse polarity LCD back lighted display, friendly using menu 1 specific input for CCK sensor 1 analog output 0/4-20 mA Automatic temperature compensation 2 relays for ON/OFF and PID regulation Pulse output for ON-OFF, PID...

Created on 15/12/2010 11:51 and updated on 10/04/2018 13:44

194-05

1E

Page
VP3V S4-PVDF
Pneumatically actuated 3-way ball valves, single / double acting 1E Page (913-08)

ND 10 to ND 50 In-line pattern Pneumatic actuator Single or double acting, Position index Status NC or NO

Created on 08/12/2011 14:24 and updated on 10/04/2018 14:40

913-08

1E

Page
BAMOPHAR 216
Monitor - Recorder 1E Page (216-02)

- Color touch screen - 1 Sensor input, 0/4-20 mA Display without or with measuring unit: m; cm; %; ppm; mg; g; °C; _ (none) - 1 Pt100 sensor input - 2 Outputs 0/4-20 mA (measurement & T °C) - 4 Relay outputs (thresholds, alarm and/or regulation)...

Created on 10/12/2019 13:08 and updated on 10/12/2019 13:11

216-02

1E

Page
INTERNIV 590
Electronic gauge for diesel 1E Page (590-06)

- For storage tanks of diesel (fuel oils) - Measuring ranges: Up to 3 m - Output signal: 4-20 mA, power 8 ... 32 V DC - Compact, robust probe (stainless steel) - PVC cable compatible with diesel

Created on 11/12/2019 15:57 and updated on 11/12/2019 15:58

590-06

1E

Page
BAMOFLONIC 42i
Ultrasonic flow-meter 1E Page (776-04)

• For liquids electrically conductive or not • Ranges from 0.024 up to to 60 l/min • Wet parts all in PE-HD • 1 Analogue output 0/4-20 mA • 1 Digital output (various functions)

Created on 17/12/2019 16:54 and updated on 17/12/2019 17:00

776-04

1E

Page
BAMO France
BAMO Mesures 1E ()

Fabricant français de capteurs et d'instruments pour contrôle et analyse des fluides

Created on 30/03/2012 17:18 and updated on 30/03/2012 17:20



1E

News
1E Category ()

General Information/

Created on 23/09/2006 18:33 and updated on 27/03/2018 15:42



1E

Category
Workshops Head Office
1E Page ()

Our Facilities BAMO Mesures SAS in Argenteuil: we opened our new building in July 11, 2005  West front, main entrance It is an efficient building for manufacturing, with Stores, Commercial and Development facilities. The Head office is able to afford a...

Created on 01/04/2012 11:17 and updated on 10/04/2018 16:26



1E

Page
pH and ORP
100 1E Category (100)

User Manuals/

Created on 28/09/2006 22:53 and updated on 03/04/2018 11:21

100

1E

Category
pH and ORP
100 1E Category (100)

General Catalog/

Created on 23/09/2006 18:42 and updated on 03/04/2018 11:27

100

1E

Category
Chlorine, disinfection
190 1E Category (190)

General Catalog/

Created on 12/10/2010 18:54 and updated on 03/04/2018 11:28

190

1E

Category
Chlorine, disinfection
190 1E Category (190)

User Manuals/

Created on 12/10/2010 19:00 and updated on 03/04/2018 11:21

190

1E

Category
Data processors
200 1E Category (200)

General Catalog/

Created on 23/09/2006 18:43 and updated on 03/04/2018 11:28

200

1E

Category
R&D
For Your Safety 1E Page ()

Product development is conducted in accordance with DIN EN ISO 9001:2000 procedures, as well as all applicable legal requirements and European standards. Testing in our own EMC lab, as well as by external approval authorities (i.e. TÜV, BIBt etc.),...

Created on 10/10/2006 19:07 and updated on 10/04/2018 16:27



1E

Page
BAMO Deutschland
BAMO IER 1E ()

Innovative Messtechnik für Füllstand, Trübung und Analyse in Flüssigkeiten

Created on 30/03/2012 17:22 and updated on 19/11/2013 16:07



1E

About us
1E Category ()

General Information/

Created on 23/09/2006 18:39 and updated on 27/03/2018 15:44



1E

Category
Data processors
200 1E Category (200)

User Manuals/

Created on 28/09/2006 22:54 and updated on 03/04/2018 11:22

200

1E

Category
BAMO Portugal
GLOBALÁGUA, LDA 1E ()

Instrumentação e Controlo de Águas

Created on 02/02/2016 10:12 and updated on 02/02/2016 10:13



1E

Contact Us
1E Category ()

You can contact us Via: E-mail:   Phone:   Fax:   Post: Link to:  General Information/

Created on 04/04/2012 20:35 and updated on 27/03/2018 15:49



1E

Category
Conductivity
300 1E Category (300)

General Catalog/

Created on 23/09/2006 18:44 and updated on 03/04/2018 11:29

300

1E

Category
Manufacturing and assembly
1E Page ()

All of the necessary technologies are at our disposal - in house. This guarantees us the flexibility we need to produce custom devices for you in the shortest time. Well trained employees, as well as documented procedures and work directives wich have...

Created on 10/10/2006 19:10 and updated on 10/04/2018 16:27



1E

Page
Conductivity
300 1E Category (300)

User Manuals/

Created on 28/09/2006 22:54 and updated on 03/04/2018 11:22

300

1E

Category
BAMO International
1E Category ()

General Information/

Created on 29/03/2012 09:42 and updated on 27/03/2018 15:50



1E

Category
Water hardness
375 1E Category (375)

General Catalog/

Created on 12/10/2010 18:57 and updated on 03/04/2018 11:29

375

1E

Category
Turbidity
400 1E Category (400)

User Manuals/

Created on 06/11/2006 15:33 and updated on 03/04/2018 11:23

400

1E

Category
BAMO Polska
BAMO Polska Sp. z o.o. 1E ()

Europejski producent czujników oraz urządzeń do kontroli i analizy cieczy

Created on 10/09/2014 14:59 and updated on 24/09/2019 14:46



1E

Testing
1E Page ()

All electrical devices are subjected to strict, individual testing. Adherence to documented inspection procedures assures flawless functioning of all subassemblies and components during production, as well as after final assembly. Additional testing...

Created on 10/10/2006 19:12 and updated on 10/04/2018 16:30



1E

Page
BAMO España
GlobalAgua España 1E ()

Fabricante europeo de sensores e instrumentos para líquidos

Created on 30/03/2012 17:29 and updated on 24/10/2013 11:30



1E

Turbidity
400 1E Category (400)

General Catalog/

Created on 11/10/2006 17:33 and updated on 03/04/2018 11:29

400

1E

Category
Oxygen
450 1E Category (450)

User Manuals/

Created on 28/09/2006 22:55 and updated on 03/04/2018 11:23

450

1E

Category
Oxygen
450 1E Category (450)

General Catalog/

Created on 23/09/2006 18:46 and updated on 03/04/2018 11:30

450

1E

Category
Level
500 1E Category (500)

User Manuals/

Created on 28/09/2006 22:55 and updated on 03/04/2018 11:24

500

1E

Category
Level
500 1E Category (500)

General Catalog/

Created on 23/09/2006 18:46 and updated on 03/04/2018 11:31

500

1E

Category
BAMO International
BAMO Mesures 1E ()

European manufacturer of sensors and instruments for liquids

Created on 30/03/2012 17:25 and updated on 30/03/2012 17:26



1E

Company History
1E Page ()

BAMO MESURES SAS has been founded in 1978. Its capital is now 400 000 Euros. Since the beginning, the company has undergone a rapid development centring on industrial pH-meters and conductivity meters. BAMO is now well-known as a leader on the French...

Created on 01/04/2012 11:08 and updated on 01/04/2012 11:31



1E

Page
Temperature
600 1E Category (600)

General Catalog/

Created on 23/09/2006 18:47 and updated on 03/04/2018 11:31

600

1E

Category
Flow
700 1E Category (700)

User Manuals/

Created on 28/09/2006 22:56 and updated on 03/04/2018 11:24

700

1E

Category
Terms and Conditions of Sales
Foreign Countries 1E Page ()

Terms and conditions   Unless otherwise stipulated in our offer or documentation, the terms and conditions of sale   hereinafter apply to all services and products we commercialize. 

Created on 27/06/2011 17:18 and updated on 01/04/2012 11:35



1E

Page
Flow
700 1E Category (700)

General Catalog/

Created on 23/09/2006 18:47 and updated on 03/04/2018 11:32

700

1E

Category
Pressure
800 1E Category (800)

General Catalog/

Created on 15/09/2009 18:58 and updated on 03/04/2018 11:32

800

1E

Category
Pressure
800 1E Category (800)

User Manuals/

Created on 15/09/2009 18:56 and updated on 03/04/2018 11:25

800

1E

Category
Plastic Valves
900 1E Category (900)

User Manuals/

Created on 12/10/2010 19:11 and updated on 03/04/2018 11:25

900

1E

Category
Plastic Valves
900 1E Category (900)

General Catalog/

Created on 23/09/2006 18:48 and updated on 03/04/2018 11:32

900

1E

Category
pH and ORP
1E Category (100)

Archives/

Created on 18/12/2019 17:22 and updated on 18/12/2019 17:23

100

1E

Category
Chlorine, Disinfection
1E Category (190)

Archives/

Created on 17/12/2019 17:02 and updated on 17/12/2019 17:03

190

1E

Category
Data processors
200 1E Category (200)

Archives/

Created on 01/04/2012 15:07 and updated on 03/04/2018 11:26

200

1E

Category
Water hardness
375 1E Category ()

Archives/

Created on 04/02/2022 12:12 and updated on 04/02/2022 12:13



1E

Category
Turbidity
1E Category ()

Archives/

Created on 04/02/2022 12:16 and updated on 04/02/2022 12:16



1E

Category
Oxygen
1E Category ()

Archives/

Created on 04/02/2022 12:21 and updated on 04/02/2022 12:21



1E

Category
Level
500 1E Category (500)

Archives/

Created on 01/04/2012 15:14 and updated on 03/04/2018 11:26

500

1E

Category
NIVOSTOP® - SS2 / HYP
Level controller, all in Hypalon 1E Page (520-02)

Compatibility with basic, leak acid solutions and other aggressive chemicals Restrictions: due to the cable made of HYPALON and additives Adjustable ballast Maximal pressure 5.5 bar Maximal temperature 95°C

Created on 26/11/2009 12:44 and updated on 10/04/2018 16:32

520-02

1E

Page
Flow
700 1E Category (700)

Archives/

Created on 01/04/2012 15:15 and updated on 03/04/2018 11:27

700

1E

Category
9500
In-line electrode holders under pressure 1E Page (142-01)

• pH or ORP measurement • Construction: AISI 316 L • Pressure max. 16 bar • Temperature max. 110 °C • Fittings PG13.5 or BSP 1/2'' • For electrodes with fitting PG 13.5 • Process connections ND 15 to 32 mm

Created on 08/02/2007 16:03 and updated on 04/12/2019 11:46

142-01

1E

Page
BAMOPHOX 192
Free Chlorine monitoring with Open cell amperometric method 1E Page (192-02)

Alphanumeric back lighted LCD display Friendly using menu Ranges  from 0 to 5 mg/l for free chlorine -20...+160°C for temperature 2 analogical outputs 0/4-20mA, galvanic insulated  3 relay outputs (Normally Open contacts) 1 relay output for system...

Created on 03/01/2007 11:10 and updated on 10/04/2018 13:38

192-02

1E

Page
GA 1 – GA 2 – GA 11 – GA 5
Armatures for turbidity control 1E Page (421-01)

Sensor fixture with emitter and receiver To use with the turbidity controller TRUBOMAT GS3 DN 15 to DN 200 In-line mounting or as a by-pass Construction PVC, PPH, Stainless steel Sensor fixture with emitter and receiver To use with the turbidity...

Created on 21/02/2007 17:24 and updated on 10/04/2018 13:55

421-01

1E

Page
MUDLine® TGS
Portable sludge level measuring instrument 1E Page (426-01)

Battery powered Mud level detection in primary and secondary clarifier, thickener and other applications Useful also in rotten black sludge Sludge level monitoring in small sewage plants Immersion depth: 10 m as a maximum Field portable device Sludge...

Created on 03/11/2006 11:22 and updated on 10/04/2018 13:56

426-01

1E

Page
MUDLine® TGS
Portable sludge level measuring instrument 1E Starting Up Notice (426-01)

Created on 03/11/2006 11:28 and updated on 10/04/2018 15:31

426-01

1E

Starting Up Notice
BAMOPHOX 106
pH-Meter and mV-Meter 1E Starting Up Notice (106-01)

Created on 16/02/2007 10:37 and updated on 10/04/2018 14:50

106-01

1E

Starting Up Notice
9090
Temperature compensation probe 1E Page (150-02)

• For mounting on holders 9200, 9500 et 9346 • Sensor Pt 100 Ω at 0 °C • Versions: Simplex or Duplex • Fitting PG 13.5

Created on 26/02/2007 10:23 and updated on 04/12/2019 12:18

150-02

1E

Page
pH and ORP ACCESSORIES
Accessories 1E Page (160-01)

Created on 26/02/2007 11:32 and updated on 04/12/2019 13:57

160-01

1E

Page
BAMOTOP 281
Frequency converter 1E Page (281-01)

• For any pulse emitter such as: BAMOFLU, BAMOTUR, Micro-stream, FFG, DF 140, Counters M, BAMOMATIC (12 V) • Input modes to configure • Range: 1 ... 25000 Hz • Galvanic insulated output • Current: 0/4-20 mA or 0-5/10 V • Response time to set...

Created on 16/05/2007 10:16 and updated on 10/12/2019 14:22

281-01

1E

Page
BAMOPHOX 319 ML-DB
Resistivity Metre 1E Page (319-02)

2 independent sensors Input 1: range 0...20 MΩ Input 2: scalable range 0...20 MΩ / 0...2 MΩ Dedicated probes and sensors With Factor probe C = 0.01, 0.1, 1 and 10 2 adjustable analog output 0/4-20 mA 3 relay outputs (NO contact) Wall mounting IP 65

Created on 28/02/2007 09:33 and updated on 10/04/2018 13:51

319-02

1E

Page
BAMOPHOX 322
Resistivity / Conductivity 1E Page (322-01)

Monitor and controller MΩ - mS Programmable scales: 0...200 Ω up to 0...20 MΩ 0...2 μS up to 0...20 mS TOR version, 0...2 mS up to 0...2000 mS Convenient probes: With cell contant, 10 ; 1 ; 0.1 ; 0.01 or with TOR sensor Automatic or manual...

Created on 09/10/2006 11:09 and updated on 10/04/2018 13:52

322-01

1E

Page
TCS 3020 Series
Inductive conductivity probe in NORYL 1E Page (364-01)

Process measurement  on line  or by immersion For waste liquids Wide range of applications  Large scales: from 0-2 to 0-2000 mS Probe material: NORYL • Range: from 10 μS/cm up to 2000 mS/cm • Material: NORYL • Temperature max. 105 °C • Low...

Created on 28/02/2007 10:35 and updated on 10/12/2019 15:36

364-01

1E

Page
TRUBOMAT GS 3
Turbidity controller 1E Page (410-01)

ON/OFF turbidity Controller  No effect of day light  Output relay  Adjustable delay  Dysfunction indicator

Created on 22/02/2007 18:05 and updated on 04/02/2022 12:17

410-01

1E

Page
BAMOPHOX 436
Turbidity monitor 1E Page (436-01)

Alphanumeric back lighted LCD display 2 models available: Panel mounting 72 x 144 (436E) Wall mounting IP 65 (436M) 3 relay outputs (Normally Open contacts) 1 relay output for system alarm 2 analogical outputs 0/4-20mA Scales NTU, FAU, mg/L, g/L, FNU ...

Created on 15/02/2007 11:26 and updated on 04/02/2022 12:18

436-01

1E

Page
TURBICUBE
In line turbidity transmitter 1E Page (444-01)

Drinking water plants Raw and waste water Phase separation, filtration Measuring range: 0.01...1000 FNU Output signal: 0/4-20 mA Immediate connection to BAMOPHOX monitor, data logger and regulator Flow-through in-line turbidimeter acc. ISO 7027...

Created on 15/02/2007 11:05 and updated on 10/04/2018 13:57

444-01

1E

Page
MNR 7
Magnetic float level controller 1E Page (550-01)

Available in PVC – PPH - PVDF Up to 4 bi-stable change over contacts High switch power capacity Independent from density. Foam or vapors do not interfere Option for a continuous measurement Specific documentation: 586 = RTM/MNR7 Available in PVC –...

Created on 26/02/2007 11:15 and updated on 10/04/2018 14:09

550-01

1E

Page
MNR 7 - 316L
Stainless steel magnetic float level controller 1E Page (550-02)

Construction: stainless steel 316 Up to 4 bi-stable change over contacts High switch power capacity Independent from density. Foam or vapors do not interfere Option for a continuous measurement, see our specific documentation 586 about RTM/MNR7

Created on 26/02/2007 10:58 and updated on 10/04/2018 14:09

550-02

1E

Page
MNR 7 Ex
Magnetic float level controller 1E Page (550-03)

Construction: stainless steel 1.4571 (316 Ti – AISI)  Up to 4 bi-stable change over contacts ATEX II 1/2 G - EEx ib IIC T4 Construction: stainless steel 1.4571 (316 Ti – AISI)  Up to 4 bi-stable change over contacts ATEX II 1/2 G - EEx ib IIC T4

Created on 26/02/2007 10:47 and updated on 10/04/2018 14:10

550-03

1E

Page
MAXIMAT LW CN-SDR
Leakage detection transmitter 1E Page (555-04)

Capacitive, high frequency, fail-safe detection  For aggressive and conductive liquids  Two sensors Positive active alarm  Auto diagnostic system and LED indicator  WHG §19, approval DIBt-No.: Z-65.40-316

Created on 13/02/2007 15:13 and updated on 10/04/2018 14:11

555-04

1E

Page
MAXIMAT LWC-B
Leakage detection sensor 1E Page (555-05)

Floor standing leakage detector  Capacitive, high frequency, fail-safe detection  For aggressive and electrically conductive liquids  Positive active alarm  Auto diagnostic system and LED indicator

Created on 13/02/2007 15:47 and updated on 10/04/2018 14:12

555-05

1E

Page
MAXIMAT SHR CS
Measuring transducer 1E Page (555-06)

Alarm signal relay for leakage or overfill transmitters Designed for overfill and leakage sensors  MAXIMAT®C,  MAXIMAT®VK..,  MAXIMAT®LW..,  CAPSYTRON SFL  DIBT Approval Designed for overfill and leakage sensors  MAXIMAT®C, ...

Created on 13/02/2007 16:05 and updated on 10/04/2018 14:12

555-06

1E

Page
MAXIMAT TC4
Signaling device 4 sensor inputs 1E Page (555-07)

4 surveying channels for leakage or overfill transmitters 4 surveying channels  For compact overfill or leakage sensors  MAXIMAT® C, MAXIMAT® VK..., MAXIMAT® LW... Microprocessor controlled Automatic sensor detection and survey  Sensors and...

Created on 26/02/2007 11:22 and updated on 10/04/2018 14:12

555-07

1E

Page
MAXIMAT LW VK
Leakage detection sensor 1E Page (555-08)

Float level fail-safe detection  For aggressive and non electrically conductive liquids  Positive active alarm  Auto diagnostic system and LED indication when in use with a SHR C transducer  Approvals: DIBT Z-65.40-272, for leakage detection,...

Created on 13/02/2007 17:48 and updated on 10/04/2018 14:13

555-08

1E

Page

« 1 2 3 »

Technical & Commercial support's main contacts
Ask a QUOTATION online
BAMO Mesures SAS
22 Rue de la Voie des Bans
Parc d'activités de la Gare
95100 ARGENTEUIL France
Tel : +33 (0)130 258 332
Fax : +33 (0)134 101 605

Email : info@bamo.fr
Company n° 314 055 864
SIC : 2651 B

URL : http://www.bamocontrol.co.uk
Designed and hosted by CARIMEDIA since 1998
© 1998-2025 All rights reserved - Disclaimer