Preview | There are 150 results for | Relevancy |
CS4 Free chlorine sensor Page (193-07) - Treatments of Fresh water and sea-water - Surfactants: partial tolerance - Low incidence of pH changes - Temperature: 45 °C max. - Pressure: 3 bar max. Created on 04/12/2019 15:32 and updated on 04/12/2019 15:45 |
193-07 Page |
GNR 5 / INOX Level indicator - Controller Page (575-01) • Direct reading • Construction: AISI 316 L and glass • C to C: Up to 2000 mm Created on 11/12/2019 14:02 and updated on 11/12/2019 14:05 |
575-01 Page |
IDP / PDP Fittings - Flanges - Seals Page (730-04)
Created on 17/12/2019 15:05 and updated on 17/12/2019 15:22 |
730-04 Page |
BIR 9000 Panel mounting indicator Page (222-02) Inputs: 4-20 mA, 0-10 mA, 0-10 V, 1-5 V Easy configuration Display 5 digits Housing 48 x 96 mm Front IP65 Main power 95…265 V AC Integrated sensor supply Min. / Max. values in memory Programmable ramp: 9 segments Created on 29/06/2007 11:54 and updated on 10/04/2018 16:31 |
222-02 Page |
BIR 4000 Panel mounting indicator Page (220-01) Analogic signal input, mA or V, DC Display 3 1⁄2 digits, red LED 14 mm height Small sized housing, 48x96x60 mm Front protection IP65 Removable screw connectors Main power supply 115 to 230 V – 50/60 Hz Power supply to sensor 24 V DC Optional 2 alarm... Created on 30/06/2008 13:44 and updated on 10/04/2018 16:30 |
220-01 Page |
MEMPRO S6 Hydrostatic level controller Starting Up Notice (592-03)
Created on 19/11/2009 16:47 and updated on 10/04/2018 15:51 |
592-03 Starting Up Notice |
AMPEROMETRIC SENSORS Page (193-01) • Free chlorine • Total chlorine • Chlorine dioxide • Hydrogen peroxide • Peracetic acid - Wide measuring ranges - Limits up to 70 °C and 8 bar - Unnecessary zero adjustment - Reliable measuring signal - Built-in temperature compensation... Created on 27/09/2010 16:07 and updated on 04/12/2019 14:38 |
193-01 Page |
CP 2.1 Total chlorine sensor, measuring free from pH changes Starting Up Notice (193-05)
Created on 27/12/2010 15:15 and updated on 10/04/2018 15:25 |
193-05 Starting Up Notice |
VE3V S4-PPH Electrically actuated 3-way ball valves Page (914-05) ND 10 to ND 50 In-line pattern Electric actuator, Position index Manual operating for immediate action Created on 08/12/2011 15:47 and updated on 10/04/2018 14:43 |
914-05 Page |
GsM 25e Modem GSM / GPRS Page (248-02) • Remote information report • 2G enclosure for supervision and alarm • 3 Inputs / 1 Output • Set up software included Created on 10/12/2019 13:45 and updated on 10/12/2019 13:50 |
248-02 Page |
MUDSENS Sludge level probe Page (599-02) • Ultrasonic probe • Level monitoring of sludge in sedimentation tanks • Advanced algorithm • Output 4-20 mA: representative of sludge level • Cleaning with compressed air • User-friendly menu Created on 11/12/2019 16:31 and updated on 11/12/2019 16:34 |
599-02 Page |
V182 – V82 Pressure reducing valves Page (906-03) • Body : PVC, PP or PVDF • Diaphragm: in EPDM with PTFE coat • V182: Spigot ends from ND 10 up to ND 50 • V 82 : Spigot ends from ND 65 up to ND 100 • Gauge 0-10 bar, with built-in gauge guard Created on 18/12/2019 10:24 and updated on 18/12/2019 10:31 |
906-03 Page |
BIR 8004 SERIE Numerical Indicator 4 Normaly Open Contacts Page (222-01) Imput 4 - 20 mA 4 setting NO contacts Supply 230 V - 50/60 Hz Simplified setting Display +/- 2000 pts Display 3 1/2 digits LCD 12,5 mm Pannel mounting IP 55 Removable wiring connectors Sensor supply 230 V Output NO relays contacts Adjustable hyteresis... Created on 09/10/2006 18:01 and updated on 10/04/2018 16:31 |
222-01 Page |
BAMOPHOX 436 Turbidity monitor Starting Up Notice (436-02)
Created on 23/05/2007 18:04 and updated on 10/04/2018 15:31 |
436-02 Starting Up Notice |
BCP 48 Programmable counter Page (289-01) Universal and simple Double back-lighted LCD display Main counter 8 digits Totalizer Second counter 6 digits Batch counter with two pre-setting 4 programming mode Supply sensor 24 V DIN 48 x 48 enclosure box Created on 06/09/2007 09:29 and updated on 10/04/2018 13:49 |
289-01 Page |
MNR 7 Stainless steel Stainless steel magnetic float level controller Starting Up Notice (550-02)
Created on 19/12/2008 17:12 and updated on 10/04/2018 15:41 |
550-02 Starting Up Notice |
MUDLINE Sludge level controller News () Perfect control of sludge level in sedimentation basin. Easy, quick and accurate measurement New answers for operators of WWTP to their needs of reliable information on sludge levels. The MUDLINE is an innovation on these applications: - Autonomous -... Created on 21/12/2009 17:28 and updated on 10/04/2018 16:23 |
News |
VP3V S4-PVDF Pneumatically actuated 3-way ball valves, single / double acting Starting Up Notice (913-08)
Created on 12/12/2011 17:41 and updated on 10/04/2018 16:05 |
913-08 Starting Up Notice |
NIVOSTOP® / C Float level detector Page (520-04) • For aggressive liquids • Cable in FEP, seal in FPM, body in PP • Temperature max. 100 °C • Built-in counterweight • Standard cable lengths: 5, 10 & 20 m Created on 11/12/2019 10:41 and updated on 11/12/2019 10:48 |
520-04 Page |
SIG 4.0 Analogue transmitter for flow controllers Page (720-10) • For flow controllers • Output: 4 ... 20 mA or 0 ... 10 V • Accuracy: ±10 % FS • Already set in factory Created on 17/12/2019 11:17 and updated on 17/12/2019 11:23 |
720-10 Page |
BV 91 - BV 95 Vent valves Page (949-02) • Air inlet and outlet controls • Body: PVC, PP or PVDF • From ND 10 up to ND 80 • BV 91 free ball valve, for tank ventilation • BV 95 ball valve, spring assistance, for tank ventilation & vacuum breaking Created on 18/12/2019 16:21 and updated on 18/12/2019 16:25 |
949-02 Page |
9200 In-line holders for 1 to 3 electrodes, pH or ORP Page (140-01) pH or ORP continuous flow cells For 1 to 3 electrodes pH, mV PVC or PPH material Various process connections available • Holder for 1, 2 or 3 electrodes • Construction: PVC or PPH • Process fitting: Union ND 20, diam. 25 mm Created on 05/10/2006 17:31 and updated on 04/12/2019 11:17 |
140-01 Page |
9423 In-line probe electrode holder Starting Up Notice (141-01)
Created on 15/06/2007 17:26 and updated on 10/04/2018 15:18 |
141-01 Starting Up Notice |
TS 16 Temperature sensor Page (616-01) Pt 100 Ω at 0 °C Measurement range -200 ...+600 °C Stainless steel stem Waterproof cable output Created on 20/12/2007 14:29 and updated on 10/04/2018 14:25 |
616-01 Page |
MAXITOP Compact overfill sensor Page (556-01) Universal use for electrically conductive, non-flammable water endangering liquids According WHG § 19 in Germany, the series is called MAXIMAT® C. No moving parts Process connection BSP 2", PVC, sliding Stem PEHD: Ø 40 mm Adjustable immersion... Created on 25/03/2009 14:56 and updated on 10/04/2018 14:15 |
556-01 Page |
MAXITOP LWC Leakage detection probe Page (556-03) Leakage sensor Universal use for electrically conductive, non-flammable water endangering liquids According WHG § 19 in Germany, the series is called MAXIMAT® LW-C. Stem: PEHD, Ø 40 mm (Ø 25 on request) With fastening angle and adjustable... Created on 10/03/2010 15:12 and updated on 10/04/2018 14:15 |
556-03 Page |
Pooltest 3 Photometer for chlorine and isocyanuric acid Page (190-10) • For swimming pools • Measuring ranges Chlorine from 0.01 to 5 & 10 mg/l Isocyanuric acid from 2 to 200 mg/l pH from 6.5 to 8.4 • Delivered ready to use Created on 06/12/2010 15:06 and updated on 04/12/2019 14:19 |
190-10 Page |
VP3V S4-PVC Pneumatic 3-way ball valves single or double acting Page (913-02) ND 10 to ND 50 In-line pattern Pneumatic actuator Single or double acting Position index Status NC or NO • PVC Valves from ND 10 up to ND 50 • Pneumatic actuator Single or double acting • Position pointer • Options: Limit switches box Pilot... Created on 07/12/2011 11:38 and updated on 18/12/2019 11:21 |
913-02 Page |
VE2V S4-PPH Electrically actuated 2-way ball valves Starting Up Notice (914-04)
Created on 28/03/2012 16:42 and updated on 10/04/2018 16:08 |
914-04 Starting Up Notice |
OZ7 Ozone sensor Page (193-21) - Drinkable water, sea water - Surfactants: partial tolerance - Temperature: 45 °C max. - Pressure: 1 bar max. Created on 04/12/2019 16:33 and updated on 04/12/2019 16:44 |
193-21 Page |
JEPA 580 Level gauge Electro-pneumatic, autonomous Page (580-02) • For compatible liquids (diesel, water, ...) • Displays in cm or Volume • For any kind of tanks • Battery operated • Height max.: Diesel 3 m; Water 2.5 m Created on 11/12/2019 14:06 and updated on 11/12/2019 14:08 |
580-02 Page |
IDP Plastic flow indicator Page (730-05) • Direct reading • All wet parts in plastics • Measuring tubes: PVC or Polysulfone • Ranges: Up to 60 m³/h Specific scales for Air, HCl, NaOH, etc. • Options: Adjustable contacts, ruler with 4-20 mA transmitter Created on 17/12/2019 15:24 and updated on 17/12/2019 15:35 |
730-05 Page |
RTM Continuous level transmitter Page (586-01) Signal output: 4-20 mA Step: 10 mm The RTM is adapted to our level indicators MAGTOP, SFA, MNR 6 and MNR 7. Continuous level transmitter Output 4-20 mA or Ohm Accuracy: 10 mm Direct mounting above the tank Available for MAGTOP and SFA Created on 27/03/2007 14:20 and updated on 10/04/2018 14:20 |
586-01 Page |
TRUBOMAT GS3 Turbidity controller Starting Up Notice (410-01)
Created on 30/07/2007 16:51 and updated on 10/04/2018 15:31 |
410-01 Starting Up Notice |
RXM 2851 Resistive amplifier relay Page (533-01) For highly resistive medium Input adjustable from 4.7 to 100 MΩ Adjustable sensitivity from the front Selectable mode function Function: ON/OFF detection between 2 electrodes Created on 04/08/2008 09:34 and updated on 10/04/2018 14:04 |
533-01 Page |
CS2.3 Free chlorine sensor, without effect from pH changes Page (193-04) For drinkable water monitoring Range: from 0.01 up to 10 ppm Output signal: 4-20 mA Pressure limit: 0.5 bar as a maximum Unnecessary zero adjustment Created on 27/09/2010 16:15 and updated on 10/04/2018 13:40 |
193-04 Page |
CC1 Free chlorine sensor, with isocyanuric acid Starting Up Notice (193-06)
Created on 27/12/2010 15:18 and updated on 10/04/2018 15:26 |
193-06 Starting Up Notice |
VEP K4-PPH Electrically actuated butterfly valves Page (914-06) ND 65 to ND 200 In-line pattern Electric actuator, Position index Manual operating for immediate action Created on 08/12/2011 15:57 and updated on 10/04/2018 14:43 |
914-06 Page |
GSM module WITH CABINET GSM and Wall mounting housing Page (248-03) • Compact cabinet IP 67 • Mains Power supply • Screw terminals Created on 10/12/2019 13:51 and updated on 10/12/2019 13:56 |
248-03 Page |
TS 13 Plastic temperature probe, Pt 100 Ω Page (613-01) • Plastic probe • Materials: PVC, PP, PVDF • Sensor: Pt 100 Ω at 0 °C • Range: from -20 °C up to 140 °C Created on 11/12/2019 16:45 and updated on 11/12/2019 16:46 |
613-01 Page |
SDD 910 Pressure relief valves Page (910-01) • All wet parts in plastic • Protection of pumps and piping • Body: PPG or PVDF • Unions: PVC, PP or PVDF • ND 10 and ND 15 • Adjustable trigger point: 0.5 ... 6 bar Created on 18/12/2019 10:33 and updated on 18/12/2019 10:39 |
910-01 Page |
FS4 Tank top level indicator Page (584-01) Local indicator, Tank top fitting For liquids, with or without particles Materials: PVC or PP • Direct reading • Materials PVC, PPH • Magnetic pointer for level switches • For tanks and drums Created on 10/10/2006 15:14 and updated on 11/12/2019 15:06 |
584-01 Page |
BAMOFLU 100 Flowsensor Starting Up Notice (780-01)
Created on 28/05/2007 14:40 and updated on 10/04/2018 15:57 |
780-01 Starting Up Notice |
BCP 48 Programmable counter Starting Up Notice (289-01)
Created on 06/09/2007 09:54 and updated on 10/04/2018 15:22 |
289-01 Starting Up Notice |
MNR 7 Ex Magnetic float level controller Starting Up Notice (550-03)
Created on 19/12/2008 17:53 and updated on 10/04/2018 15:41 |
550-03 Starting Up Notice |
BAMOBUL Bubbling... state of the art for level measurement! News () BAMOBUL is designed for a reliable and accurate measurement The bubbling measuring method is a non-age technique. It is still today, a serious alternative to ultra sonic transmitter, offering a trouble free use with foaming process and a long-term high... Created on 21/12/2009 17:35 and updated on 10/04/2018 16:23 |
News |
CL4.1 Free chlorine sensor, at constant pH Page (193-02) For process water Range: 0.5 to 200 ppm Output signal: 4-20 mA Pressure limit: 1 bar as a maximum Unnecessary zero adjustment Created on 15/10/2010 12:55 and updated on 17/12/2019 17:03 |
193-02 Page |
NIVOSTOP® / ACS Level controller, drinkable water agreement Page (523-01) For use in drinkable water , Food industry applications ACS Certificate = sanitary certification For use in drinkable water Food industry applications Built-in ballast Standard cable lengths 5, 10 and 20 m ACS Certificate = sanitary certification Created on 07/07/2011 09:49 and updated on 10/04/2018 14:01 |
523-01 Page |
VPP K4-PVDF Pneumatically actuated butterfly valves, single / double acting Starting Up Notice (913-09)
Created on 12/12/2011 17:43 and updated on 10/04/2018 16:05 |
913-09 Starting Up Notice |
NIVOSTOP® PR2 Heavy duty float level detector Page (522-05) • For sewage pumping/ lifting stations • Built-in counterweight • Robust design • High grade Neoprene cable • Cable length: 6, 10, 15, 20 m Created on 11/12/2019 10:49 and updated on 11/12/2019 10:55 |
522-05 Page |
BMV Metallic flow controllers with sided indicator Page (721-01) • Vertical mounting • Flow indicator with 1 adjustable contact • Material: Brass or AISI • Pressure limit up to 300 bar • Flow ranges within 0.1 ... 50 l/min Created on 17/12/2019 11:25 and updated on 17/12/2019 11:32 |
721-01 Page |
CBT Check valves Page (950-03) • Only one possible flow direction • Vertical or horizontal mounting • From ND 32 up to ND 300 With or without spring, Versions: Wafer or with loose flanges Created on 18/12/2019 16:29 and updated on 18/12/2019 16:33 |
950-03 Page |
ATEX certified's products for installation in dangerous zone News () ATEX Certification's products implies a certification in the ISO model. We lay out via our deutch subsidiary company this capacity. All a range in your disposition. Created on 08/10/2006 19:12 and updated on 11/04/2012 17:05 |
News |
BIF 6040 Ratemeter Totaliser Starting Up Notice (282-01)
Created on 11/10/2006 17:28 and updated on 10/04/2018 15:21 |
282-01 Starting Up Notice |
MAXIMAT LW C Leakage detection sensor Starting Up Notice (555-03)
Created on 12/03/2007 14:29 and updated on 10/04/2018 15:42 |
555-03 Starting Up Notice |
TURBICUBE In line turbidity transmitter Starting Up Notice (444-01)
Created on 20/06/2007 14:19 and updated on 10/04/2018 15:32 |
444-01 Starting Up Notice |
TWS Thermowells, welded body Page (635-01) • Body: welded tube • AISI 316 L, PVC, PPH, PVDF • Fittings: Threads: BSP or NPT ½'' ; NPT ¾'' Flanges: DN 32, 40 or 50 Created on 20/12/2007 14:35 and updated on 11/12/2019 16:55 |
635-01 Page |
LISA Liquid Intrusion Safe Alarming System Starting Up Notice (544-03)
Created on 10/04/2009 18:31 and updated on 10/04/2018 15:39 |
544-03 Starting Up Notice |
MAXIMAT LW VK Leakage detection sensor Starting Up Notice (555-08)
Created on 24/03/2010 10:38 and updated on 10/04/2018 15:44 |
555-08 Starting Up Notice |
PALINTEST POOLTEST 3 Photometer for chlorine and isocyanuric acid Starting Up Notice (190-10)
Created on 06/12/2010 15:15 and updated on 10/04/2018 15:22 |
190-10 Starting Up Notice |
VPP K4-PVC Pneumatically actuated butterfly valves, single / double acting Page (913-03) ND 65 to ND 200 In-line pattern Pneumatic actuator Single or double acting Position index Status NC or NO Standard compatibility: NAMUR VDI/VDE 3845 and ISO 5211 OPTIONS: Limit switch box Pilot valve Created on 07/12/2011 11:51 and updated on 10/04/2018 14:38 |
913-03 Page |
VE3V S4-PPH Electrically actuated 3-way ball valves Starting Up Notice (914-05)
Created on 28/03/2012 16:46 and updated on 10/04/2018 16:08 |
914-05 Starting Up Notice |
OZ10 Ozone sensor Page (193-22) - For clear water or sea water - Highly resistant to surfactants - Temperature : up to 45 °C - Pressure: up to 1 bar Created on 04/12/2019 16:46 and updated on 04/12/2019 16:56 |
193-22 Page |
LINEAR GRADUATED RULERS Page (581-01) - Metallic rulers for level indication - Mounting or vertical, or slope at 45° - Easy reading on large scale - Resistant to corrosion, climate strengths and seawater - Easy cleaning Created on 11/12/2019 14:10 and updated on 11/12/2019 14:14 |
581-01 Page |
IDP SERIES SPECIAL SCALES Page (730-06)
Created on 17/12/2019 15:39 and updated on 17/12/2019 15:41 |
730-06 Page |
General Information Category ()
Created on 23/09/2006 18:33 and updated on 27/03/2018 15:34 |
Category |
BAMOMATIC Electromagnetic flow-meter Page (775-01) Electromagnetic Flowmeter independent of fluid density, temperature or pressure, the most competitive on the market Created on 09/10/2006 16:13 and updated on 17/12/2019 16:43 |
775-01 Page |
MAXIMAT C Compact overfill sensor Page (555-01) Capacitive, high frequency, fail-safe detection For aggressive and conductive liquids Positive active alarm Auto diagnostic system and LED Approvals: DIBT Z-65.13-294, for overfillingdetection WHG§19, and VLAREM II Created on 13/02/2007 11:52 and updated on 10/04/2018 14:10 |
555-01 Page |
TRUBOMAT GAB In line turbidity transmitter Starting Up Notice (446-01)
Created on 31/07/2007 14:20 and updated on 10/04/2018 15:32 |
446-01 Starting Up Notice |
MAXIMAT SHRC Measuring transducer Starting Up Notice (555-06)
Created on 10/09/2008 16:01 and updated on 10/04/2018 15:43 |
555-06 Starting Up Notice |
MEMPRO Ex C Hydrostatic level transmitter Page (592-02) Fill level monitoring in ATEX Ex area For flammable liquids No moving parts Accurate and reliable measurement Output signal 4-20 mA, 2 wires Free from fluid viscosity or conductivity Scales: up to 4000 mm ATEX certification Created on 27/11/2009 10:59 and updated on 10/04/2018 14:22 |
592-02 Page |
CP2.1 Total chlorine sensor Page (193-05) - Water treatment, drinkable quality and sea water - Low incidence of pH changes - Surfactants: partial tolerance - Operating temperature 45 °C max. - Operating pressure 0.5 bar max. Created on 27/09/2010 16:33 and updated on 04/12/2019 15:05 |
193-05 Page |
CD 7 Chlorine dioxide sensor Starting Up Notice (193-11)
Created on 27/12/2010 15:25 and updated on 10/04/2018 15:26 |
193-11 Starting Up Notice |
VE2V S4-PVDF Electrically actuated 2-way ball valves Page (914-07) ND 10 to ND 100 In-line pattern Electric actuator, Position index Manual operating for immediate action Created on 08/12/2011 17:14 and updated on 10/04/2018 14:44 |
914-07 Page |
RDN 11 Intrinsic safety relay Page (251-01) • Intrinsic safety relay • Galvanic insulation • Protection for 1 contact or proximity sensor • Change over relay output Created on 10/12/2019 14:05 and updated on 10/12/2019 14:12 |
251-01 Page |
TW Thermowells Page (635-02) • Machined integral or welded • Large choice of materials • Process connections: Process: ½'', ¾''", 1" Welded fittings Flanges Created on 11/12/2019 16:56 and updated on 11/12/2019 16:58 |
635-02 Page |
V186 – V86 Pressure relief valves Page (911-04) • Body in PVC, PP or PVDF • Diaphragm: in EPDM with PTFE coat • V186: Spigot ends from ND 10 up to ND 50 • V 18 : Spigot ends from ND 65 up to ND 100 Created on 18/12/2019 10:40 and updated on 18/12/2019 10:56 |
911-04 Page |
GNR 5 PVC Level indicator Page (571-01) Local indicator, Level control Glass or transparent PVC tube Magnetic float: PP Connections: Flange or BSP threaded • Direct reading on site • Height: 40 to 500 cm • Wet parts: PVC, PPH • Seals: EPDM • Adjustable level switches Created on 10/10/2006 15:32 and updated on 11/12/2019 13:56 |
571-01 Page |
BAMOPHOX 322 Resistivity / Conductivity Starting Up Notice (322-01)
Created on 28/05/2007 14:45 and updated on 10/04/2018 15:28 |
322-01 Starting Up Notice |
RTM Continuous level transmitter Starting Up Notice (586-01)
Created on 14/09/2007 10:11 and updated on 10/04/2018 15:50 |
586-01 Starting Up Notice |
CONDUCTIVITY Typical measuring ranges Page (300-99)
Created on 22/12/2008 14:53 and updated on 10/04/2018 13:51 |
300-99 Page |
PHOXLOG: version 2.16 News () The software dedicated to the data logger BAMOPHOX is yet downloadable. Among new details, the inductive conductivity metre BAMOPHOX 322 TOR is included. Downloading: from the instructions manual page BAMOPHOX 106 Created on 21/12/2009 17:39 and updated on 10/04/2018 16:23 |
News |
GsM 24e Modem GSM / GPRS Page (248-01) Compact module M2M applications Supply required: 5.5....32 V dc 3 Inputs, 1 output Including: Serial cable Antenna Software Created on 28/10/2010 16:01 and updated on 10/04/2018 13:47 |
248-01 Page |
VP2V S4-PVC Pneumatically actuated 2-way ball valves, single / double acting Page (913-01) • PVC Valves from ND 10 up to ND 100 • Pneumatic actuator Single or double acting • Position pointer • OPTIONS: Limit switches box Pilot valve Created on 07/07/2011 13:07 and updated on 18/12/2019 11:14 |
913-01 Page |
SV61- BE41 Accessories for pneumatic actuators Page (913-10) • Pilot solenoid valves • Limit switches Box • Exhaust silencers • Exhaust dampers Created on 27/12/2011 18:05 and updated on 18/12/2019 11:37 |
913-10 Page |
BAMOPHAR 107 BAMOPHAR 107 Page (107-01) • Color touch screen • 2 existing scales: 0... 14 pH or ±1000 mV • Temperature compensation: Automatic or manual • 2 outputs 0/4-20mA (pH and T °C) • 4 relays (Thresholds, alarm and/or regulation) • Options: RS 422 /J-BUS + LOGGER... Created on 04/12/2019 10:33 and updated on 11/03/2020 14:57 |
107-01 Page |
NIVOSTOP® - MEZZO Float level regulator Page (522-06) • Regulation between two trigger points • Change-over microswitch • High switching power • Switching angle 120° • Cable lengths: 5, 10 and 20 m Created on 11/12/2019 10:57 and updated on 11/12/2019 11:01 |
522-06 Page |
CDA Flow controllers, metallic Page (722-01) • Operates in all positions • With 1 adjustable contact • Versions: Stainless steel or brass • Pressure: Up to 350 bar • Ranges: between 0.005 ...150 l/min Created on 17/12/2019 11:34 and updated on 17/12/2019 11:42 |
722-01 Page |
PM 958 Liquid dosing tube Page (958-01) • Liquid dosing tube • Tube in transparent PVC • Dimensions: Custom made • Option: Manual valves Created on 18/12/2019 16:35 and updated on 18/12/2019 16:38 |
958-01 Page |
Short Programme Category () The company BAMO Mesures SAS: European manufacturer of sensors and instruments for the monitoring and analysis of liquids BAMO has expertise in: Analysis and measuring of fluids, pH, chlorine, conductivity water hardness, turbidity and dissolved oxygen... Created on 08/10/2006 19:48 and updated on 12/04/2018 09:56 |
Category |
BAMOPHOX 759 Venturi channel flow calculator Starting Up Notice (759-02)
Created on 22/06/2007 16:15 and updated on 10/04/2018 15:56 |
759-02 Starting Up Notice |
MEMPRO Hydrostatic level transmitter Starting Up Notice (592-01)
Created on 26/12/2007 15:30 and updated on 10/04/2018 15:51 |
592-01 Starting Up Notice |
NIVOIL Alarm system for oil-water separators Starting Up Notice (531-01)
Created on 21/04/2009 14:11 and updated on 10/04/2018 15:37 |
531-01 Starting Up Notice |
Achemasia 2010 8th International Exhibition-Congress on Chemical Engineering and Biotechnology News () We shall exhibit between the 1 and 4 June 2010 in Beijing, our products in Achemasia 2010, the 8th International Exhibition-Congress on Chemical Engineering and Biotechnology Created on 26/04/2010 11:41 and updated on 10/04/2018 16:20 |
News |
BAMOSOFT Smart Water hardness monitor Page (375-01) Water hardness controller for water softening systems Preset limit value at 10% of raw water hardness BAMOSOFT Smart monitors a preset residual water hardness threshold value from the outlet of the water softener system. Threshold value is fixed at... Created on 06/12/2010 15:21 and updated on 10/12/2019 15:47 |
375-01 Page |
VP2V S4-PPH Pneumatically actuated 2-way ball valves, single / double acting Page (913-04) ND 10 to ND 100 In-line pattern Pneumatic actuator Single or double acting, Position index Status NC or NO Standard compatibility: NAMUR VDI/VDE 3845 and ISO 5211 OPTIONS : Limit switch box Pilot valve Created on 08/12/2011 09:52 and updated on 10/04/2018 14:39 |
913-04 Page |
VEP K4-PPH Electrically actuated butterfly valves Starting Up Notice (914-06)
Created on 28/03/2012 16:49 and updated on 10/04/2018 16:09 |
914-06 Starting Up Notice |
BAMOPHAR 194 Disinfectant monitoring and control Page (194-02) • Color touch screen • Input for 1 sensor 4-20 mA or 0-2 V • Existing scales: Free & total chlorine, chlorine dioxide Ozone, hydrogen peroxide, peracetic acid • 1 Input for Pt100 sensor • 2 Outputs 0/4-20mA (ppm or g/l and °C) • 4... Created on 10/12/2019 12:42 and updated on 10/12/2019 12:45 |
194-02 Page |
SFA, modular series Sets and kits Page (583-05) • For tanks with large heights • Easy carriage • Short delivery time • Level indicator protected by PVC tube • All sets and kits for assembly on site Created on 11/12/2019 14:54 and updated on 11/12/2019 14:55 |
583-05 Page |
Z60 / IDP-A Flow transmitter for IDP-A Page (730-07) • Flow-rate transmitter • For IDP-A, with magnetic diver • Output signal: 4-20 mA (3-wire) • Already set in factory • Plug in connector Created on 17/12/2019 15:43 and updated on 17/12/2019 15:57 |
730-07 Page |
FFG Turbine Flowmeter Page (784-01) Totalization and low flow measure Compact equipment PVDF, Polysulfon and arnite execution Easy dismantling Measure range: 6 to 720 l/h Accuracy ±1% Frequency output: high resolution Connection 1/4" GM Created on 09/10/2006 16:20 and updated on 10/04/2018 14:35 |
784-01 Page |
MAXIMAT VK C Compact overfill sensor Page (555-02) Float level detection For aggressive and non electrically conductive liquids Positive active alarm Auto diagnostic system and LED indication Approvals: DIBT Z-65.13-294, for overfilling detection WHG§19, and VLAREM II Created on 13/02/2007 14:31 and updated on 10/04/2018 14:11 |
555-02 Page |
CP1 Immersion probe for turbidity control Page (425-01) ON/OFF turbidity control PVC probe, IP68 Optical measurement in Infra Red wavelengths Detection: from 50 to 1300 FAU or from 600 to 3000 FAU Immersion depth of 10 m as a maximum Fitting and configuration easy with our TRUBOMAT GS3 controller Created on 30/03/2007 13:37 and updated on 10/04/2018 13:56 |
425-01 Page |
9336 pH - ORP Immersion probes Starting Up Notice (130-01)
Created on 06/08/2007 17:34 and updated on 10/04/2018 15:15 |
130-01 Starting Up Notice |
BAMOMATIC Electromagnetic Flowmeter Starting Up Notice (775-01)
Created on 14/10/2008 18:04 and updated on 10/04/2018 15:57 |
775-01 Starting Up Notice |
MEMPRO Ex C Hydrostatic level transmitter Starting Up Notice (592-02)
Created on 27/11/2009 11:11 and updated on 10/04/2018 15:51 |
592-02 Starting Up Notice |
CC1 Sensor for free chlorine with stabilizers Page (193-06) Closed cell with diaphragm, 3 electrodes For swimming pool water monitoring Water sample may not content surface-active additives. Range: 0.01 to 10 ppm Output signal: 4-20 mA Pressure limit: 0.5 bar Temperature limit: 1...45 °C - For swimming pools... Created on 27/09/2010 16:53 and updated on 04/12/2019 15:30 |
193-06 Page |
AS2 & AS3 Chlorine dioxide and free chlorine sensors Starting Up Notice (193-13)
Created on 27/12/2010 15:58 and updated on 10/04/2018 15:27 |
193-13 Starting Up Notice |
VE3V S4-PVDF Electrically actuated 3-way PVDF ball valves Page (914-08) • PVDF valves from ND10 up to ND50 • Radial mounting and dismounting • Electric actuator with position pointer and manual operating for emergency Created on 08/12/2011 17:32 and updated on 18/12/2019 15:12 |
914-08 Page |
PKK Multitask relay Page (251-02) • Galvanic isolation • input 4-20 mA or potential free contact • Intrinsic safety • Settings on relay outputs • Power supply to sensor Created on 10/12/2019 14:14 and updated on 10/12/2019 14:17 |
251-02 Page |
CDP Paddle flow controller Page (710-01) • 1 Reed contact N.O. / N.C. • Stainless steel or brass versions • Low pressure drop • Fittings: On tee up to ND50 or BSP ½'' Created on 17/12/2019 09:58 and updated on 17/12/2019 10:09 |
710-01 Page |
DHV 712-R Pressure relief valve Page (911-05) • Protection of pumps and pipings • Body: PVC-U, PP or PVDF • Diaphragm: EPDM coated with PTFE • Fittings from ND 10 to ND 50 Created on 18/12/2019 10:58 and updated on 18/12/2019 11:03 |
911-05 Page |
User Manuals Category ()
Created on 28/09/2006 22:50 and updated on 27/03/2018 16:27 |
Category |
MAGTOP Level indicator Page (560-01) Indicators allow an instantaneous level liquid reading in a tank, even if this one is opaque Created on 10/10/2006 15:41 and updated on 11/12/2019 13:41 |
560-01 Page |
MEMPRO Hydrostatic level transmitter Page (592-01) Universal use in open tanks Reliable operation, even with aggressive, viscous, contaminated and crystallising liquids. The measuring cell is not in contact with the medium. Range: up to 10 m WC Wetted parts: PVC, PP, EPDM or stainless steel Measuring... Created on 29/05/2007 15:47 and updated on 10/04/2018 14:21 |
592-01 Page |
BAMOPHOX 319 ML-DB Resistivity Metre Starting Up Notice (319-02)
Created on 17/09/2007 17:38 and updated on 10/04/2018 15:28 |
319-02 Starting Up Notice |
WM24 Floor leakage alarm device Page (544-05) Floor standing detector , compact unit Without moving parts Built-in relay Cable output, 5 m long PVC cable Created on 22/12/2008 18:30 and updated on 10/04/2018 14:08 |
544-05 Page |
IFAT 2008 - Munich 5-9 May 2008 15th International Trade Fair for Water - Sewage - Refuse - Recycling News () It was once more a successful exhibition "Environmental solutions" with 120000 visitors for 2560 exhibitors. Our booth BAMO-IER in the middle of numerous and talented manufacturers received congratulations from them as well as from visitors. The 2/3 of... Created on 21/12/2009 17:45 and updated on 10/04/2018 16:22 |
News |
GsM 24e Modem GSM / GPRS Starting Up Notice (248-01)
Created on 28/10/2010 16:25 and updated on 10/04/2018 15:21 |
248-01 Starting Up Notice |
VP2V S4-PVC Pneumatically actuated 2-way ball valves, single / double acting Starting Up Notice (913-01)
Created on 07/07/2011 14:34 and updated on 10/04/2018 16:01 |
913-01 Starting Up Notice |
Accessories for pneumatic actuators Starting Up Notice (913-10)
Created on 27/12/2011 18:18 and updated on 10/04/2018 16:06 |
913-10 Starting Up Notice |
9337 Immersion probe with built-in temperature sensor Page (130-02) • Protective holder • Built-in temperature sensor Pt100 • Simplified calibration routine • For 1 electrode (PG 13.5 sealing) • Adjustable immersion depth • Fastening by flange or collar • PVC construction Created on 04/12/2019 10:45 and updated on 04/12/2019 10:51 |
130-02 Page |
NIVOSTOP® ECO Float level regulator Page (522-07) • For clear, non-aggressive liquids • Economic model, easy to install • Switching angle: 45° • Regulation between 2 levels • PVC cable, 10 m long Created on 11/12/2019 11:04 and updated on 11/12/2019 11:09 |
522-07 Page |
CDV Flow controllers & indicators, metallic Page (722-02) • Operates in all positions • Flow indicators, plus 1 flow contact • Versions: Stainless steel or brass • Pressure max. 16 bar • Flow ranges from 0.005 up to 150 l/min Created on 17/12/2019 11:48 and updated on 17/12/2019 11:57 |
722-02 Page |
9240 In-line electrode holder for 1 electrode, pH or ORP Page (140-02) In-line electrode holder for pH and ORP electrodes PVC material Various process connections available • Holder for 1 electrode • Construction: in PVC • Spigot ends Ø 25 mm for solvent welding Created on 08/10/2006 23:54 and updated on 04/12/2019 11:27 |
140-02 Page |
MAGTOP Level indicator Starting Up Notice (560-01)
Created on 11/10/2006 17:42 and updated on 10/04/2018 15:46 |
560-01 Starting Up Notice |
BAMOTOP 239 Converter RS 232 / RS 422 - 485 Page (239-01) Bi-directional converter, serial interface (Full Duplex) Quick and easy set up No configuration needed Created on 22/06/2007 17:17 and updated on 10/04/2018 13:47 |
239-01 Page |
MAXIMAT C Compact overfill sensor Starting Up Notice (555-01)
Created on 27/12/2007 16:44 and updated on 10/04/2018 15:42 |
555-01 Starting Up Notice |
J.A.R. Heavy duty Cat & Mouse level indicator Starting Up Notice (582-01)
Created on 13/05/2009 16:46 and updated on 10/04/2018 15:47 |
582-01 Starting Up Notice |
IFAT 2010 New Perspectives for the Environment News () We shall be exhibiting our productsin Munich at IFAT 2010, the world's leading trade fair for water, sewage, waste and raw materials management. September 13-17, 2010 - New Munich trade fair centre. Created on 26/04/2010 11:43 and updated on 10/04/2018 16:19 |
News |
BAMOSOFT Control Water hardness controller Page (376-01) Water hardness controller for water softening systems Set up value from 0.25 to 10% of raw water hardness, 4-20 mA signal output • Fit any water softener system • On-line control and monitoring • Alarm set up from 0.25% to 10% of raw water... Created on 10/12/2010 08:53 and updated on 04/02/2022 12:14 |
376-01 Page |
VP3V S4-PPH Pneumatically actuated 3-way ball valves, single / double acting Page (913-05) ND 10 to ND 50 In-line pattern Pneumatic actuator Single or double acting, Position index Status NC or NO Created on 08/12/2011 10:03 and updated on 10/04/2018 14:39 |
913-05 Page |
VE2V S4-PVDF Electrically actuated 2-way ball valves Starting Up Notice (914-07)
Created on 28/03/2012 16:52 and updated on 10/04/2018 16:09 |
914-07 Starting Up Notice |
NEON® Monitor for CCK sensor Page (194-06) • Disinfectant measurements with auto-cleaning of sensor • 1 Input for CCK sensor • 1 Relay output • 1 Input for flow controller • OPTIONS: PID with 2 relays, 1 or 2 Analogue outputs 4-20 mA RS485 Interface (Modbus) Created on 10/12/2019 12:47 and updated on 10/12/2019 12:49 |
194-06 Page |
RÉGLETTES Graduated rulers Page (583-20) • High readability • Weather and UV resistance • Thermal transfer printed • Scale units: %, litre, m³, cm, feet, etc. • Black marks on white background • White PVC profile, U shape 70 x 35 mm or L shape width 30 mm Created on 11/12/2019 14:57 and updated on 11/12/2019 14:59 |
583-20 Page |
PDP Small plastic flow indicator Page (731-03)
Created on 17/12/2019 15:59 and updated on 17/12/2019 16:09 |
731-03 Page |
BIF 6040 Flow-rate and totalizer Page (282-01) • For flow-rate sensors • Fast programming • Input signal: NPN, PNP, TTL contact • Low frequencies: from 0.03 up to 30 000 Hz • Main power supply: 95 ... 265 V AC • Display: 6 digits • Resolution: Adjustable • OPTIONS : 2 or 4 alarms on... Created on 09/10/2006 16:28 and updated on 10/12/2019 14:28 |
282-01 Page |
MAXIMAT LW C Leakage detection sensor Page (555-03) Capacitive, high frequency, fail-safe detection For aggressive and conductive liquids Positive active alarm Auto diagnostic system and LED indicator Approvals: DIBT Z-65.40-316, for overfilling detection WHG§19 Created on 13/02/2007 14:53 and updated on 10/04/2018 14:11 |
555-03 Page |
STE Level control with resistive probes Page (540-01) Resistive level probe 1 up to 5 electrodes Rods are in stainless steel or titanium For all conductive liquids From 1 to 5 electrodes All motionless parts Adjustable lengths on site Maximum pressure 15 bar Maximum temperature 110°C Process connections... Created on 03/04/2007 18:21 and updated on 10/04/2018 14:04 |
540-01 Page |
9200 pH or ORP continious flow cells Starting Up Notice (140-01)
Created on 06/08/2007 17:42 and updated on 10/04/2018 15:17 |
140-01 Starting Up Notice |
MAXIMAT LWC-B Leakage detection sensor Starting Up Notice (555-05)
Created on 22/10/2008 15:40 and updated on 10/04/2018 15:43 |
555-05 Starting Up Notice |
9346 pH - ORP Immersion probe Starting Up Notice (135-01)
Created on 04/12/2009 14:11 and updated on 10/04/2018 15:16 |
135-01 Starting Up Notice |
PES7 Peracetic acid sensor Page (193-30) - Disinfection process in food industry - Ranges: 0 ... 0.2 /... 0.5 /... 1 /... 2 g/l - Unnecessary zero adjustment - Only 1 point requested for calibration Created on 27/09/2010 16:58 and updated on 04/12/2019 17:08 |
193-30 Page |
TS 18 Ambient temperature probe Page (618-01) • Sensor: Pt 100 Ω at 0 °C • Range: From -40 °C up to +75 °C • Wall mount ABS housing • Output signal: Or resistor or 4-20 mA Created on 04/01/2011 17:46 and updated on 11/12/2019 16:52 |
618-01 Page |
VEP K4-PVDF Electrically actuated butterfly valves Page (914-09) • Butterfly valves ND50 to ND200 • Radial mounting and dismounting • Electric actuator with position pointer and manual operating for emergency Created on 08/12/2011 17:38 and updated on 18/12/2019 15:24 |
914-09 Page |
BCP 48 Programmable Counter / Downcounter Page (289-03) • Versatile and simple • Dual back-lighted display: Totalizer 8 digits Batch counter 6 digits • 2 presets with relay outputs • 4 counting modes • Sensor power supply: 12 ... 26 V DC • Panel mounting, 48 x 48 mm, DIN Created on 10/12/2019 14:29 and updated on 10/12/2019 14:33 |
289-03 Page |
CDP 57 Paddle flow controllers Page (710-02) • For clear liquids • Stainless steel or brass versions • For pipes from ND 50 up to ND 200 • Mounting on-line, fitting with loose nut BSPF ½'' Created on 17/12/2019 10:12 and updated on 17/12/2019 10:21 |
710-02 Page |
MF-3V Operating modes for 3-way ball valves Page (913-20) Our 3-way ball valves are supplied in a standard operating mode according to anti-clocwise movement (rotation 90°) Created on 18/12/2019 11:40 and updated on 18/12/2019 11:42 |
913-20 Page |
ES 2001 Resistive level detector Page (530-01) Level control relay For electrically conductive liquids On/Off level controller using 2 rods Level regulation using 3 rods Pump automation, protection Alarm signals • For all electrically conductive liquids • Adjustable sensitivity, timer;... Created on 10/10/2006 16:13 and updated on 11/12/2019 12:51 |
530-01 Page |
BAMOX 7200 Dissolved oxygen sensor Page (460-02) Galvanic dissolved oxygen sensor Sturdy construction Easy fitting and maintenance Range: 0...20 ppm (0-100%) Large electrolyte volume Easy membrane replacement HDPE membrane Built in temperature sensor: Pt 100 Ohm / 0°C Construction: POM Created on 07/06/2007 11:47 and updated on 10/04/2018 14:00 |
460-02 Page |