Preview | There are 150 results for | Relevancy |
BV 91 - BV 95 Vent valves Page (949-02) • Air inlet and outlet controls • Body: PVC, PP or PVDF • From ND 10 up to ND 80 • BV 91 free ball valve, for tank ventilation • BV 95 ball valve, spring assistance, for tank ventilation & vacuum breaking Created on 18/12/2019 16:21 and updated on 18/12/2019 16:25 |
949-02 Page |
9200 In-line holders for 1 to 3 electrodes, pH or ORP Page (140-01) pH or ORP continuous flow cells For 1 to 3 electrodes pH, mV PVC or PPH material Various process connections available • Holder for 1, 2 or 3 electrodes • Construction: PVC or PPH • Process fitting: Union ND 20, diam. 25 mm Created on 05/10/2006 17:31 and updated on 04/12/2019 11:17 |
140-01 Page |
9423 In-line probe electrode holder Starting Up Notice (141-01)
Created on 15/06/2007 17:26 and updated on 10/04/2018 15:18 |
141-01 Starting Up Notice |
TS 16 Temperature sensor Page (616-01) Pt 100 Ω at 0 °C Measurement range -200 ...+600 °C Stainless steel stem Waterproof cable output Created on 20/12/2007 14:29 and updated on 10/04/2018 14:25 |
616-01 Page |
MAXITOP Compact overfill sensor Page (556-01) Universal use for electrically conductive, non-flammable water endangering liquids According WHG § 19 in Germany, the series is called MAXIMAT® C. No moving parts Process connection BSP 2", PVC, sliding Stem PEHD: Ø 40 mm Adjustable immersion... Created on 25/03/2009 14:56 and updated on 10/04/2018 14:15 |
556-01 Page |
MAXITOP LWC Leakage detection probe Page (556-03) Leakage sensor Universal use for electrically conductive, non-flammable water endangering liquids According WHG § 19 in Germany, the series is called MAXIMAT® LW-C. Stem: PEHD, Ø 40 mm (Ø 25 on request) With fastening angle and adjustable... Created on 10/03/2010 15:12 and updated on 10/04/2018 14:15 |
556-03 Page |
Pooltest 3 Photometer for chlorine and isocyanuric acid Page (190-10) • For swimming pools • Measuring ranges Chlorine from 0.01 to 5 & 10 mg/l Isocyanuric acid from 2 to 200 mg/l pH from 6.5 to 8.4 • Delivered ready to use Created on 06/12/2010 15:06 and updated on 04/12/2019 14:19 |
190-10 Page |
VP3V S4-PVC Pneumatic 3-way ball valves single or double acting Page (913-02) ND 10 to ND 50 In-line pattern Pneumatic actuator Single or double acting Position index Status NC or NO • PVC Valves from ND 10 up to ND 50 • Pneumatic actuator Single or double acting • Position pointer • Options: Limit switches box Pilot... Created on 07/12/2011 11:38 and updated on 18/12/2019 11:21 |
913-02 Page |
VE2V S4-PPH Electrically actuated 2-way ball valves Starting Up Notice (914-04)
Created on 28/03/2012 16:42 and updated on 10/04/2018 16:08 |
914-04 Starting Up Notice |
OZ7 Ozone sensor Page (193-21) - Drinkable water, sea water - Surfactants: partial tolerance - Temperature: 45 °C max. - Pressure: 1 bar max. Created on 04/12/2019 16:33 and updated on 04/12/2019 16:44 |
193-21 Page |
JEPA 580 Level gauge Electro-pneumatic, autonomous Page (580-02) • For compatible liquids (diesel, water, ...) • Displays in cm or Volume • For any kind of tanks • Battery operated • Height max.: Diesel 3 m; Water 2.5 m Created on 11/12/2019 14:06 and updated on 11/12/2019 14:08 |
580-02 Page |
IDP Plastic flow indicator Page (730-05) • Direct reading • All wet parts in plastics • Measuring tubes: PVC or Polysulfone • Ranges: Up to 60 m³/h Specific scales for Air, HCl, NaOH, etc. • Options: Adjustable contacts, ruler with 4-20 mA transmitter Created on 17/12/2019 15:24 and updated on 17/12/2019 15:35 |
730-05 Page |
RTM Continuous level transmitter Page (586-01) Signal output: 4-20 mA Step: 10 mm The RTM is adapted to our level indicators MAGTOP, SFA, MNR 6 and MNR 7. Continuous level transmitter Output 4-20 mA or Ohm Accuracy: 10 mm Direct mounting above the tank Available for MAGTOP and SFA Created on 27/03/2007 14:20 and updated on 10/04/2018 14:20 |
586-01 Page |
TRUBOMAT GS3 Turbidity controller Starting Up Notice (410-01)
Created on 30/07/2007 16:51 and updated on 10/04/2018 15:31 |
410-01 Starting Up Notice |
RXM 2851 Resistive amplifier relay Page (533-01) For highly resistive medium Input adjustable from 4.7 to 100 MΩ Adjustable sensitivity from the front Selectable mode function Function: ON/OFF detection between 2 electrodes Created on 04/08/2008 09:34 and updated on 10/04/2018 14:04 |
533-01 Page |
CS2.3 Free chlorine sensor, without effect from pH changes Page (193-04) For drinkable water monitoring Range: from 0.01 up to 10 ppm Output signal: 4-20 mA Pressure limit: 0.5 bar as a maximum Unnecessary zero adjustment Created on 27/09/2010 16:15 and updated on 10/04/2018 13:40 |
193-04 Page |
CC1 Free chlorine sensor, with isocyanuric acid Starting Up Notice (193-06)
Created on 27/12/2010 15:18 and updated on 10/04/2018 15:26 |
193-06 Starting Up Notice |
VEP K4-PPH Electrically actuated butterfly valves Page (914-06) ND 65 to ND 200 In-line pattern Electric actuator, Position index Manual operating for immediate action Created on 08/12/2011 15:57 and updated on 10/04/2018 14:43 |
914-06 Page |
GSM module WITH CABINET GSM and Wall mounting housing Page (248-03) • Compact cabinet IP 67 • Mains Power supply • Screw terminals Created on 10/12/2019 13:51 and updated on 10/12/2019 13:56 |
248-03 Page |
TS 13 Plastic temperature probe, Pt 100 Ω Page (613-01) • Plastic probe • Materials: PVC, PP, PVDF • Sensor: Pt 100 Ω at 0 °C • Range: from -20 °C up to 140 °C Created on 11/12/2019 16:45 and updated on 11/12/2019 16:46 |
613-01 Page |
SDD 910 Pressure relief valves Page (910-01) • All wet parts in plastic • Protection of pumps and piping • Body: PPG or PVDF • Unions: PVC, PP or PVDF • ND 10 and ND 15 • Adjustable trigger point: 0.5 ... 6 bar Created on 18/12/2019 10:33 and updated on 18/12/2019 10:39 |
910-01 Page |
FS4 Tank top level indicator Page (584-01) Local indicator, Tank top fitting For liquids, with or without particles Materials: PVC or PP • Direct reading • Materials PVC, PPH • Magnetic pointer for level switches • For tanks and drums Created on 10/10/2006 15:14 and updated on 11/12/2019 15:06 |
584-01 Page |
BAMOFLU 100 Flowsensor Starting Up Notice (780-01)
Created on 28/05/2007 14:40 and updated on 10/04/2018 15:57 |
780-01 Starting Up Notice |
BCP 48 Programmable counter Starting Up Notice (289-01)
Created on 06/09/2007 09:54 and updated on 10/04/2018 15:22 |
289-01 Starting Up Notice |
MNR 7 Ex Magnetic float level controller Starting Up Notice (550-03)
Created on 19/12/2008 17:53 and updated on 10/04/2018 15:41 |
550-03 Starting Up Notice |
BAMOBUL Bubbling... state of the art for level measurement! News () BAMOBUL is designed for a reliable and accurate measurement The bubbling measuring method is a non-age technique. It is still today, a serious alternative to ultra sonic transmitter, offering a trouble free use with foaming process and a long-term high... Created on 21/12/2009 17:35 and updated on 10/04/2018 16:23 |
News |
CL4.1 Free chlorine sensor, at constant pH Page (193-02) For process water Range: 0.5 to 200 ppm Output signal: 4-20 mA Pressure limit: 1 bar as a maximum Unnecessary zero adjustment Created on 15/10/2010 12:55 and updated on 17/12/2019 17:03 |
193-02 Page |
NIVOSTOP® / ACS Level controller, drinkable water agreement Page (523-01) For use in drinkable water , Food industry applications ACS Certificate = sanitary certification For use in drinkable water Food industry applications Built-in ballast Standard cable lengths 5, 10 and 20 m ACS Certificate = sanitary certification Created on 07/07/2011 09:49 and updated on 10/04/2018 14:01 |
523-01 Page |
VPP K4-PVDF Pneumatically actuated butterfly valves, single / double acting Starting Up Notice (913-09)
Created on 12/12/2011 17:43 and updated on 10/04/2018 16:05 |
913-09 Starting Up Notice |
NIVOSTOP® PR2 Heavy duty float level detector Page (522-05) • For sewage pumping/ lifting stations • Built-in counterweight • Robust design • High grade Neoprene cable • Cable length: 6, 10, 15, 20 m Created on 11/12/2019 10:49 and updated on 11/12/2019 10:55 |
522-05 Page |
BMV Metallic flow controllers with sided indicator Page (721-01) • Vertical mounting • Flow indicator with 1 adjustable contact • Material: Brass or AISI • Pressure limit up to 300 bar • Flow ranges within 0.1 ... 50 l/min Created on 17/12/2019 11:25 and updated on 17/12/2019 11:32 |
721-01 Page |
CBT Check valves Page (950-03) • Only one possible flow direction • Vertical or horizontal mounting • From ND 32 up to ND 300 With or without spring, Versions: Wafer or with loose flanges Created on 18/12/2019 16:29 and updated on 18/12/2019 16:33 |
950-03 Page |
ATEX certified's products for installation in dangerous zone News () ATEX Certification's products implies a certification in the ISO model. We lay out via our deutch subsidiary company this capacity. All a range in your disposition. Created on 08/10/2006 19:12 and updated on 11/04/2012 17:05 |
News |
BIF 6040 Ratemeter Totaliser Starting Up Notice (282-01)
Created on 11/10/2006 17:28 and updated on 10/04/2018 15:21 |
282-01 Starting Up Notice |
MAXIMAT LW C Leakage detection sensor Starting Up Notice (555-03)
Created on 12/03/2007 14:29 and updated on 10/04/2018 15:42 |
555-03 Starting Up Notice |
TURBICUBE In line turbidity transmitter Starting Up Notice (444-01)
Created on 20/06/2007 14:19 and updated on 10/04/2018 15:32 |
444-01 Starting Up Notice |
TWS Thermowells, welded body Page (635-01) • Body: welded tube • AISI 316 L, PVC, PPH, PVDF • Fittings: Threads: BSP or NPT ½'' ; NPT ¾'' Flanges: DN 32, 40 or 50 Created on 20/12/2007 14:35 and updated on 11/12/2019 16:55 |
635-01 Page |
LISA Liquid Intrusion Safe Alarming System Starting Up Notice (544-03)
Created on 10/04/2009 18:31 and updated on 10/04/2018 15:39 |
544-03 Starting Up Notice |
MAXIMAT LW VK Leakage detection sensor Starting Up Notice (555-08)
Created on 24/03/2010 10:38 and updated on 10/04/2018 15:44 |
555-08 Starting Up Notice |
PALINTEST POOLTEST 3 Photometer for chlorine and isocyanuric acid Starting Up Notice (190-10)
Created on 06/12/2010 15:15 and updated on 10/04/2018 15:22 |
190-10 Starting Up Notice |
VPP K4-PVC Pneumatically actuated butterfly valves, single / double acting Page (913-03) ND 65 to ND 200 In-line pattern Pneumatic actuator Single or double acting Position index Status NC or NO Standard compatibility: NAMUR VDI/VDE 3845 and ISO 5211 OPTIONS: Limit switch box Pilot valve Created on 07/12/2011 11:51 and updated on 10/04/2018 14:38 |
913-03 Page |
VE3V S4-PPH Electrically actuated 3-way ball valves Starting Up Notice (914-05)
Created on 28/03/2012 16:46 and updated on 10/04/2018 16:08 |
914-05 Starting Up Notice |
OZ10 Ozone sensor Page (193-22) - For clear water or sea water - Highly resistant to surfactants - Temperature : up to 45 °C - Pressure: up to 1 bar Created on 04/12/2019 16:46 and updated on 04/12/2019 16:56 |
193-22 Page |
LINEAR GRADUATED RULERS Page (581-01) - Metallic rulers for level indication - Mounting or vertical, or slope at 45° - Easy reading on large scale - Resistant to corrosion, climate strengths and seawater - Easy cleaning Created on 11/12/2019 14:10 and updated on 11/12/2019 14:14 |
581-01 Page |
IDP SERIES SPECIAL SCALES Page (730-06)
Created on 17/12/2019 15:39 and updated on 17/12/2019 15:41 |
730-06 Page |
General Information Category ()
Created on 23/09/2006 18:33 and updated on 27/03/2018 15:34 |
Category |
BAMOMATIC Electromagnetic flow-meter Page (775-01) Electromagnetic Flowmeter independent of fluid density, temperature or pressure, the most competitive on the market Created on 09/10/2006 16:13 and updated on 17/12/2019 16:43 |
775-01 Page |
MAXIMAT C Compact overfill sensor Page (555-01) Capacitive, high frequency, fail-safe detection For aggressive and conductive liquids Positive active alarm Auto diagnostic system and LED Approvals: DIBT Z-65.13-294, for overfillingdetection WHG§19, and VLAREM II Created on 13/02/2007 11:52 and updated on 10/04/2018 14:10 |
555-01 Page |
TRUBOMAT GAB In line turbidity transmitter Starting Up Notice (446-01)
Created on 31/07/2007 14:20 and updated on 10/04/2018 15:32 |
446-01 Starting Up Notice |
MAXIMAT SHRC Measuring transducer Starting Up Notice (555-06)
Created on 10/09/2008 16:01 and updated on 10/04/2018 15:43 |
555-06 Starting Up Notice |
MEMPRO Ex C Hydrostatic level transmitter Page (592-02) Fill level monitoring in ATEX Ex area For flammable liquids No moving parts Accurate and reliable measurement Output signal 4-20 mA, 2 wires Free from fluid viscosity or conductivity Scales: up to 4000 mm ATEX certification Created on 27/11/2009 10:59 and updated on 10/04/2018 14:22 |
592-02 Page |
CP2.1 Total chlorine sensor Page (193-05) - Water treatment, drinkable quality and sea water - Low incidence of pH changes - Surfactants: partial tolerance - Operating temperature 45 °C max. - Operating pressure 0.5 bar max. Created on 27/09/2010 16:33 and updated on 04/12/2019 15:05 |
193-05 Page |
CD 7 Chlorine dioxide sensor Starting Up Notice (193-11)
Created on 27/12/2010 15:25 and updated on 10/04/2018 15:26 |
193-11 Starting Up Notice |
VE2V S4-PVDF Electrically actuated 2-way ball valves Page (914-07) ND 10 to ND 100 In-line pattern Electric actuator, Position index Manual operating for immediate action Created on 08/12/2011 17:14 and updated on 10/04/2018 14:44 |
914-07 Page |
RDN 11 Intrinsic safety relay Page (251-01) • Intrinsic safety relay • Galvanic insulation • Protection for 1 contact or proximity sensor • Change over relay output Created on 10/12/2019 14:05 and updated on 10/12/2019 14:12 |
251-01 Page |
TW Thermowells Page (635-02) • Machined integral or welded • Large choice of materials • Process connections: Process: ½'', ¾''", 1" Welded fittings Flanges Created on 11/12/2019 16:56 and updated on 11/12/2019 16:58 |
635-02 Page |
V186 – V86 Pressure relief valves Page (911-04) • Body in PVC, PP or PVDF • Diaphragm: in EPDM with PTFE coat • V186: Spigot ends from ND 10 up to ND 50 • V 18 : Spigot ends from ND 65 up to ND 100 Created on 18/12/2019 10:40 and updated on 18/12/2019 10:56 |
911-04 Page |
GNR 5 PVC Level indicator Page (571-01) Local indicator, Level control Glass or transparent PVC tube Magnetic float: PP Connections: Flange or BSP threaded • Direct reading on site • Height: 40 to 500 cm • Wet parts: PVC, PPH • Seals: EPDM • Adjustable level switches Created on 10/10/2006 15:32 and updated on 11/12/2019 13:56 |
571-01 Page |
BAMOPHOX 322 Resistivity / Conductivity Starting Up Notice (322-01)
Created on 28/05/2007 14:45 and updated on 10/04/2018 15:28 |
322-01 Starting Up Notice |
RTM Continuous level transmitter Starting Up Notice (586-01)
Created on 14/09/2007 10:11 and updated on 10/04/2018 15:50 |
586-01 Starting Up Notice |
CONDUCTIVITY Typical measuring ranges Page (300-99)
Created on 22/12/2008 14:53 and updated on 10/04/2018 13:51 |
300-99 Page |
PHOXLOG: version 2.16 News () The software dedicated to the data logger BAMOPHOX is yet downloadable. Among new details, the inductive conductivity metre BAMOPHOX 322 TOR is included. Downloading: from the instructions manual page BAMOPHOX 106 Created on 21/12/2009 17:39 and updated on 10/04/2018 16:23 |
News |
GsM 24e Modem GSM / GPRS Page (248-01) Compact module M2M applications Supply required: 5.5....32 V dc 3 Inputs, 1 output Including: Serial cable Antenna Software Created on 28/10/2010 16:01 and updated on 10/04/2018 13:47 |
248-01 Page |
VP2V S4-PVC Pneumatically actuated 2-way ball valves, single / double acting Page (913-01) • PVC Valves from ND 10 up to ND 100 • Pneumatic actuator Single or double acting • Position pointer • OPTIONS: Limit switches box Pilot valve Created on 07/07/2011 13:07 and updated on 18/12/2019 11:14 |
913-01 Page |
SV61- BE41 Accessories for pneumatic actuators Page (913-10) • Pilot solenoid valves • Limit switches Box • Exhaust silencers • Exhaust dampers Created on 27/12/2011 18:05 and updated on 18/12/2019 11:37 |
913-10 Page |
BAMOPHAR 107 BAMOPHAR 107 Page (107-01) • Color touch screen • 2 existing scales: 0... 14 pH or ±1000 mV • Temperature compensation: Automatic or manual • 2 outputs 0/4-20mA (pH and T °C) • 4 relays (Thresholds, alarm and/or regulation) • Options: RS 422 /J-BUS + LOGGER... Created on 04/12/2019 10:33 and updated on 11/03/2020 14:57 |
107-01 Page |
NIVOSTOP® - MEZZO Float level regulator Page (522-06) • Regulation between two trigger points • Change-over microswitch • High switching power • Switching angle 120° • Cable lengths: 5, 10 and 20 m Created on 11/12/2019 10:57 and updated on 11/12/2019 11:01 |
522-06 Page |
CDA Flow controllers, metallic Page (722-01) • Operates in all positions • With 1 adjustable contact • Versions: Stainless steel or brass • Pressure: Up to 350 bar • Ranges: between 0.005 ...150 l/min Created on 17/12/2019 11:34 and updated on 17/12/2019 11:42 |
722-01 Page |
PM 958 Liquid dosing tube Page (958-01) • Liquid dosing tube • Tube in transparent PVC • Dimensions: Custom made • Option: Manual valves Created on 18/12/2019 16:35 and updated on 18/12/2019 16:38 |
958-01 Page |
Short Programme Category () The company BAMO Mesures SAS: European manufacturer of sensors and instruments for the monitoring and analysis of liquids BAMO has expertise in: Analysis and measuring of fluids, pH, chlorine, conductivity water hardness, turbidity and dissolved oxygen... Created on 08/10/2006 19:48 and updated on 12/04/2018 09:56 |
Category |
BAMOPHOX 759 Venturi channel flow calculator Starting Up Notice (759-02)
Created on 22/06/2007 16:15 and updated on 10/04/2018 15:56 |
759-02 Starting Up Notice |
MEMPRO Hydrostatic level transmitter Starting Up Notice (592-01)
Created on 26/12/2007 15:30 and updated on 10/04/2018 15:51 |
592-01 Starting Up Notice |
NIVOIL Alarm system for oil-water separators Starting Up Notice (531-01)
Created on 21/04/2009 14:11 and updated on 10/04/2018 15:37 |
531-01 Starting Up Notice |
Achemasia 2010 8th International Exhibition-Congress on Chemical Engineering and Biotechnology News () We shall exhibit between the 1 and 4 June 2010 in Beijing, our products in Achemasia 2010, the 8th International Exhibition-Congress on Chemical Engineering and Biotechnology Created on 26/04/2010 11:41 and updated on 10/04/2018 16:20 |
News |
BAMOSOFT Smart Water hardness monitor Page (375-01) Water hardness controller for water softening systems Preset limit value at 10% of raw water hardness BAMOSOFT Smart monitors a preset residual water hardness threshold value from the outlet of the water softener system. Threshold value is fixed at... Created on 06/12/2010 15:21 and updated on 10/12/2019 15:47 |
375-01 Page |
VP2V S4-PPH Pneumatically actuated 2-way ball valves, single / double acting Page (913-04) ND 10 to ND 100 In-line pattern Pneumatic actuator Single or double acting, Position index Status NC or NO Standard compatibility: NAMUR VDI/VDE 3845 and ISO 5211 OPTIONS : Limit switch box Pilot valve Created on 08/12/2011 09:52 and updated on 10/04/2018 14:39 |
913-04 Page |
VEP K4-PPH Electrically actuated butterfly valves Starting Up Notice (914-06)
Created on 28/03/2012 16:49 and updated on 10/04/2018 16:09 |
914-06 Starting Up Notice |
BAMOPHAR 194 Disinfectant monitoring and control Page (194-02) • Color touch screen • Input for 1 sensor 4-20 mA or 0-2 V • Existing scales: Free & total chlorine, chlorine dioxide Ozone, hydrogen peroxide, peracetic acid • 1 Input for Pt100 sensor • 2 Outputs 0/4-20mA (ppm or g/l and °C) • 4... Created on 10/12/2019 12:42 and updated on 10/12/2019 12:45 |
194-02 Page |
SFA, modular series Sets and kits Page (583-05) • For tanks with large heights • Easy carriage • Short delivery time • Level indicator protected by PVC tube • All sets and kits for assembly on site Created on 11/12/2019 14:54 and updated on 11/12/2019 14:55 |
583-05 Page |
Z60 / IDP-A Flow transmitter for IDP-A Page (730-07) • Flow-rate transmitter • For IDP-A, with magnetic diver • Output signal: 4-20 mA (3-wire) • Already set in factory • Plug in connector Created on 17/12/2019 15:43 and updated on 17/12/2019 15:57 |
730-07 Page |
News Category () General Information/ Created on 23/09/2006 18:33 and updated on 27/03/2018 15:42 |
Category |
Workshops Head Office Page () Our Facilities BAMO Mesures SAS in Argenteuil: we opened our new building in July 11, 2005 West front, main entrance It is an efficient building for manufacturing, with Stores, Commercial and Development facilities. The Head office is able to afford a... Created on 01/04/2012 11:17 and updated on 10/04/2018 16:26 |
Page |
pH and ORP 100 Category (100) User Manuals/ Created on 28/09/2006 22:53 and updated on 03/04/2018 11:21 |
100 Category |
pH and ORP 100 Category (100) General Catalog/ Created on 23/09/2006 18:42 and updated on 03/04/2018 11:27 |
100 Category |
BAMO France BAMO Mesures () Fabricant français de capteurs et d'instruments pour contrôle et analyse des fluides Created on 30/03/2012 17:18 and updated on 30/03/2012 17:20 |
|
Chlorine, disinfection 190 Category (190) General Catalog/ Created on 12/10/2010 18:54 and updated on 03/04/2018 11:28 |
190 Category |
Chlorine, disinfection 190 Category (190) User Manuals/ Created on 12/10/2010 19:00 and updated on 03/04/2018 11:21 |
190 Category |
About us Category () General Information/ Created on 23/09/2006 18:39 and updated on 27/03/2018 15:44 |
Category |
Data processors 200 Category (200) User Manuals/ Created on 28/09/2006 22:54 and updated on 03/04/2018 11:22 |
200 Category |
Data processors 200 Category (200) General Catalog/ Created on 23/09/2006 18:43 and updated on 03/04/2018 11:28 |
200 Category |
R&D For Your Safety Page () Product development is conducted in accordance with DIN EN ISO 9001:2000 procedures, as well as all applicable legal requirements and European standards. Testing in our own EMC lab, as well as by external approval authorities (i.e. TÜV, BIBt etc.),... Created on 10/10/2006 19:07 and updated on 10/04/2018 16:27 |
Page |
BAMO Deutschland BAMO IER () Innovative Messtechnik für Füllstand, Trübung und Analyse in Flüssigkeiten Created on 30/03/2012 17:22 and updated on 19/11/2013 16:07 |
|
BAMO Portugal GLOBALÁGUA, LDA () Instrumentação e Controlo de Águas Created on 02/02/2016 10:12 and updated on 02/02/2016 10:13 |
|
Contact Us Category () You can contact us Via: E-mail: Phone: Fax: Post: Link to: General Information/ Created on 04/04/2012 20:35 and updated on 27/03/2018 15:49 |
Category |
Conductivity 300 Category (300) User Manuals/ Created on 28/09/2006 22:54 and updated on 03/04/2018 11:22 |
300 Category |
BAMO International Category () General Information/ Created on 29/03/2012 09:42 and updated on 27/03/2018 15:50 |
Category |
Conductivity 300 Category (300) General Catalog/ Created on 23/09/2006 18:44 and updated on 03/04/2018 11:29 |
300 Category |
Manufacturing and assembly Page () All of the necessary technologies are at our disposal - in house. This guarantees us the flexibility we need to produce custom devices for you in the shortest time. Well trained employees, as well as documented procedures and work directives wich have... Created on 10/10/2006 19:10 and updated on 10/04/2018 16:27 |
Page |
Water hardness 375 Category (375) General Catalog/ Created on 12/10/2010 18:57 and updated on 03/04/2018 11:29 |
375 Category |
Turbidity 400 Category (400) User Manuals/ Created on 06/11/2006 15:33 and updated on 03/04/2018 11:23 |
400 Category |
BAMO Polska BAMO Polska Sp. z o.o. () Europejski producent czujników oraz urządzeń do kontroli i analizy cieczy Created on 10/09/2014 14:59 and updated on 24/09/2019 14:46 |
|
Testing Page () All electrical devices are subjected to strict, individual testing. Adherence to documented inspection procedures assures flawless functioning of all subassemblies and components during production, as well as after final assembly. Additional testing... Created on 10/10/2006 19:12 and updated on 10/04/2018 16:30 |
Page |
BAMO España GlobalAgua España () Fabricante europeo de sensores e instrumentos para líquidos Created on 30/03/2012 17:29 and updated on 24/10/2013 11:30 |
|
Turbidity 400 Category (400) General Catalog/ Created on 11/10/2006 17:33 and updated on 03/04/2018 11:29 |
400 Category |
Oxygen 450 Category (450) User Manuals/ Created on 28/09/2006 22:55 and updated on 03/04/2018 11:23 |
450 Category |
Oxygen 450 Category (450) General Catalog/ Created on 23/09/2006 18:46 and updated on 03/04/2018 11:30 |
450 Category |
Company History Page () BAMO MESURES SAS has been founded in 1978. Its capital is now 400 000 Euros. Since the beginning, the company has undergone a rapid development centring on industrial pH-meters and conductivity meters. BAMO is now well-known as a leader on the French... Created on 01/04/2012 11:08 and updated on 01/04/2012 11:31 |
Page |
Level 500 Category (500) User Manuals/ Created on 28/09/2006 22:55 and updated on 03/04/2018 11:24 |
500 Category |
Level 500 Category (500) General Catalog/ Created on 23/09/2006 18:46 and updated on 03/04/2018 11:31 |
500 Category |
BAMO International BAMO Mesures () European manufacturer of sensors and instruments for liquids Created on 30/03/2012 17:25 and updated on 30/03/2012 17:26 |
|
Temperature 600 Category (600) General Catalog/ Created on 23/09/2006 18:47 and updated on 03/04/2018 11:31 |
600 Category |
Flow 700 Category (700) User Manuals/ Created on 28/09/2006 22:56 and updated on 03/04/2018 11:24 |
700 Category |
Terms and Conditions of Sales Foreign Countries Page () Terms and conditions Unless otherwise stipulated in our offer or documentation, the terms and conditions of sale hereinafter apply to all services and products we commercialize. Created on 27/06/2011 17:18 and updated on 01/04/2012 11:35 |
Page |
Flow 700 Category (700) General Catalog/ Created on 23/09/2006 18:47 and updated on 03/04/2018 11:32 |
700 Category |
Pressure 800 Category (800) User Manuals/ Created on 15/09/2009 18:56 and updated on 03/04/2018 11:25 |
800 Category |
Pressure 800 Category (800) General Catalog/ Created on 15/09/2009 18:58 and updated on 03/04/2018 11:32 |
800 Category |
Plastic Valves 900 Category (900) User Manuals/ Created on 12/10/2010 19:11 and updated on 03/04/2018 11:25 |
900 Category |
Plastic Valves 900 Category (900) General Catalog/ Created on 23/09/2006 18:48 and updated on 03/04/2018 11:32 |
900 Category |
pH and ORP Category (100) Archives/ Created on 18/12/2019 17:22 and updated on 18/12/2019 17:23 |
100 Category |
Chlorine, Disinfection Category (190) Archives/ Created on 17/12/2019 17:02 and updated on 17/12/2019 17:03 |
190 Category |
Data processors 200 Category (200) Archives/ Created on 01/04/2012 15:07 and updated on 03/04/2018 11:26 |
200 Category |
Water hardness 375 Category () Archives/ Created on 04/02/2022 12:12 and updated on 04/02/2022 12:13 |
Category |
Turbidity Category () Archives/ Created on 04/02/2022 12:16 and updated on 04/02/2022 12:16 |
Category |
Oxygen Category () Archives/ Created on 04/02/2022 12:21 and updated on 04/02/2022 12:21 |
Category |
Level 500 Category (500) Archives/ Created on 01/04/2012 15:14 and updated on 03/04/2018 11:26 |
500 Category |
NIVOSTOP® - SS2 / HYP Level controller, all in Hypalon Page (520-02) Compatibility with basic, leak acid solutions and other aggressive chemicals Restrictions: due to the cable made of HYPALON and additives Adjustable ballast Maximal pressure 5.5 bar Maximal temperature 95°C Created on 26/11/2009 12:44 and updated on 10/04/2018 16:32 |
520-02 Page |
Flow 700 Category (700) Archives/ Created on 01/04/2012 15:15 and updated on 03/04/2018 11:27 |
700 Category |
9500 In-line electrode holders under pressure Page (142-01) • pH or ORP measurement • Construction: AISI 316 L • Pressure max. 16 bar • Temperature max. 110 °C • Fittings PG13.5 or BSP 1/2'' • For electrodes with fitting PG 13.5 • Process connections ND 15 to 32 mm Created on 08/02/2007 16:03 and updated on 04/12/2019 11:46 |
142-01 Page |
BAMOPHOX 192 Free Chlorine monitoring with Open cell amperometric method Page (192-02) Alphanumeric back lighted LCD display Friendly using menu Ranges from 0 to 5 mg/l for free chlorine -20...+160°C for temperature 2 analogical outputs 0/4-20mA, galvanic insulated 3 relay outputs (Normally Open contacts) 1 relay output for system... Created on 03/01/2007 11:10 and updated on 10/04/2018 13:38 |
192-02 Page |
GA 1 – GA 2 – GA 11 – GA 5 Armatures for turbidity control Page (421-01) Sensor fixture with emitter and receiver To use with the turbidity controller TRUBOMAT GS3 DN 15 to DN 200 In-line mounting or as a by-pass Construction PVC, PPH, Stainless steel Sensor fixture with emitter and receiver To use with the turbidity... Created on 21/02/2007 17:24 and updated on 10/04/2018 13:55 |
421-01 Page |
MUDLine® TGS Portable sludge level measuring instrument Page (426-01) Battery powered Mud level detection in primary and secondary clarifier, thickener and other applications Useful also in rotten black sludge Sludge level monitoring in small sewage plants Immersion depth: 10 m as a maximum Field portable device Sludge... Created on 03/11/2006 11:22 and updated on 10/04/2018 13:56 |
426-01 Page |
MUDLine® TGS Portable sludge level measuring instrument Starting Up Notice (426-01)
Created on 03/11/2006 11:28 and updated on 10/04/2018 15:31 |
426-01 Starting Up Notice |
BAMOPHOX 106 pH-Meter and mV-Meter Starting Up Notice (106-01)
Created on 16/02/2007 10:37 and updated on 10/04/2018 14:50 |
106-01 Starting Up Notice |
9090 Temperature compensation probe Page (150-02) • For mounting on holders 9200, 9500 et 9346 • Sensor Pt 100 Ω at 0 °C • Versions: Simplex or Duplex • Fitting PG 13.5 Created on 26/02/2007 10:23 and updated on 04/12/2019 12:18 |
150-02 Page |
pH and ORP ACCESSORIES Accessories Page (160-01)
Created on 26/02/2007 11:32 and updated on 04/12/2019 13:57 |
160-01 Page |
BAMOTOP 281 Frequency converter Page (281-01) • For any pulse emitter such as: BAMOFLU, BAMOTUR, Micro-stream, FFG, DF 140, Counters M, BAMOMATIC (12 V) • Input modes to configure • Range: 1 ... 25000 Hz • Galvanic insulated output • Current: 0/4-20 mA or 0-5/10 V • Response time to set... Created on 16/05/2007 10:16 and updated on 10/12/2019 14:22 |
281-01 Page |
BAMOPHOX 319 ML-DB Resistivity Metre Page (319-02) 2 independent sensors Input 1: range 0...20 MΩ Input 2: scalable range 0...20 MΩ / 0...2 MΩ Dedicated probes and sensors With Factor probe C = 0.01, 0.1, 1 and 10 2 adjustable analog output 0/4-20 mA 3 relay outputs (NO contact) Wall mounting IP 65 Created on 28/02/2007 09:33 and updated on 10/04/2018 13:51 |
319-02 Page |
BAMOPHOX 322 Resistivity / Conductivity Page (322-01) Monitor and controller MΩ - mS Programmable scales: 0...200 Ω up to 0...20 MΩ 0...2 μS up to 0...20 mS TOR version, 0...2 mS up to 0...2000 mS Convenient probes: With cell contant, 10 ; 1 ; 0.1 ; 0.01 or with TOR sensor Automatic or manual... Created on 09/10/2006 11:09 and updated on 10/04/2018 13:52 |
322-01 Page |
TCS 3020 Series Inductive conductivity probe in NORYL Page (364-01) Process measurement on line or by immersion For waste liquids Wide range of applications Large scales: from 0-2 to 0-2000 mS Probe material: NORYL • Range: from 10 μS/cm up to 2000 mS/cm • Material: NORYL • Temperature max. 105 °C • Low... Created on 28/02/2007 10:35 and updated on 10/12/2019 15:36 |
364-01 Page |
TRUBOMAT GS 3 Turbidity controller Page (410-01) ON/OFF turbidity Controller No effect of day light Output relay Adjustable delay Dysfunction indicator Created on 22/02/2007 18:05 and updated on 04/02/2022 12:17 |
410-01 Page |
BAMOPHOX 436 Turbidity monitor Page (436-01) Alphanumeric back lighted LCD display 2 models available: Panel mounting 72 x 144 (436E) Wall mounting IP 65 (436M) 3 relay outputs (Normally Open contacts) 1 relay output for system alarm 2 analogical outputs 0/4-20mA Scales NTU, FAU, mg/L, g/L, FNU ... Created on 15/02/2007 11:26 and updated on 04/02/2022 12:18 |
436-01 Page |
TURBICUBE In line turbidity transmitter Page (444-01) Drinking water plants Raw and waste water Phase separation, filtration Measuring range: 0.01...1000 FNU Output signal: 0/4-20 mA Immediate connection to BAMOPHOX monitor, data logger and regulator Flow-through in-line turbidimeter acc. ISO 7027... Created on 15/02/2007 11:05 and updated on 10/04/2018 13:57 |
444-01 Page |
MNR 7 Magnetic float level controller Page (550-01) Available in PVC – PPH - PVDF Up to 4 bi-stable change over contacts High switch power capacity Independent from density. Foam or vapors do not interfere Option for a continuous measurement Specific documentation: 586 = RTM/MNR7 Available in PVC –... Created on 26/02/2007 11:15 and updated on 10/04/2018 14:09 |
550-01 Page |
MNR 7 - 316L Stainless steel magnetic float level controller Page (550-02) Construction: stainless steel 316 Up to 4 bi-stable change over contacts High switch power capacity Independent from density. Foam or vapors do not interfere Option for a continuous measurement, see our specific documentation 586 about RTM/MNR7 Created on 26/02/2007 10:58 and updated on 10/04/2018 14:09 |
550-02 Page |
MNR 7 Ex Magnetic float level controller Page (550-03) Construction: stainless steel 1.4571 (316 Ti – AISI) Up to 4 bi-stable change over contacts ATEX II 1/2 G - EEx ib IIC T4 Construction: stainless steel 1.4571 (316 Ti – AISI) Up to 4 bi-stable change over contacts ATEX II 1/2 G - EEx ib IIC T4 Created on 26/02/2007 10:47 and updated on 10/04/2018 14:10 |
550-03 Page |
MAXIMAT LW CN-SDR Leakage detection transmitter Page (555-04) Capacitive, high frequency, fail-safe detection For aggressive and conductive liquids Two sensors Positive active alarm Auto diagnostic system and LED indicator WHG §19, approval DIBt-No.: Z-65.40-316 Created on 13/02/2007 15:13 and updated on 10/04/2018 14:11 |
555-04 Page |
MAXIMAT LWC-B Leakage detection sensor Page (555-05) Floor standing leakage detector Capacitive, high frequency, fail-safe detection For aggressive and electrically conductive liquids Positive active alarm Auto diagnostic system and LED indicator Created on 13/02/2007 15:47 and updated on 10/04/2018 14:12 |
555-05 Page |
MAXIMAT SHR CS Measuring transducer Page (555-06) Alarm signal relay for leakage or overfill transmitters Designed for overfill and leakage sensors MAXIMAT®C, MAXIMAT®VK.., MAXIMAT®LW.., CAPSYTRON SFL DIBT Approval Designed for overfill and leakage sensors MAXIMAT®C, ... Created on 13/02/2007 16:05 and updated on 10/04/2018 14:12 |
555-06 Page |
MAXIMAT TC4 Signaling device 4 sensor inputs Page (555-07) 4 surveying channels for leakage or overfill transmitters 4 surveying channels For compact overfill or leakage sensors MAXIMAT® C, MAXIMAT® VK..., MAXIMAT® LW... Microprocessor controlled Automatic sensor detection and survey Sensors and... Created on 26/02/2007 11:22 and updated on 10/04/2018 14:12 |
555-07 Page |
MAXIMAT LW VK Leakage detection sensor Page (555-08) Float level fail-safe detection For aggressive and non electrically conductive liquids Positive active alarm Auto diagnostic system and LED indication when in use with a SHR C transducer Approvals: DIBT Z-65.40-272, for leakage detection,... Created on 13/02/2007 17:48 and updated on 10/04/2018 14:13 |
555-08 Page |